We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable 23G Chiba needle for sterile cytological biopsy (7, 9, 11, 15 and 20 mm) | Ref. BIOCHIBACPL005

Price on request

Disposable 23G Chiba needle for cytological biopsy, available in lengths of 7, 9, 11, 15 and 20 mm. Its sharp tip and Chiba-type geometry ensure smooth, controlled penetration, minimising tissue trauma and obtaining high diagnostic-quality cell samples with minimal invasion. Sterile single-use presentation for maximum safety and absence of cross-contamination.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BIOCHIBACPL005

Description

The disposable 23G Chiba needle is the reference instrument for obtaining cell samples in cytological biopsies. Designed for professionals seeking precision, safety and reliable diagnostic results, it combines a fine gauge with a sharp Chiba-geometry tip that facilitates controlled tissue access and maximum-quality sample extraction.

Available in lengths of 7, 9, 11, 15 and 20 mm, it adapts to different lesion depths and anatomical areas, making it a versatile and cost-effective solution for hospitals, clinics, diagnostic imaging centres and anatomical pathology laboratories.

Technical explanation of the procedure

The Chiba needle features a long, sharp bevel tip designed to traverse tissues with lower insertion force and a more predictable trajectory. In fine-needle aspiration (FNA) procedures and cytological biopsies guided by ultrasound or CT, the 23G gauge offers an optimal balance between flexibility and rigidity: sufficient to reach the lesion with control and fine enough to reduce bleeding, pain and tissue trauma, preserving the cellular integrity of the sample for subsequent cytological and histopathological analysis.

As a sterile single-use device, the risk of cross-contamination between patients is completely eliminated and maximum safety is guaranteed in every procedure. Its connection hub is compatible with conventional suction systems: Luer syringes and aspiration guns.

Technical specifications

Characteristic Specification
Gauge 23G (0.65 mm approx.)
Tip type Chiba (long sharp bevel)
Available lengths 7, 9, 11, 15 and 20 mm
Presentation Disposable and sterile, single-use
Main use Cytological biopsy, fine-needle aspiration (FNA) and cellular sample aspiration
Compatibility Luer syringes and suction guns
Use environment Hospitals, clinics, diagnostic centres and laboratories
Reference BIOCHIBACPL005

Equivalences and cross-references

This needle belongs to the Cahnos family of disposable Chiba needles for cytological biopsy. The 23G gauge occupies an intermediate position in the range, ideal for delicate accesses with good suction flow. Full range available:

Reference Gauge Lengths (mm)
BIOCHIBACPL001 18G 7, 9, 11, 15, 20, 25 and 35
BIOCHIBACPL002 20G 7, 9, 11, 15, 20, 25 and 35
BIOCHIBACPL003 21G 7, 9, 11, 15, 20 and 25
BIOCHIBACPL004 22G 7, 9, 11, 15, 20 and 25
BIOCHIBACPL005 23G 7, 9, 11, 15 and 20
BIOCHIBACPL006 25G 7, 9 and 11

Its Chiba-type tip geometry makes it comparable to standard cytological biopsy needles on the European market, and it can be used with the same conventional suction and fixation systems. For ultrasound-guided procedures requiring maximum tip visibility, Cahnos offers the echo-reflective Chiba-tip series (BIOCHIBAECHO005) and the disposable echogenic needles CHGA18, CHGA21 and CHGA22. If the procedure requires MRI compatibility, please refer to reference CAHCHIBA (Complete-Chiba® non-magnetic) from the MRI biopsy range.

Selection tips and variants of interest

To choose the most suitable reference, assess the lesion depth and tissue type: the 7 and 9 mm lengths are ideal for superficial or thin lesions, while the 15 and 20 mm lengths offer greater working travel for deeper accesses. The 23G gauge is particularly indicated for delicate accesses (prenatal, thyroid, breast or sensitive tissue biopsy) where the aim is to minimise patient discomfort without compromising a representative cell sample.

If the procedure requires a larger sample volume or deeper tissues, the larger gauges in the range (18G-22G) can be considered. For maximum delicacy applications, the 25G gauge (7, 9 and 11 mm) is the recommended option. Consult our commercial team for availability, quotation conditions and volume orders.

Additional information

Gauge

23G (0.65 mm approx.)

Tip type

Chiba (long sharp bevel)

Available lengths

7, 9, 11, 15 and 20 mm

Presentation

Disposable and sterile, single-use

Intended use

Cytological biopsy, fine-needle aspiration (FNA), aspiration of cell samples

Compatibility

Luer syringes and suction guns

Environment of use

Hospitals, clinics, diagnostic centres and laboratories

Reference

BIOCHIBACPL005

Categories

Disposable Chiba Needle, Cytological, Biopsy, Prenatal Biopsy

Reviews

There are no reviews yet.

Be the first to review “Disposable 23G Chiba needle for sterile cytological biopsy (7, 9, 11, 15 and 20 mm) | Ref. BIOCHIBACPL005”