1. Commercial Introduction
The 4 mm Ø skin biopsy punch with plunger, from the KAI line manufactured in Japan, is the reference instrument for obtaining tissue samples quickly, reliably and with maximum hygiene in dermatology, gynaecology and podiatry consultations. Its very sharp circular stainless steel cutting edge allows a 4 mm cylindrical sample to be taken with a clean, regular cut and minimal trauma to the surrounding tissue, promoting rapid healing and a reliable histopathological report. As a sterile, single-use medical device, it completely eliminates the sharpening and sterilisation operations typical of reusable instruments, as well as the risk of cross-contamination.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the entire skin, including complete epidermis and dermis for histopathological examination. The very sharp circular stainless steel cutting edge provides a smooth, regular cutting surface, allowing a clean incision with optimal specimen quality.
The distinctive feature of this reference is its plunger: after rotating the punch and making the circular incision, the plunger facilitates the removal and collection of the cylindrical sample, simplifying the extraction manoeuvre and avoiding damage to the tissue obtained. The fluted handle ensures a firm grip and precise control during rotation, even with gloves, while the size printed on each unit allows immediate identification, preventing errors during the procedure. Each punch is individually sealed in a transparent peel-apart package, guaranteeing sterility until the moment of opening. It is a disposable, single-use device.
3. Technical Specifications
Disposable skin biopsy punch, Ø 4 mm, with plunger, with a blade length of 7 mm, very sharp stainless steel cutting edge and fluted handle. Size printed on each unit for easy identification. Indicated for dermatology, gynaecology and podiatry. Each punch is individually sealed in a transparent peel-apart package. Manufactured in Japan.
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 20 units |
| Device type | Medical device |
| Device class | II A |
| CND | A010299 |
| GMDN | 12734 |
Technical features
| Cutting diameter | 4 mm (Ø 4 mm) |
|---|---|
| Sheet length | 7 mm |
| Extraction device | Plunger to facilitate sample removal |
| Blade material | Very sharp stainless steel |
| Handle | Ribbed, firm grip |
| Identification | Size engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual transparent peel-apart packaging |
| Use | Disposable, single-use |
| Application | Dermatology, gynaecology and podiatry |
| Origin | Japan (KAI line) |
| Manufacturer reference | 22636 (SKU Cahnos: GM22636) |
4. Equivalences and Cross-References
This Ø 4 mm punch with plunger belongs to the KAI line, manufactured in Japan by KAI Corporation, and shares the same technical principle as sterile single-use skin biopsy punches on the market. The references indicated are category comparisons verified against official catalogues and regulatory sources (GUDID); as they are different manufacturers, they are not interchangeable 1:1 and must be confirmed with the technical department before use in tenders. There is no equivalence table validated by the manufacturer.
| Manufacturer / Brand | Reference code / SKU | Equivalence level |
|---|---|---|
| KAI Medical (KAI Corporation) | BP-40F | Comparable by category (not interchangeable 1:1) |
| Stiefel (GSK-Stiefel) | SZ1984 / STIEF-BP4 | Comparable by category (not interchangeable 1:1) |
| (Stiefel-type line) | 22586 | Comparable by category (same manufacturer, different line) |
| Integra Miltex (Integra LifeSciences) | 33-34 | Comparable by category (not interchangeable 1:1) |
Within the Cahnos catalogue, the homologous family without plunger, KAI line (Ø 1 to 8 mm), serves as a reference to cover any gauge with the same supplier and quality.
5. Selection tips and variants of interest
The diameter of the punch determines the size of the sample and should be chosen according to the lesion and the intended histopathological study. The 4 mm gauge is the standard range in dermatology for most skin lesions, as it provides a highly representative sample with a contained cosmetic defect. The plunger variant (this reference) is especially recommended when it is desired to facilitate and speed up the extraction of the sample after the circular cut.
The KAI line range covers the full spectrum of diameters with the same quality: 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and 8 mm in standard version (GM22610 to GM22619), plus the plunger variant. This allows the supplier to be standardised and stock of various gauges to be maintained in your dermatology, gynaecology, podiatry or minor ambulatory surgery service. Always check the integrity of the individual package before each use and dispose of the instrument after the procedure in accordance with healthcare waste regulations. For large orders you can request a quote: consult your technical-commercial advisor at Cahnos for conditions and lead times.