Description
1. Introduction
The Introcan W Safety Braun G18 1.3 × 32 mm Winged Safety Catheter (ref. 4253604-01) is the reference solution for safe, rapid and reliable peripheral venous access in adult patients. It combines the passive safety technology of the Braun Introcan system with a polyurethane (PUR) catheter body that reduces venous wall irritation and allows stable cannulation. It is a single-use, sterile product designed for hospitalisation, emergency departments, operating theatres, transfusion units and any service where protection of healthcare staff and reliability of access are priorities.
2. Technical explanation of the procedure
The Introcan W Safety catheter is introduced into the vein using a controlled single-step puncture technique. Its hub with fixation wings allows a firm, ergonomic grip, facilitating stabilisation of the assembly during cannulation and subsequent fixation with a dressing. Once the needle is withdrawn from the catheter, the passive self-activating safety mechanism (protection clip) automatically encapsulates the needle tip within the device, requiring no additional action from the professional: this eliminates exposure to the contaminated needle and minimises the risk of accidental needlestick injury, in line with European regulations on the prevention of biological accidents. The polyurethane (PUR) material offers greater intravascular flexibility, lower thrombogenicity and better tolerance in prolonged access. The G18 gauge (external diameter 1.3 mm) provides a high flow rate of 105 ml/min, suitable for transfusions, high-volume infusions and contrast administration.
3. Technical Specifications
| Manufacturer / Series | Braun – Introcan Safety-W (Introcan W Safety) |
| Manufacturer reference | 4253604-01 |
| Product type | Peripheral intravenous safety catheter with wings (winged) |
| Gauge | 18G (external Ø 1.30 mm; internal Ø 1.00 mm) |
| Usable length | 32 mm |
| Maximum flow rate | 105 ml/min |
| Catheter material | Polyurethane (PUR) |
| Colour code | Green (ISO 10555-5) |
| Connection | Female Luer-Lock |
| Injection port | No |
| Safety system | Passive, auto-activation (needle protection clip) |
| Design | With fixation wings for stability and fixation |
| Presentation | Box of 50 units, sterile, single-use |
| Main indication | Adult; transfusions, high-flow infusions and contrast administration |
Introcan Safety-W family with wings (Braun)
| Reference | Gauge | Size (Ø × length) |
| 4251614-01 | 24G | 0.7 × 14 mm |
| 4253523-01 | 24G | 0.7 × 19 mm |
| 4253540-01 | 22G | 0.9 × 25 mm |
| 4253566-01 | 20G | 1.1 × 32 mm |
| 4253604-01 | 18G | 1.3 × 32 mm |
| 4253590-01 | 18G | 1.3 × 45 mm |
| 4253612-01 | 16G | 1.7 × 50 mm |
| 4253639-01 | 14G | 2.2 × 50 mm |
4. Equivalences and Cross-References
Reference 4253604-01 has been verified in the official Braun catalogue as Introcan Safety-W PUR 18G, 1.3 × 32 mm, with a flow rate of 105 ml/min, female Luer-Lock connection, green colour and safety clip, so the code is considered valid. The concept of a winged safety catheter is shared by several manufacturers, but there is no manufacturer-validated equivalence table between safety catheters from different manufacturers: differences in safety mechanism (active button retraction vs. passive self-activation), catheter material, useful length and bevel geometry prevent 1:1 interchangeability without prior clinical validation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| BD | Insyte Autoguard Winged (Vialon) | 381544 | Comparable by category (not interchangeable 1:1) | 18G × 1.16″ (30 mm); active button retraction vs. passive self-activation; length 2 mm shorter; flow rate 105 ml/min (verified on official BD website). |
| BD | Insyte Autoguard Shielded (Vialon) | 381444 | Comparable by category (not interchangeable 1:1) | 18G × 1.16″ (30 mm) without wings; button mechanism; same base size but without fixation wings (verified on official BD website). |
There is no manufacturer-validated equivalence table between this catheter and safety systems from other manufacturers; consult the technical department before use in tenders. Comparable homologous families of winged safety catheters by category (not interchangeable 1:1) include: Venflon Pro Safety (BD), Surflo W / Surflash W (Terumo), SafeTouch (Nipro) and Leaderflex (Vygon). In all cases, gauge, length, material, flow rate and safety mechanism must be verified in the manufacturer’s technical data sheet before any substitution; their specific codes for G18 could not be cross-checked in public sources and must be confirmed with the manufacturer before use.
5. Selection tips and variants of interest
Always select the gauge and length appropriate to the venous territory and type of therapy: this G18 of 32 mm (ref. 4253604-01) is the standard adult option for transfusions and high-volume infusions; if a longer intravascular path is needed while maintaining the same gauge, the G18 45 mm variant (ref. 4253590-01) is the alternative; for conventional infusion therapies, drop to G20 (4253566-01) or G22 (4253540-01) and for paediatric patients or fine veins use G24 (4251614-01 or 4253523-01). For maximum flow in critically ill patients, consider G16 (4253612-01) or G14 (4253639-01). Complete your stock with the obturation stylets from the Introcan family (ref. 4214xxx) to maintain the cannulated line between administrations without risk of occlusion. Always verify the integrity of the packaging and the sterility expiry date before each use, respect aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.





Reviews