ARTro radiofrequency (RF) generator for arthroscopy with foot pedal | REGER Medizintechnik — Refs. 897-10 and 897-7

Price on request

High-end ARTro radiofrequency generator from REGER Medizintechnik GmbH, the energy unit of the REGER arthroscopic plasma system, developed specifically for arthroscopic surgery. The unit incorporates the manufacturer’s latest technology and software and is supplied with its foot pedal (ref. 897-7). It includes the ARTro unit (ref. 897-10), compatible with the handles, BiVac bipolar cables and vaporisation electrodes of the REGER ecosystem. Product sold on quotation: consult our technical-commercial team for availability and conditions.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-ARTRO-GEN

Description

1. Introduction

The ARTro radiofrequency generator from REGER Medizintechnik GmbH is the high-end energy unit of the REGER arthroscopic plasma system. Developed specifically for arthroscopy, it incorporates the latest technology and software from the German manufacturer to ensure precise and safe electrosurgical treatment of intra-articular soft tissue. This product includes the ARTro unit (ref. 897-10) together with its foot pedal (ref. 897-7), forming the complete configuration for working with the handles, BiVac bipolar cables and electrodes of the system. A reliable, high-performance solution for hospitals, clinics and arthroscopic surgery centres.

2. Technical explanation of the equipment

The ARTro generator concentrates radiofrequency energy at the tip of the active electrode to vaporise, ablate and coagulate soft tissue within the joint space in arthroscopic procedures of the knee, shoulder, elbow and ankle. The unit works with an arthroscopic plasma system and allows precise control of the energy applied to the tissue, with a controlled thermal effect on adjacent structures. The foot pedal (ref. 897-7) allows hands-free activation of the generator during the procedure, leaving both of the surgeon’s hands free to handle the arthroscopic instruments.

3. Technical specifications and references

ARTro system specifications

Characteristic Value
Brand REGER
Manufacturer REGER Medizintechnik GmbH
Set type High-end high-frequency (HF) / radiofrequency (RF) generator
Indication Arthroscopy (developed specifically for this specialty)
Working frequency 333 kHz
Operating modes Bipolar and monopolar
Actuation Foot pedal (footswitch) and hand switch
Technology and software Latest technology and software from the manufacturer
Supply ARTro unit (897-10) and foot pedal (897-7)

Version data with technical detail (variant 897-10V)

Characteristic Value
Voltage 110V
Output power Bipolar cut: 250 W; bipolar coagulation: 200 W; monopolar cut: 200 W; monopolar coagulation: 180 W
Rated input power 1350 VA
Frequency 50/60 Hz
Equipment protection 2 x T 8A/250V
Protection against excessive heating factor Automatic current control so that the heating factor does not exceed 30 A²s
NEM system (neutral electrode monitoring) Neutral electrode monitoring
Protection / safety / risk class I / CF / IIb
IP code IP 2X according to EN 60529
Low/high frequency leakage currents IEC 60601-2-2 / IEC 60601-1-1
Power selection Levels 1-9
Scope of delivery Mains cable and user manual

Available references

REGER reference Type Compatible with
897-7 Foot switch ARTro
897-10 ARTro unit

4. Equivalences and Cross-References

This set is identified in the REGER Medizintechnik catalogue by the references RGR-ARTRO-GEN (SKU Cahnos), RGR-897-10 / 897-10 (ARTro unit) and RGR-897-7 / 897-7 (foot pedal). Reference 897-10V corresponds to the version of the ARTro radiofrequency generator with a published detailed technical data sheet (supplier path: LYNX-4K/HD Tower > RF-Plasma System > RF-Generator). The ecosystem is completed by the BiVac bipolar handles and cables (series 92888/92889), the single-use BiVac vaporisation electrodes (series 890/891), the BiCart bipolar electrodes and the monopolar arthroscopy electrodes from series 800/802/805. No direct 1:1 equivalence tables with generators from other brands have been identified in reliable sources; to validate the replacement or integration of platforms, please consult our technical department.

5. Selection tips and variants of interest

This ARTro generator with foot pedal is the ideal option if you have or plan to install a REGER arthroscopic plasma system (BiVac/ARTro) and want the complete configuration of energy unit and activation. The foot pedal (ref. 897-7) is the recommended complement for hands-free activation during the procedure. Complete your configuration with the BiVac bipolar handles and cables (references 92889-6, 92889-14, 92888-6 and 92888-16), the single-use vaporisation electrodes and the BiCart bipolar electrodes of the system. Always check the supply voltage of your installation before commissioning. Product without published price: request your personalised quote from the technical-commercial team at Cahnos.

Additional information

Tipo

Pedal, Unidad ARTro

REGER reference

897-7, 897-10

Manufacturer

REGER Medizintechnik GmbH

Indications

Arthroscopy

Working frequency

333 kHz

Operating modes

Bipolar and monopolar

Actuation

Foot pedal and hand switch

Output power

Bipolar cut 250 W; bipolar coagulation 200 W; monopolar cut 200 W; monopolar coagulation 180 W

Voltage

110V (variant 897-10V)

Protection class

I

Safety class

CF

Risk class

IIb

IP code

IP 2X according to EN 60529

Scope of delivery

ARTro unit (897-10), foot pedal (897-7), mains cable and user manual

Compatibility

Arthroscopic plasma system REGER (BiVac/ARTro)

Reviews