Description
1. Commercial Introduction
The round shaver burrs (Round Bur) from REGER are high-performance surgical consumables designed for arthroscopic surgery, compatible with the most common shaver connection (hub) systems on the market. The range is offered in diameters of 4.00 mm and 5.50 mm with a length of 130 mm, in standard versions (single-use sterile) and reusable (r), to adapt to the needs and protocols of each surgical centre.
Manufactured by REGER Medizintechnik GmbH (Germany), they are part of the REGER arthroscopy platform together with the Barrel Bur burrs and the PitBull, Wave Cutter and Synovia Cutter blades. They are marketed on a quotation basis with technical-commercial advice from the Cahnos team.
2. Technical Explanation
The shaver burr is the cutting accessory that attaches to the handpiece of the shaver system in minimally invasive arthroscopic surgery. The round geometry (Round Bur) features a spherical burring head that allows debridement and regularisation of bone and cartilage tissue within the joint space, with effective evacuation of fragmented material through the suction system of the handpiece.
The hub coupling must match that of the handpiece to transmit rotation without vibrations or premature wear. The 130 mm length is the standard in arthroscopy and facilitates access to deep joint compartments. The manufacturer offers two presentations: the standard version, sterile and single-use, which maximises cutting freshness and batch traceability, and the reusable version (r), identified by the letter «r» at the end of the reference, designed for high-volume surgical programmes with reduced cost per procedure.
3. Technical Specifications
General characteristics verified against the official catalogue of REGER Medizintechnik GmbH (Arthroscopy system > Shaver blades and burrs):
| Characteristic | Value |
|---|---|
| Brand | REGER |
| Manufacturer | REGER Medizintechnik GmbH (Germany) |
| SKU Cahnos | RGR-FRESA-REDONDA |
| Product type | Round shaver burr (Round Bur) for arthroscopy |
| Length | 130 mm |
| Available diameters | 4.00 mm / 5.50 mm |
| Presentation | Standard (single-use sterile) | Reusable version (r) |
| Sale | Under quotation |
Available references
| REGER reference | Connection (shaver system) | Diameter | Size | Compatible with |
|---|---|---|---|---|
| 829-105-130 | REGER Vimex (Barracuda) | 4.00 mm | Standard | Vimex |
| 829-605-130 | REGER Vimex (Barracuda) | 5.50 mm | Standard | Vimex |
| 829-104-200r | REGER Vimex (Barracuda) | 4.00 mm | Reusable Version (r) | Vimex |
| 829-604-200r | REGER Vimex (Barracuda) | 5.50 mm | Reusable Version (r) | Vimex |
| 823-105-130 | Arthrex | 4.00 mm | Standard | Arthrex |
| 823-605-130 | Arthrex | 5.50 mm | Standard | Arthrex |
| 823-104-200r | Arthrex | 4.00 mm | Reusable Version (r) | Arthrex |
| 823-604-200r | Arthrex | 5.50 mm | Reusable Version (r) | Arthrex |
| 821-105-130 | Smith & Nephew | 4.00 mm | Standard | Smith & Nephew |
| 821-605-130 | Smith & Nephew | 5.50 mm | Standard | Smith & Nephew |
| 821-104-200r | Smith & Nephew | 4.00 mm | Reusable Version (r) | Smith & Nephew |
| 821-604-200r | Smith & Nephew | 5.50 mm | Reusable Version (r) | Smith & Nephew |
| 824-105-130 | J & J, NEXTRA | 4.00 mm | Standard | J&J NEXTRA |
| 824-605-130 | J & J, NEXTRA | 5.50 mm | Standard | J&J NEXTRA |
| 826-105-130 | KARL STORZ | 4.00 mm | Standard | Karl Storz |
| 826-605-130 | KARL STORZ | 5.50 mm | Standard | Karl Storz |
| 822-105-130 | Stryker | 4.00 mm | Standard | Stryker |
| 822-605-130 | Stryker | 5.50 mm | Standard | Stryker |
| 827-105-130 | Conmed Linvatec / Vimex (old) | 4.00 mm | Standard | Conmed Linvatec |
| 827-605-130 | Conmed Linvatec / Vimex (old) | 5.50 mm | Standard | Conmed Linvatec |
| 827-104-200r | Conmed Linvatec / Vimex (old) | 4.00 mm | Reusable Version (r) | Conmed Linvatec |
| 827-604-200r | Conmed Linvatec / Vimex (old) | 5.50 mm | Reusable Version (r) | Conmed Linvatec |
Connection codes (hub) by reference prefix
| Reference prefix | Hub system | Connection code | Compatible with |
|---|---|---|---|
| 829-xxx | REGER Vimex (Barracuda) | DRVI | Vimex |
| 823-xxx | Arthrex | DRAR | Arthrex |
| 821-xxx | Smith & Nephew | DRSN | Smith & Nephew |
| 824-xxx | J & J, NEXTRA | DRNX | J&J NEXTRA |
| 826-xxx | KARL STORZ | DRSZ | Karl Storz |
| 822-xxx | Stryker | DRST | Stryker |
| 827-xxx | Conmed Linvatec / Vimex (old) | DROR | Conmed Linvatec |
4. Equivalences and Cross-References
The Cahnos references with the RGR- prefix (RGR-829-105-130, RGR-823-105-130, etc.) correspond 1:1 with the references in the REGER Medizintechnik GmbH catalogue (same reference without prefix): this is the double coding of the same product. The manufacturer’s coding identifies the connection family: 829 (Vimex/Barracuda), 823 (Arthrex), 821 (Smith & Nephew), 824 (J&J NEXTRA), 826 (KARL STORZ), 822 (Stryker) and 827 (Conmed Linvatec / Vimex old version).
Each burr is installed only on the handpiece of its own shaver system; references from different manufacturers are not interchangeable with each other without the corresponding adapter. No validated 1:1 equivalence tables with third-party manufacturers are available for these specific references; it is recommended to consult with the technical department of Cahnos before any substitution in tenders.
5. Selection tips and variants of interest
- Identify your centre’s system: check the model of the handpiece and shaver motor and select the corresponding reference family (Vimex, Arthrex, Smith & Nephew, J&J NEXTRA, KARL STORZ, Stryker or Conmed Linvatec).
- Burr diameter: choose 4.00 mm for smaller joint spaces and finer burring, and 5.50 mm for greater resection capacity in larger-volume joints.
- Standard or reusable presentation: the standard version (single-use, sterile) maximises cutting freshness and batch traceability; the reusable version (r), identified by the letter «r», reduces the cost per procedure in high-volume programmes with an established reprocessing circuit.
- System accessories: these burrs integrate with the console (800-000-023), the handpiece (800-000-024) and the foot pedal (800-000-025) of the REGER shaver system, as well as with the other blades and burrs of the REGER arthroscopy platform (PitBull, Wave Cutter, Synovia Cutter and Barrel Bur).
- Always verify the reference: confirm the exact reference engraved on the product, including the letter «r» on reusable versions, before formalising the order. All products are supplied on a quotation basis; contact Cahnos for availability and lead times.