Description
1. Introduction
The Endotracheal Tube ENDOSID Magill uncuffed 3 mm with Murphy eye (Ref. 843030) is a single-use medical device designed for safe airway management in neonates, infants and patients with very small airway diameters. Its design combines the classic Magill curve with the additional safety of the Murphy eye, offering the professional a precise, reliable and easy-to-use solution in critical settings such as the neonatal intensive care unit (NICU), the paediatric operating theatre and emergency departments.
2. Technical Explanation
The endotracheal tube is inserted into the trachea to secure a patent airway and allow mechanical ventilation or administration of anaesthesia. The Magill configuration, with its characteristic curve, facilitates insertion in small patients and atraumatic positioning. As it lacks an inflatable cuff, sealing is achieved by the natural fit of the tube diameter against the tracheal mucosa, minimising the risk of pressure injury in immature airways. The Murphy eye, a lateral opening located near the distal tip, acts as an alternative ventilation pathway: if the main lumen of the tube becomes obstructed by secretions or kinking, airflow continues through this orifice, ensuring continuity of ventilation.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | 843030 |
| Inner diameter | 3 mm |
| Type | Magill, without cuff |
| Murphy eye | Yes |
| Material | Medical grade (transparent PVC), flexible and durable |
| Connector | 15 mm standard (ISO 5356-1) |
| Radiopacity | Radiopaque contrast line for imaging guidance |
| Latex | Free of natural rubber latex |
| Function | Continuous ventilation with alternative pathway in case of obstruction |
| Clinical application | Neonatal intubation and extremely narrow airways |
| Use environments | NICU, paediatric operating theatres and emergency departments |
| Presentation | Box of 10 units |
| Use | Disposable, single-use |
The ENDOSID family with Murphy eye and uncuffed covers a complete range of sizes for neonatal and paediatric intubation:
| Gauge | Reference |
|---|---|
| 2 mm | 843020 |
| 2.5 mm | 843025 |
| 3 mm | 843030 |
| 3.5 mm | 843035 |
| 4 mm | 843040 |
| 4.5 mm | 843045 |
| 5 mm | 843050 |
| 5.5 mm | 843055 |
| 6 mm | 843060 |
4. Equivalences and Cross-References
This tube is part of the ENDOSID airway management family from Cahnos, with Magill design, uncuffed and with Murphy eye. As complementary references of the same 3 mm size: the tube without Murphy eye corresponds to Ref. 842030, the cuffed version with Murphy eye to Ref. 841030 and the standard Magill tube to Ref. 840030. The 15 mm connector complies with ISO 5356-1, so the device is compatible with standard circuits and ventilators on the market. For rapid intubation settings, the family also includes emergency kits (for example, Ref. 845055 and 845060 in other sizes) that integrate this type of tube with essential accessories. It is recommended to always verify the size and configuration (cuffed or uncuffed and with or without Murphy eye) before substituting one reference for another.
5. Selection tips and variants of interest
The selection of size should be based on the patient’s age and weight: for neonates and premature infants, sizes from 2 to 3.5 mm are used; for infants and young children, sizes from 3.5 to 5 mm. The Murphy eye is especially recommended when there is a risk of obstruction of the distal lumen by secretions or kinking. In long-duration procedures or when an airtight seal of the airway is required, consider the cuffed version of the same family (Ref. 841030 for 3 mm). To complete your equipment, ENDOSID also offers intubation stylets and emergency kits in all sizes. Consult our technical-commercial team for approval of references and large volume orders.