SPRING-CUT® – Semi-automatic soft tissue biopsy needle, non-magnetic and MRI-safe. Tru-Cut guillotine system

Price on request

SPRING-CUT® is the semi-automatic guillotine-type biopsy needle for soft tissue manufactured with non-magnetic components, 100% safe for magnetic resonance imaging. It incorporates a stylet advance button locked during penetration, a preset biopsy throw of 10-20 mm and a fully retractable stylet for sample control and multiple biopsies (prostate mapping). Sterile, single-use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAHSPRING-CUT

Description

SPRING-CUT® represents the latest generation of semi-automatic guillotine-type biopsy needles for soft tissue, designed with a key differentiating feature: its construction with non-magnetic materials makes it completely safe for use in magnetic resonance imaging (MRI). Designed for interventional radiology, diagnostic imaging and urology departments, it combines cutting precision, single-handed operation and maximum diagnostic reliability in a sterile, single-use device.

Technical explanation of the device and procedure

The semi-automatic SPRING-CUT® needle works via a spring-loaded Tru-Cut-type guillotine system: the professional cocks the device, positions it under image guidance and triggers the firing so that the cutting cannula captures the sample in the stylet’s extraction notch. Its exclusive design keeps the stylet advance button locked during penetration, which simplifies the manoeuvre, increases procedure safety and improves sensitivity during advancement through tissue. The biopsy throw is preset in a range of 10-20 mm, adapting to the lesion size, and the stylet can be fully retracted from the cannula left in situ, allowing verification of sample adequacy and multiple sampling through a single access, such as in prostate mapping. As the components are non-magnetic, the needle does not interfere with the scanner’s magnetic field and can be used with complete safety in MRI equipment.

Technical specifications

Parameter Specification
Reference CAHSPRING-CUT
Mechanism type Semi-automatic guillotine type (Tru-Cut)
Biopsy throw Preset 10-20 mm, depending on lesion size
Advance manoeuvre Stylet advance button locked during penetration
Stylet Fully retractable from the cannula left in situ
MRI safety Non-magnetic, MRI-safe
Cutting mechanism Powerful, reliable cutting in dense tissue
Handling Single-handed, compatible with image guidance
Sterility Sterile, single-use

SPRING-CUT range variants (related references)

Reference Gauge Available lengths
SPRINGCUT14 14G (2.00 mm) 11, 15, 20, 25 and 47 cm
SPRINGCUT16 16G (1.60 mm) 11, 15, 20, 25 and 47 cm
SPRINGCUT18 18G (1.20 mm) 11, 15, 20 and 25 cm
SPRINGCUT20 20G (0.90 mm) 11, 15, 20 and 25 cm

Equivalences and cross-references

SPRING-CUT® belongs to the family of semi-automatic Tru-Cut-type needles for soft tissue, comparable to reference core biopsy systems such as the Original TEMNO and Achieve (CareFusion/BD) or the needles for the automatic Magnum and TruGuide guns from Bard/BD, as well as the FAST-CUT system from Sterylab. Compared to automatic double-firing systems, its semi-automatic mechanism offers finer control in image-guided procedures. In the Cahnos catalogue, the non-magnetic version for MRI finds its equivalent in the BIO-CUT® needle (ref. CAHBIOCUT), while the complete semi-automatic range comprises the references SPRINGCUT14, SPRINGCUT16, SPRINGCUT18 and SPRINGCUT20 (Sterylab S.r.l., Rho, Milan, Italy). For manual operation, references BIOCUT14 to BIOCUT20 are available and, for automatic cutting, the COLT14 to COLT20 range.

Selection tips and variants of interest

Select the gauge according to the target organ and required sample volume: 14G for deep lesions requiring abundant tissue (breast, liver, kidney, prostate), 16G as a balance between sample and tissue aggressiveness, 18G for thyroid, lymph nodes and soft parts, and 20G for small nodules. The length should be chosen based on the depth of the lesion and the access route (11 cm for superficial lesions; 15-20 cm for medium depth; 25 cm or more for deep or special accesses). For multiple sampling through a single access, consider the version with removable cannula (SPRING-CUT DC); for CT guidance, the coaxial set (SPRING-CUT SET-TAC); and if you require maximum ultrasound visualisation or more abundant samples, consult the PLUS+ (ECHONOX alloy) and PLUS++ (TOP-CORE geometry) versions. Contact our technical-commercial team to confirm the most suitable reference for your specialty and supply volume.

Additional information

Mechanism type

Semi-automatic guillotine type (Tru-Cut)

MRI safety

Non-magnetic, MRI-safe

Biopsy throw

Preset 10-20 mm

Stylet

Fully retractable from the cannula left in situ

Handling

Single-handed, compatible with image guidance

Material

Non-magnetic medical-grade components

Sterilisation

Sterile, single-use