We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Fibre optic light cable adapters REGER – Endoscopy tower LYNX-4K/HD (Refs. 897-51 and 897-52)

Price on request

Set of REGER fibre optic light cable adapters, designed for the endoscopy and visualisation tower LYNX-4K/HD. Includes the 897-51 light source side adapter (compatible with W+I/WISAP sources and Storz system) and the 897-52 instrument side adapter (compatible with Storz, Aesculap and Olympus), ensuring a firm coupling, correct optical alignment and efficient loss-free light transmission in every diagnostic and surgical procedure. Essential connection accessories to expand the compatibility of your endoscopy fleet by combining cables and instruments from different manufacturers. Sold on quotation; contact our technical-commercial team at Cahnos for availability and conditions.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-ADAPT-LUZ

Description

Fibre optic light cable adapters REGER

The REGER fibre optic light cable adapters are the connection accessories your LYNX-4K/HD endoscopy and visualisation tower needs to ensure stable, homogeneous and loss-free cold illumination. This set comprises two complementary pieces: the 897-51 adapter, for the light source side, and the 897-52 adapter, for the instrument side. With them, you can integrate light cables and equipment from the main manufacturers on the market (Storz, Aesculap and Olympus) into a single installation, protecting your investment and increasing the versatility of your endoscopy fleet.

Technical explanation

In rigid and flexible endoscopy systems, light is transmitted from the light source to the optic or instrument via fibre optic (F.O.) cables. Each manufacturer uses its own connection geometry on the cable end and on the output port of its light sources, which often prevents combining equipment from different brands.

These REGER adapters overcome this barrier by acting as transition elements: the 897-51 fits on the light source side and the 897-52 on the instrument side. A precise fit prevents light leaks, play and misalignments that would reduce field brightness and worsen image quality, critical aspects in diagnostic and surgical procedures. Installation is simple and requires no modification of the existing cabling.

Technical specifications

Connection adapters for fibre optic light cable from the REGER LYNX-4K/HD family. Each reference is supplied individually in units of 1 piece.

Available references

REGER reference Length / Connection side Compatible with
897-51 Light source side W+I/WISAP Storz
897-52 Instrument side Storz/Aesculap/Olympus

Product data

Field Detail
Brand REGER
Manufacturer REGER Medizintechnik GmbH
SKU Cahnos RGR-ADAPT-LUZ
Manufacturer references 897-51, 897-52
System Endoscopy tower LYNX-4K/HD
Product type Fibre optic light cable adapter
Sales unit 1 pc

Equivalences and cross-references

This product corresponds to the original REGER references 897-51 and 897-52, supplied by Cahnos under SKU RGR-ADAPT-LUZ. No 1:1 equivalents with adapters from other manufacturers are documented in reliable sources; we recommend using the original parts to guarantee mechanical fit and optical transmission.

The fibre optic connection family covers the most common systems on the market. As a functional reference, Cahnos offers light source adapters from other brands with equivalent purpose for Storz/Aesculap/Martin systems (SKU GM30831), WOLF and Henke Sass (GM30832) or Olympus (GM30833), as well as terminal adapters for optics (series GM30840-GM30842). Always verify the compatibility of your connector before any replacement.

Selection tips and variants of interest

Before placing your order, identify the connection end you need to adapt: use reference 897-51 for the light source side (W+I/WISAP connections and Storz system) and reference 897-52 for the instrument or optic side (Storz, Aesculap and Olympus). If your installation combines multiple towers or brands, you may find it practical to have both adapters per unit to configure the lighting set to your needs.

Always keep the coupling surfaces clean and free of dust to preserve optical transmission and avoid loss of brightness. To complete the installation, consider the fibre optic light cable and the light source from the LYNX-4K/HD family. This product is sold on quotation: for orders, complete sets or compatibility queries, contact our technical-commercial department at Cahnos.

Additional information

Longitud

Lado fuente de luz W+I/WISAP, Lado instrumento

REGER reference

897-51, 897-52

Manufacturer

REGER Medizintechnik GmbH

Product type

Fibre optic light cable adapter

Reference 897 51

Light source side adapter W+I/WISAP, compatible with Storz

Reference 897 52

Instrument side adapter, compatible with Storz/Aesculap/Olympus

System

Endoscopy and visualisation tower LYNX-4K/HD

Compatibility

Storz, Aesculap, Olympus, W+I/WISAP

Presentation

Unit sale, on quotation

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Fibre optic light cable adapters REGER – Endoscopy tower LYNX-4K/HD (Refs. 897-51 and 897-52)”

Your email address will not be published. Required fields are marked *