We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Barrel shaver burrs (Barrel Bur) REGER for arthroscopy – Ø 4.0 and 5.5 mm x 130 mm, compatible with Vimex, Arthrex, Smith & Nephew, J&J NEXTRA, Karl Storz, Stryker and Conmed Linvatec

Price on request

Barrel shaver burrs (Barrel Bur) from REGER for arthroscopy, compatible with the shaver connection (hub) systems of the main manufacturers: Vimex (Barracuda), Arthrex, Smith & Nephew, J&J NEXTRA, KARL STORZ, Stryker and Conmed Linvatec. Available in 4.00 mm and 5.50 mm diameter with 130 mm length, in standard single-use version and reusable version (r). Ideal for milling and debridement of bone and cartilage tissue in arthroscopic surgery of the knee, shoulder, hip and ankle. Product on quotation with technical-commercial advice from Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-FRESA-BARRIL

Description

1. Commercial Introduction

The barrel shaver burrs (Barrel Bur) from REGER are high-performance surgical consumables designed for arthroscopic surgery, compatible with the most common shaver connection (hub) systems on the market. The range is offered in diameters of 4.00 mm and 5.50 mm with a length of 130 mm, in standard (single-use) and reusable (r) versions, to adapt to the needs and protocols of each surgical centre. Each reference is designed for a specific handpiece system, ensuring an exact fit, no play and reliable cutting performance in the knee, shoulder, hip and ankle. They are marketed on quotation and with the technical-commercial advice of the Cahnos team.

2. Technical Explanation

The shaver burr is the cutting accessory that attaches to the handpiece of the shaver system in minimally invasive arthroscopic surgery. The «barrel» geometry (barrel bur) features a continuous cylindrical cutting surface that allows milling and debridement of bone and cartilage tissue inside the joint space, with effective evacuation of fragmented material through the suction system of the handpiece. The hub coupling must match that of the motor to transmit rotation without vibrations or premature wear. The 130 mm length is the standard in arthroscopy and facilitates access to deep joint compartments. The manufacturer offers two presentations: the standard version, sterile and single-use, which maximises cutting freshness and traceability, and the reusable version (r), identified with the letter «r» at the end of the reference, designed for high-volume surgical programmes with reduced cost per procedure.

3. Technical Specifications

General characteristics according to the official catalogue of REGER Medizintechnik GmbH:

Characteristic Value
Length 130 mm

Available references

REGER reference Connection (shaver system) Diameter Size Compatible with
829-104-130 REGER Vimex (Barracuda) 4.00 mm Standard Vimex
829-604-130 REGER Vimex (Barracuda) 5.50 mm Standard Vimex
829-104-174r REGER Vimex (Barracuda) 4.00 mm Reusable Version (r) Vimex
829-204-130r REGER Vimex (Barracuda) 5.50 mm Reusable Version (r) Vimex
823-104-130 Arthrex 4.00 mm Standard Arthrex
823-604-130 Arthrex 5.50 mm Standard Arthrex
823-104-174r Arthrex 4.00 mm Reusable Version (r) Arthrex
823-204-130r Arthrex 5.50 mm Reusable Version (r) Arthrex
821-104-130 Smith & Nephew 4.00 mm Standard Smith & Nephew
821-604-130 Smith & Nephew 5.50 mm Standard Smith & Nephew
821-105-174r Smith & Nephew 4.00 mm Reusable Version (r) Smith & Nephew
821-204-130r Smith & Nephew 5.50 mm Reusable Version (r) Smith & Nephew
824-104-130 J & J, NEXTRA 4.00 mm Standard J&J NEXTRA
824-604-130 J & J, NEXTRA 5.50 mm Standard J&J NEXTRA
826-104-130 KARL STORZ 4.00 mm Standard Karl Storz
826-604-130 KARL STORZ 5.50 mm Standard Karl Storz
822-104-130 Stryker 4.00 mm Standard Stryker
822-604-130 Stryker 5.50 mm Standard Stryker
827-104-130 Conmed Linvatec / Vimex (old) 4.00 mm Standard Conmed Linvatec
827-604-130 Conmed Linvatec / Vimex (old) 5.50 mm Standard Conmed Linvatec
827-104-174r Conmed Linvatec / Vimex (old) 4.00 mm Reusable Version (r) Conmed Linvatec
827-204-130r Conmed Linvatec / Vimex (old) 5.50 mm Reusable Version (r) Conmed Linvatec

4. Equivalences and Cross-References

The Cahnos references with the RGR- prefix (SKU) correspond 1:1 with the references in the REGER Medizintechnik GmbH catalogue (same reference without prefix). The manufacturer’s coding identifies the connection family: codes starting with 829 correspond to the Vimex (Barracuda) system, 823 to Arthrex, 821 to Smith & Nephew, 824 to J&J NEXTRA, 826 to KARL STORZ, 822 to Stryker and 827 to Conmed Linvatec / Vimex (old version). Each burr is installed only on the handpiece of its own shaver system; references from different manufacturers are not interchangeable with each other without the corresponding adapter. No validated 1:1 equivalence tables with third-party manufacturers are available for these specific references; it is recommended to consult with the technical department of Cahnos before any substitution in tenders.

5. Selection tips and variants of interest

  • Identify your centre’s system: check the handpiece model and shaver motor and select the corresponding reference family (Vimex, Arthrex, Smith & Nephew, J&J NEXTRA, KARL STORZ, Stryker or Conmed Linvatec).
  • Burr diameter: choose 4.00 mm for smaller joint spaces and finer milling, and 5.50 mm for greater resection capacity in larger joints.
  • Standard or reusable presentation: the standard version (single-use, sterile) maximises cutting freshness and batch traceability; the reusable version (r) reduces the cost per procedure in high-volume programmes with an established reprocessing circuit.
  • Always verify the reference: confirm the exact reference engraved on the product, including the letter «r» in reusable versions, before placing the order.

Additional information

Conexión (sistema shaver)

REGER Vimex (Barracuda), Arthrex, Smith & Nephew, J & J, NEXTRA, KARL STORZ, Stryker, Conmed Linvatec / Vimex (old)

Diámetro

4,00 mm, 5,50 mm

Medida

Estándar, Versión Reutilizable (r)

Compatibility

Vimex, Arthrex, Smith & Nephew, J&J NEXTRA, Karl Storz, Stryker, Conmed Linvatec

REGER reference

829-104-130, 829-604-130, 829-104-174r, 829-204-130r, 823-104-130, 823-604-130, 823-104-174r, 823-204-130r, 821-104-130, 821-604-130, 821-105-174r, 821-204-130r, 824-104-130, 824-604-130, 826-104-130, 826-604-130, 822-104-130, 822-604-130, 827-104-130, 827-604-130, 827-104-174r, 827-204-130r

Manufacturer

REGER Medizintechnik GmbH

Product type

Barrel shaver burr (Barrel Bur) for arthroscopy

Geometry

Barrel (Barrel Bur)

Available diameters

4.00 mm and 5.50 mm

Compatible shaver systems

Vimex (Barracuda), Arthrex, Smith & Nephew, J&J NEXTRA, KARL STORZ, Stryker, Conmed Linvatec / Vimex (old)

Available variants

Standard (single-use) and Reusable (r)

Application

Milling and debridement of bone and cartilage tissue in arthroscopic surgery (knee, shoulder, hip, ankle)

Longitud

1.3 cm

Reviews

There are no reviews yet.

Be the first to review “Barrel shaver burrs (Barrel Bur) REGER for arthroscopy – Ø 4.0 and 5.5 mm x 130 mm, compatible with Vimex, Arthrex, Smith & Nephew, J&J NEXTRA, Karl Storz, Stryker and Conmed Linvatec”

Your email address will not be published. Required fields are marked *