Description
1. Commercial Introduction
Cutaneous biopsy punches are the reference solution for taking tissue samples quickly, reliably and with maximum hygiene. Sterilised and ready to use, they completely eliminate the sharpening and sterilisation operations typical of reusable instruments, resulting in time savings in the clinic and the elimination of the risk of cross-contamination. With a wide range of diameters covering 1 to 8 mm, they offer the appropriate gauge for each lesion and each specialty: dermatology, gynaecology and podiatry.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the entire skin, including complete epidermis and dermis for histopathological study. The circular, seamless stainless steel cutting edge provides a constantly smooth and regular cutting surface, allowing a clean incision with minimal damage to the surrounding tissue and optimal specimen quality.
The grooved handle offers a secure grip and precise control during rotation of the instrument, while the diameter embossed on each punch facilitates immediate identification, avoiding errors in the operating theatre or clinic. Each unit is supplied in an individual heat-sealed, transparent peel-apart packaging, guaranteeing sterility until the moment of opening. The box and instructions are multilingual (GB, FR, IT, ES, PT, DE, PL, GR, RU, FI, SE, NL, RO, BG, HR, HU, NO and Arabic), adapted for European distribution.
3. Technical Specifications
Available references
| Reference | Diameter | Sales unit | Details |
|---|---|---|---|
| GM22580 | 1 mm | Box of 10 units | Biopsy punch: Ø 1 mm · Blade length: 8 mm |
| GM22581 | 1.5 mm | Box of 10 units | Biopsy punch: Ø 1.5 mm · Blade length: 8 mm |
| GM22582 | 2 mm | Box of 10 units | Biopsy punch: Ø 2 mm · Blade length: 8 mm |
| GM22583 | 2.5 mm | Box of 10 units | Biopsy punch: Ø 2.5 mm · Blade length: 8 mm |
| GM22584 | 3 mm | Box of 10 units | Biopsy punch: Ø 3 mm · Blade length: 8 mm |
| GM22585 | 3.5 mm | Box of 10 units | Biopsy punch: Ø 3.5 mm · Blade length: 8 mm |
| GM22586 | 4 mm | Box of 10 units | Biopsy punch: Ø 4 mm · Blade length: 8 mm |
| GM22587 | 5 mm | Box of 10 units | Biopsy punch: Ø 5 mm · Blade length: 8 mm |
| GM22588 | 6 mm | Box of 10 units | Biopsy punch: Ø 6 mm · Blade length: 8 mm |
| GM22589 | 7 mm | Box of 10 units | Biopsy punch: Ø 7 mm · Blade length: 8 mm |
| GM22590 | 8 mm | Box of 10 units | Biopsy punch: Ø 8 mm · Blade length: 8 mm |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 10 units |
| Blade material | Seamless stainless steel, sharp edge |
| Handle | Grooved (striated), firm and controlled grip |
| Identification | Size embossed on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual heat-sealed transparent peel-apart packaging |
| Use | Disposable, single-use |
| Clinical areas | Dermatology, gynaecology and podiatry |
| Languages of box and instructions | GB, FR, IT, ES, PT, DE, PL, GR, RU, FI, SE, NL, RO, BG, HR, HU, NO, Arabic |
| Device type | Medical device |
| Device class | II A |
| CND | A010299 |
4. Equivalences and Cross-References
This family of biopsy punches shares the same technical principle as the sterile single-use cutaneous biopsy punches from the main manufacturers on the market: circular seamless stainless steel cutting edge, grooved handle with fine grip, size embossed on each unit and individual sterile presentation. The cross-references indicated are category comparisons, verified against official catalogues and regulatory sources (GUDID); as they are different manufacturers, they are not interchangeable 1:1 and must be confirmed with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| KAI Medical | Sterile Biopsy Punch | BP-30F, BP-40F, BP-50F, BP-60F, BP-80F | Comparable by category (not interchangeable 1:1) |
| Stiefel (GSK-Stiefel) | Stiefel Biopsy Punch | STIEF-BP3, SZ1984, SZ1985, SZ1986, SZ1988 | Comparable by category (not interchangeable 1:1) |
| Integra Miltex | Sterile Disposable Biopsy Punch | 33-32, 33-34, 33-35, 33-36, 33-37 | Comparable by category (not interchangeable 1:1) |
| (KAI line) | Biopsy Punches | 22605, 22614 | Comparable by category (same manufacturer, different line) |
5. Selection tips and variants of interest
The diameter of the punch determines the size of the sample and must be chosen according to the lesion and the intended histopathological study:
- 1–2 mm: very small lesions, mucous membranes and paediatric patients, minimising scarring.
- 2.5–3.5 mm: small lesions and aesthetic areas; usual range with contained cosmetic defect.
- 4–5 mm: standard range in dermatology for most skin lesions, with a highly representative sample.
- 6–8 mm: large lesions or studies requiring a large sample with complete epidermis and dermis.
Keep the full range of diameters in the department to cover any indication with the same supplier and quality. Check the integrity of the individual packaging before each use and dispose of the instrument after the procedure in accordance with healthcare waste regulations. For large orders you can request a quote: consult your technical-commercial advisor at Cahnos for terms and delivery times.















Reviews
There are no reviews yet.