Description
1. Introduction
The Obturation stylet 14G x 50 mm Vasofix Safety from B. Braun (Ref. 4219201) is the essential component for keeping a large-bore peripheral intravenous catheter in place when there is no active infusion. It prevents the line from becoming occluded or contaminated between administrations, reduces the need for new punctures and protects both the patient and healthcare staff. Verified in the manufacturer’s official catalogue under the designation MANDRIN/STYLET VASOFIX 14G (2.2 x 50 mm, orange colour), it is supplied in an individual sterile pack and a box of 50 single-use units. A practical and cost-effective solution for emergency departments, surgery, resuscitation, ICU and oncology, where the line remains in place for hours or days and high infusion flows are required.
2. Technical explanation of the procedure
In peripheral intravenous cannulation, the stylet or mandrel has a dual function. During puncture, the internal needle guides the introduction of the catheter through the skin and the vein wall; once venous return is confirmed, it is removed and the polyurethane catheter remains implanted. When infusion is interrupted, the stylet acts as an obturator: when inserted into the lumen it seals it hermetically via its Luer Lock connector, prevents blood reflux into the lumen, prevents the formation of thrombi and obstructions and maintains the asepsis of the circuit without the need for heparinisation or removal of the line. To resume therapy, the clinician removes the stylet and reconnects the infusion line.
Reference 4219201 corresponds to gauge 14G (2.2 mm outer diameter) with a length of 50 mm, designed for the 50 mm catheters of the Vasofix Safety family. Its orange colour code, in accordance with the ISO 10555-5 coding, matches that of the catheter it accompanies, facilitating rapid identification on the dressing trolley and preventing gauge errors.
3. Technical Specifications
| Characteristic | Specification |
| Manufacturer / Series | B. Braun – Vasofix Safety (obturator stylet) |
| Manufacturer reference | 4219201 (EAN 4022495007902) |
| Product type | Obturator stylet for peripheral catheter |
| Gauge | 14G (2.2 mm outer diameter) – orange colour code (ISO 10555-5) |
| Length | 50 mm |
| Connection | Luer Lock (hermetic lumen seal) |
| Clinical function | Temporary interruption of infusion/transfusion; prevents thrombi, obstructions and reflux |
| Compatibility | Vasofix, Vasocan and Braunüle Catheters |
| Material | High-quality surgical stainless steel |
| Sterility | Yes, sterile (ethylene oxide) |
| Use | Single-use / disposable |
| Presentation | Individual sterile packaging · Box of 50 units |
Vasofix Safety mandrel family (B. Braun):
| Reference | Gauge | Length |
| 4219201 | 14G (2.2 mm) | 50 mm |
| 4219171 | 16G (1.7 mm) | 50 mm |
| 4219139 | 18G (1.3 mm) | 33 mm |
| 4219120 | 18G (1.3 mm) | 45 mm |
| 4219104 | 20G (1.1 mm) | 33 mm |
| 4215095 | 22G (0.9 mm) | 25 mm |
4. Equivalences and Cross-References
Reference 4219201 has been verified in the manufacturer’s official catalogue B. Braun (Vasofix stylet series, CI50 presentation) and in independent authorised distribution sources, so the code is considered valid.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun | Introcan (obturator stylet) | 4214218 | Comparable by category (not interchangeable 1:1) | Gauge 14G and length 2″ (50.8 mm) very close, but Introcan catheter system with a different cone geometry to Vasofix; verify compatibility before replacing. |
| B. Braun | Vasofix Safety (obturator stylet) | 4219171 | Comparable by category (not interchangeable 1:1) | Same family and length 50 mm but gauge 16G (1.7 mm); indicated for smaller-gauge catheters. |
| B. Braun | Introcan (obturator stylet) | 4214170 | Comparable by category (not interchangeable 1:1) | Gauge 16G and length 2″ (50.8 mm); belongs to the Introcan system, not the Vasofix system. |
There is no equivalence table validated by the manufacturer that allows this stylet to be replaced 1:1 by a stylet from another brand with documentary warranty; consult the technical department before use in tenders. The homologous families of safety catheters from other manufacturers (Venflon Pro Safety and Insyte Autoguard from BD, SafeTouch from Nipro, Leaderflex from Vygon or Intuitiv from ICU Medical) integrate the obturation into the catheter itself (blood control septum or internal needle), so they are not interchangeable 1:1 with this independent stylet.
5. Selection tips and variants of interest
Always select a stylet of the same gauge as the cannulated catheter and with a length matching that of the catheter: for a 14G 50 mm catheter use this reference 4219201. If your protocol uses catheters of other gauges, the Vasofix Safety range offers: 4219171 (16G x 50 mm), 4219139 (18G x 33 mm), 4219120 (18G x 45 mm), 4219104 (20G x 33 mm) and 4215095 (22G x 25 mm). For the Introcan Safety system, reference 4214218 (14G, 2″) is available. At Cahnos you will also find the corresponding Vasofix Safety catheters (homologous catheter G14 x 50 mm, Ref. 4269225S-01) and the rest of the peripheral venous puncture material. Check the integrity of the packaging and the sterility expiry date before each use, follow aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.



Reviews