Description
1. Commercial Introduction
The Ø 4 mm skin biopsy punch, from the KAI line manufactured in Japan, is the instrument of choice for obtaining skin tissue samples in dermatology, gynaecology and podiatry clinics. Its very sharp circular stainless steel cutting edge allows a 4 mm cylindrical sample to be taken with a clean, regular cut and minimal trauma to the surrounding tissue, promoting rapid healing and a reliable histopathological report. Each punch is individually sealed in a peel-apart pack, and the box of 20 units facilitates stock maintenance in diagnostic services.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the skin, including full epidermis and dermis for histopathological examination. The circular stainless steel cutting edge is presented on a 7 mm blade length, reaching sufficient depth for the examination. The fluted plastic handle offers a secure and stable grip even with gloves, while the size is engraved on each punch, preventing identification errors during the procedure. As it is a sterile, disposable, single-use device, it eliminates the sharpening and sterilisation tasks associated with reusable instruments and reduces the risk of cross-contamination in the clinic. The 4 mm diameter constitutes the standard range in dermatology for most skin lesions, providing a highly representative sample with a contained cosmetic defect.
3. Technical Specifications
Disposable skin biopsy punch Ø 4 mm, with a 7 mm blade length, very sharp stainless steel cutting edge and fluted plastic handle. Size engraved on each unit for easy identification. Indicated for dermatology, gynaecology and podiatry. Each punch is individually sealed in a transparent peel-apart pack. Manufactured in Japan.
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 22616 (SKU Cahnos: GM22616) |
| Sales unit | Box of 20 units |
| Device type | Medical device |
| Device class | II A |
| CND | A010299 |
| GMDN | 12734 |
Technical features
| Parameter | Specification |
|---|---|
| Product type | Disposable skin biopsy punch |
| Cutting diameter | 4 mm (Ø 4 mm) |
| Sheet length | 7 mm |
| Blade material | Very sharp stainless steel |
| Handle | Ribbed plastic (firm grip) |
| Identification | Size engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual heat-sealed transparent peel-apart pack |
| Use | Disposable, single-use |
| Clinical areas | Dermatology, gynaecology and podiatry |
| Origin | Made in Japan (KAI line) |
4. Equivalences and Cross-References
This Ø 4 mm punch belongs to the Biopsy Punches line manufactured in Japan (original reference PUNCH PER BIOPSIA KAI), characterised by a very sharp circular stainless steel cutting edge, fluted handle, 7 mm blade length and presentation in a box of 20 units with individual peel-apart pack. The manufacturer does not publish a validated 1:1 equivalence table, so cross-references between manufacturers are technical comparisons by category and must be confirmed with our technical-commercial department before use in tenders.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| KAI Medical | Sterile biopsy punch (Ø 4.0 mm) | BP-40F | Comparable by category (not interchangeable 1:1) |
| Stiefel (GSK-Stiefel) | Stiefel Biopsy Punch Ø 4 mm | STIEF-BP4 / SZ1984 | Comparable by category (not interchangeable 1:1) |
| Catalogue Cahnos | Biopsy Punches Ø 4 mm (box of 10 units, 8 mm blade) | 22586 | Comparable by category (same family, different presentation) |
| Integra Miltex (Integra LifeSciences) | Sterile Disposable Biopsy Punch (Ø 4.0 mm) | 33-34 | Comparable by category (not interchangeable 1:1) |
Within the Cahnos catalogue, reference 0100771 (4 mm disposable punch in a box of 10 units) shares the same cutting Ø with a different presentation. There is no equivalence table validated by the manufacturer; always confirm with your Cahnos technical-commercial advisor before substituting references in tenders or protocols.
5. Selection tips and variants of interest
The punch diameter determines the size of the sample obtained and should be chosen according to the lesion and the planned histopathological examination. The 1 to 3 mm gauges are reserved for small lesions, mucous membranes, aesthetic areas and paediatric patients; 4 to 6 mm constitute the standard range in dermatology for most skin lesions; and the 8 mm gauge is the option for large lesions or studies requiring a bulky sample with full epidermis and dermis. The 4 mm gauge (this reference) provides a highly representative sample while maintaining a contained cosmetic defect.
The KAI line range allows the full range of diameters to be covered with the same quality and supplier (Ø 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and 8 mm; refs. GM22610 to GM22619). If sample extraction needs to be facilitated in this same gauge, a plunger variant (plunger) is available for Ø 4 mm (Ref. GM22636). Always check the integrity of the individual pack before each use: sterility is not guaranteed if the packaging is damaged. Dispose of the instrument after the procedure in accordance with healthcare waste regulations. All products in this catalogue; consult your Cahnos technical-commercial advisor for conditions, lead times and confirmation of equivalences. For large orders you can request a quote.