Description
The modified Menghini cutting needle with total recovery 20G is the reference solution for interventional radiology, pathology, gastroenterology and oncology departments that need to obtain complete and reliable diagnostic samples with a minimally invasive procedure. Available in lengths of 9, 11, 15 and 20 cm, it adapts to the depth of the lesion and the technique used, ensuring total sample extraction with minimal trauma to the patient.
Technical explanation of the device and procedure
This needle follows the classic modified Menghini design, an international reference in aspiration biopsy. Its tip has an ultra-sharp bevel that allows clean tissue penetration without tearing, preserving the integrity of the sample for reliable histopathological diagnosis. The IFR® total recovery system retrieves from the cannula lumen and the syringe all the cells that are normally lost during puncture, maximising diagnostic yield.
Its technical advantages include dual sample collection (cytological and microhistological) with a single puncture, echoreflective stainless steel that allows complete ultrasound visualisation without the risk of malignant cell dissemination by conventional markers, and vacuum assistance that facilitates aspiration. The centimetre markings and sliding stop allow precise depth control during the procedure.
Technical specifications
Made from high-quality stainless steel, it is a sterile, single-use product, individually packaged and supplied in boxes of 10 units.
| Gauge | External diameter (mm) | Available lengths (cm) | Packaging |
|---|---|---|---|
| 16G | 1.60 | 9 – 11 – 15 – 20 | Box of 10 units |
| 17G | 1.40 | 9 – 11 – 15 – 20 | Box of 10 units |
| 18G | 1.20 | 9 – 11 – 15 – 20 | Box of 10 units |
| 19G | 1.05 | 9 – 11 – 15 – 20 | Box of 10 units |
| 20G | 0.90 | 9 – 11 – 15 – 20 | Box of 10 units |
| 21G | 0.80 | 9 – 11 – 15 – 20 | Box of 10 units |
| 22G | 0.70 | 9 – 11 – 15 – 20 | Box of 10 units |
Also available in CT version (coaxial procedures guided by tomography), consisting of the needle and a special guide needle.
| Configuration | Example order code |
|---|---|
| Full-Opty 20G – 15 cm | FLP2015 |
| Set-TAC (coaxial) 20G – 15 cm | FLP2015T |
- Gauge: 20G (0.90 mm outer diameter).
- Tip: modified Menghini cutting with ultra-sharp bevel.
- System: IFR® total recovery with dual cytological and microhistological sampling.
- Material: echoreflective stainless steel.
- Sterility: sterile, disposable, single-use.
- Applications: percutaneous liver biopsy and soft tissue biopsy.
Equivalences and cross-references
This needle belongs to the Full-Opty® range from Sterylab (Italy), within the family of modified Menghini cutting needles with total recovery of biopsied cells (IFR®). In the Cahnos catalogue, the equivalent standard reference in 20G is FULLOPTY20, while the FULLOPTY20-B variant is distinguished by its specific commercial configuration. Alternatives from the same family include the modified Menghini cutting needles in other gauges: FULLOPTY16, FULLOPTY17, FULLOPTY18, FULLOPTY19, FULLOPTY21 and FULLOPTY22. For Gelman-type aspiration biopsy (also modified Menghini), the ATACUT series is available (e.g., ATACUT20 in 20G) and the liver biopsy sets according to the Menghini method from the HEPACUT series. Please consult our technical-commercial department to validate the correspondence with your usual supply brand.
Selection tips and variants of interest
Select the 9 cm length for superficial lesions and short approaches, the 11 cm as the standard option for percutaneous liver biopsy, the 15 cm for patients with greater adipose panniculus, and the 20 cm for deep lesions or longer approaches. If you perform the procedure under computed tomography, consider the SET-TAC version with coaxial guide needle for a safe and controlled approach. For small or hard-to-reach lesions, a Chiba-type needle or an automatic biopsy gun system with echogenic marker may be more suitable, also available in our catalogue. Our technical-commercial team is at your disposal to help you configure the gauge and length best suited to your biopsy protocol and hospital purchasing policy.







Reviews