Description
1. Introduction
The SafSite® Connector Ref. 4091000 is the needle-free intravenous access solution from the B. Braun infusion family, designed to simplify and make safer the administration of intravenous therapies in hospitals, clinics and healthcare centres. Its two-way valve system allows injection, infusion and sample extraction through the same access point, keeping the circuit closed and protected against contamination. It is the usual choice in hospitalisation, emergency, ICU, oncology and intensive care services where prevention of catheter-associated bloodstream infections (CRBSI) and protection of healthcare staff against accidental needlestick injuries are priorities.
2. Technical explanation
The SafSite® is a needle-free (without needle) connector with an internal two-way valve mechanism: when inserting a syringe, three-way stopcock or infusion set with standard Luer connector, the valve opens and allows fluid to pass in both directions (injection and extraction); when the device is removed, the valve closes automatically, maintaining the integrity of the closed system and preventing leaks or reflux. This technology eliminates the need for needles to access the venous line, reducing accidental needlesticks, manipulation of the circuit and entry points for microorganisms. The high-flow design facilitates rapid drug administration, continuous infusion and blood sample collection with low resistance, being compatible with the standard Luer connection of most equipment, extension lines and catheters on the market.
3. Technical Specifications
| Parameter | Specification |
| Official reference | 4091000 (factory code B. Braun) |
| Device type | Needle-free connector for intravenous access |
| Closure system | Two-way valve, automatic sealing when the connector is removed |
| Activation | By insertion of standard Luer connector (male/female) |
| Function | Injection, infusion and sample extraction through the same access |
| Flow rate | High flow rate, low flow resistance |
| Use | Single-use (disposable), sterile |
| Compatibility | Infusion sets, extension lines, three-way stopcocks and catheters with standard Luer connection |
| Indications | Drug administration, intravenous therapy, infusion and sample collection |
| Presentation | Box of 50 units |
Data according to the manufacturer’s official technical data sheet: connector for needle-free intravenous access with two-way valve system.
4. Equivalences and Cross-References
This connector belongs to the family of needle-free connectors for closed infusion systems. No official equivalence table validated by the manufacturer has been found that cross-references the 4091000 reference with codes from other manufacturers; the following correspondences are functional comparisons by category verified against official catalogues and authorised distribution, and should not be treated as 1:1 interchangeable without validation from the technical department. Within the B. Braun family itself, the same SafSite® valve is marketed in other markets as 415067 (with replacement cap) and 415068 / RV1000NC (without cap), and there is the Safeflow® variant (ref. 409100H) with split-septum technology that shares the indication but differs in the sealing mechanism.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| BD (Becton Dickinson) | Q-Syte™ needle-free connector with split septum | 385100 (SKU Cahnos: GM26058) | Comparable by category (not interchangeable 1:1) | Needle-free connector with split septum, straight fluid path and high flow rate, DEHP-free and latex-free; box of 50 units. The sealing mechanism (split septum vs. two-way valve) and geometry differ. Code verified in authorised distribution. |
| Vygon | Vadsite® needle-free connector / closed system | Consult official catalogue | Comparable by category (not interchangeable 1:1) | Same clinical indication (needle-free access in closed system); verify opening pressure, priming volume and connection in the technical data sheet before replacing. |
| ICU Medical | Clave® needle-free connectors / closed system | Consult official catalogue | Comparable by category (not interchangeable 1:1) | Homologous family of needle-free connectors; confirm sealing mechanism and Luer compatibility with the circuit in use. |
There is no equivalence table validated by the manufacturer; consult the Cahnos technical department before using in tendering or replacement of material in use.
5. Selection tips and variants of interest
Select the SafSite® connector when your protocol requires a needle-free access point with two-way flow (injection and extraction) in a closed system, with emphasis on infection prevention and protection of healthcare staff against needlesticks. For lines working with split-septum technology, the same company offers the Safeflow® variant (ref. 409100H); if your priority is a high-volume format with optimised cost, consider the closed-system Luer Lock valves from the Cahnos catalogue (VALBDDN bidirectional 60 PSI, VALARB non-return 0.3 PSI and VALASB anti-siphon 3.5 PSI) and the BD Q-Syte™ connector (GM26058). Always disinfect the access surface with an appropriate antiseptic before each connection, respect the maximum use time indicated in the manufacturer’s instructions and complete the circuit with extension lines, three-way stopcocks and standard Luer connection catheters. For volume purchases, hospital supplies or tenders, contact the technical-commercial team at Cahnos.




Reviews