Gelman-type Biopsy Needle (Modified Menghini) 16G | ATA-CUT Series | Lengths 9, 11 and 15 cm | Sterile and Disposable (Ref. ATACUT16)

Price on request

Gelman-type biopsy needle (modified Menghini) 16G gauge, reference ATACUT16 from the ATA-CUT series. Available in lengths of 9, 11 and 15 cm, it is designed for the precise collection of histological samples by suction in percutaneous soft tissue biopsy and liver biopsy. It incorporates an ultra-sharp cutting edge and a trocar-tipped stylet that ensure clean, controlled penetration with minimal trauma, preserving the integrity of the sample. Made from high-quality stainless steel, it is sterile, disposable and single-use, ideal for interventional radiology, oncology, gastroenterology and surgery.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ATACUT16

Description

The Gelman-type biopsy needle (modified Menghini) 16G from the ATA-CUT series (Ref. ATACUT16) is the reference solution for interventional radiology, oncology, gastroenterology and surgery departments that need to obtain high-quality histological samples with a minimally invasive procedure. Available in lengths of 9, 11 and 15 cm, it adapts to the depth of the lesion and the technique used in each clinical case, becoming a versatile and reliable tool to optimise the diagnostic yield of your percutaneous biopsy service.

Technical explanation of the device and procedure

This needle follows the classic Gelman design, considered a variant of the modified Menghini needle for aspiration, a worldwide reference for obtaining histological and cytological samples from the liver and soft tissues. It incorporates a ultra-sharp cutting edge that allows clean tissue penetration without tearing, preserving the integrity of the sample for reliable histopathological diagnosis, and a trocar-tipped stylet that facilitates controlled advancement to the lesion. The ultra-thin wall cannula optimises suction and improves sample yield.

The procedure involves inserting the needle under ultrasound or CT guidance, applying suction and extracting the tissue cylinder in a single manoeuvre, minimising patient trauma and maximising diagnostic yield. The 16G gauge (1.60 mm outer diameter) offers the largest diameter in the ATA-CUT range, ideal when a large and representative tissue cylinder is required.

Technical specifications

Parameter Specification
Reference ATACUT16
Needle type Gelman-type biopsy (modified Menghini) by suction
Gauge 16G (1.60 mm outer diameter)
Available lengths 9 cm, 11 cm and 15 cm
Tip Ultra-sharp cutting
Mandrel Trocar point
Design Minimises trauma and improves sample quality
Material High-quality stainless steel that ensures control and durability
Sterility Sterile, disposable, single-use
Presentation Individual sterile packaging
Applications Percutaneous liver biopsy and soft tissue biopsy

The ATA-CUT range is available in several gauges to suit each biopsy protocol:

Gauge External diameter (mm) Available lengths (cm)
16G 1.60 9 – 11 – 15
17G 1.40 9 – 11 – 15
18G 1.20 9 – 11 – 15
19G 1.05 11 – 15 – 20
20G 0.90 11 – 15 – 20
21G 0.80 11 – 15 – 20

Equivalences and cross-references

This needle belongs to the ATA-CUT range from Sterylab (Italy), within the family of Gelman-type needles (modified Menghini) for suction biopsy. The manufacturer’s ordering codes for the 16G gauge are ATC1609 (9 cm), ATC1611 (11 cm) and ATC1615 (15 cm), with the equivalent Cahnos reference being ATACUT16.

Alternatives from the same family include the FAST-CUT® type B 16G needles for the Magnum automatic biopsy gun (e.g. FSC1615B), the FULL-OPTY series with total IFR® rescue (FULLOPTY16 / FLP1609) and the liver biopsy sets according to the Menghini method from the HEPA-CUT series (HEPACUT16 / HPC1609). Please consult our technical-commercial department to validate the exact correspondence with your usual supply brand and to manage B2B conditions and formalised quotations.

Selection tips and variants of interest

Select the 9 cm length for superficial lesions and short access routes, the 11 cm as the standard option for percutaneous liver biopsy and the 15 cm for deep tissues or patients with a larger adipose panniculus. The 16G gauge offers the largest diameter sample in the ATA-CUT range, being the recommended option when a large and representative tissue cylinder is required for histopathological diagnosis.

The needle is preferably used with the manual suction technique, so it is advisable to have a syringe with automatic locking to maintain constant suction. The ATA-CUT range is also available in 17G, 18G, 19G, 20G and 21G gauges (Refs. ATACUT17, ATACUT18, ATACUT19, ATACUT20 and ATACUT21). For small lesions or difficult-to-access areas, consider using Chiba-type needles or biopsy systems with an automatic gun and echogenic marker, also available in our catalogue. Our technical-commercial team is at your disposal to help you configure the most appropriate gauge and length for your biopsy protocol.

Additional information

Reference

ATACUT16

Manufacturer

Sterylab (ATA-CUT series)

Needle type

Gelman-type biopsy (modified Menghini) by suction

Gauge

16G (1.60 mm outer diameter)

Available lengths

9 cm, 11 cm and 15 cm

Tip

Ultra-sharp cutting

Mandrel

Trocar point

Material

High-quality stainless steel

Sterilisation

Sterile, single-use

Presentation

Individual sterile packaging

Application

Percutaneous liver biopsy and soft tissue biopsy

Reviews

There are no reviews yet.

Be the first to review “Gelman-type Biopsy Needle (Modified Menghini) 16G | ATA-CUT Series | Lengths 9, 11 and 15 cm | Sterile and Disposable (Ref. ATACUT16)”

Your email address will not be published. Required fields are marked *