We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Disposable 5 mm Sterile Biopsy Punch – Seamless Stainless Steel Single-Use (Box of 10)

Original price was: 16,10 €.Current price is: 9,95 €.

The 5 mm disposable biopsy punch is a sterile single-use device for obtaining accurate and representative skin samples, with a seamless circular stainless steel cutting edge, ribbed ABS handle with pressure-assist platform and size embossed on each unit. Sterilised by gamma radiation, latex-free and phthalate-free, with a 5-year shelf life. Supplied in a box of 10 ready-to-use units. The ideal choice for dermatology, minor outpatient surgery and histopathological diagnosis.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0100772

Description

1. Commercial Introduction

The 5 mm disposable biopsy punch is the reference instrument for obtaining skin tissue samples in the dermatology clinic, minor ambulatory surgery and family medicine units. Sterile and single-use, with a seamless circular stainless steel blade, it allows a cylindrical 5 mm sample to be taken with a clean cut and minimal damage to the surrounding tissue, promoting faster healing and a reliable histopathological report. Its ergonomic design, with a fluted barrel and pressure-assist platform, gives the specialist total control of the manoeuvre in every diagnostic procedure.

2. Technical explanation of the equipment and procedure

Skin biopsy occupies a central place in medical diagnostics: despite the development of complementary techniques, histopathological evaluation of tissue remains the specialist’s reference standard. Given its simplicity of handling and the ability to obtain a sample well defined in length and diameter, the punch is currently the most suitable instrument for taking skin biopsies.

Punch biopsy provides a representative cross-section through the entire cutis, reaching sufficient depth and including a fragment of complete epidermis and dermis for study. The seamless circular cutting edge of stainless steel allows a clean, regular and smooth incision, reducing damage to the surrounding tissue. The fluted ABS barrel with pressure-assist platform ensures controlled and precise sample capture, while the size embossed on each punch prevents identification errors. It is a sterile single-use medical device, free from latex, phthalates and animal or biological products, designed to eliminate reprocessing and the risk of cross-contamination.

3. Technical Specifications

Product type Disposable skin biopsy punch
Diameter 5 mm
Blade material Seamless stainless steel, sharp edge
Handle Ribbed ABS barrel with pressure-assist platform
Identification Size embossed on each punch
Sterility Yes, sterilised by gamma radiation, for individual use
Protection Protective LDPE cap (low-density polyethylene)
Presentation Ready to use, individual blister packaging
Use Disposable, single-use (individual use)
Shelf life 5 years
Application Skin / cutis biopsy: representative cross-section (epidermis and dermis)
Sales format Box of 10 units
Regulatory classification Class IIa medical device, Directive 93/42/EEC (MDD), notified body 2460
Latex / Phthalates / Animal origin Contains no
SKU 0100772

Note: check the integrity of the packaging before use; sterility is not guaranteed if the package is damaged. Store in a cool, dry place (10–40 °C, 35–65 % RH), away from direct sunlight.

4. Equivalences and Cross-References

This 5 mm punch shares the same technical principle as the sterile single-use skin biopsy punches from the main manufacturers on the market: seamless circular stainless steel cutting edge, fluted handle, size embossed on each unit, sterility and individual use. The technical cross-references listed below have been checked against official catalogues and regulatory sources; as they come from different manufacturers, they are not 1:1 interchangeable and must be confirmed with the technical department before use in tenders.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
KAI Medical (KAI Corporation) Biopsy Punch (sterile biopsy punch) BP-50F Comparable by category (not interchangeable 1:1) Blade diameter 5.0 mm; seamless stainless steel cutting edge, fluted handle and embossed size; sterile and disposable, with extended shelf life. Presentation in a dispensing box of 20 units versus a box of 10 units. Verified in the official KAI Europe / KAI Medical catalogue.
Stiefel (GSK-Stiefel) Stiefel Biopsy Punch STIEF-BP5 (alternative SZ1985) Comparable by category (not interchangeable 1:1) Diameter 5 mm; seamless stainless steel cutting edge, fluted handle, size marked on each unit, sterile and disposable, box of 10 units. Same Ø and presentation; handle of equivalent design. Verified with authorised distributors.
GIMA (Italy) GIMA Biopsy Punch (biopsy punch) 22587 (EAN 8023279225877) Comparable by category (not interchangeable 1:1) Diameter 5 mm, seamless stainless steel blade, fluted handle, embossed size, sterile and disposable, box of 10 units. Same Ø and presentation. Class IIa. Verified in the official GIMA catalogue.
Integra Miltex (Integra LifeSciences) Sterile Disposable Biopsy Punch 33-35 Comparable by category (not interchangeable 1:1) Diameter 5.0 mm; seamless stainless steel cutting edge, fluted handle, marked size, sterile with a 5-year shelf life and individual blister. Box of 50 units versus box of 10 units. Verified in GUDID (Identifier 10381780064121, skin-coring punch single-use) and the official Integra LifeSciences datasheet.

There is no equivalence table validated by the manufacturer; the above cross-references are technical comparisons by category checked against official catalogues and regulatory sources, and must be confirmed with the technical department before use in tenders. Within the Cahnos catalogue, this reference belongs to a complete family of disposable biopsy punches from 2 to 8 mm that covers the full range of diameters with the same supplier and quality.

5. Selection tips and variants of interest

The diameter of the punch determines the size of the sample obtained and should be chosen according to the lesion and the planned histopathological study:

  • 2–3 mm: small lesions, aesthetic areas or paediatric patients, minimising scarring.
  • 3–4 mm: standard range in dermatology for most skin lesions.
  • 5–6 mm (this reference): larger amount of tissue or lesions of medium extent; the 5 mm calibre provides a generous sample while keeping the cosmetic defect contained.
  • 8 mm: large lesions, more extensive excisions or studies requiring a bulky sample with complete epidermis and dermis.

Always check that the sample includes complete epidermis and dermis so that the histopathological report is conclusive. For volume requirements, you can order the full range of diameters in the family and keep stock of several calibres in your dermatology, family medicine or minor ambulatory surgery department. Remember to check the individual packaging before each use and dispose of the instrument after the procedure in accordance with healthcare waste regulations.

Additional information

Blade material

Seamless stainless steel

Handle

Ribbed ABS barrel with pressure-assist platform

Identification

Size embossed on each punch

Sterility

Sterile (gamma radiation)

Protection

LDPE protective cap

Presentation

Individual blister pack, ready to use

Use

Disposable, single-use

Shelf life

5 years

Application

Skin / cutis biopsy (representative cross-section: epidermis and dermis)

Sales format

Box of 10 units

Regulatory classification

Class IIa, Directive 93/42/EEC (MDD), notified body 2460

Latex, phthalates, animal origin

Contains no

Diametro mm

5 mm

Reviews

There are no reviews yet.

Be the first to review “Disposable 5 mm Sterile Biopsy Punch – Seamless Stainless Steel Single-Use (Box of 10)”

Your email address will not be published. Required fields are marked *