Description
1. Commercial Introduction
Stimuplex® D is the reference needle from B. Braun for anaesthetic location and blockade using single-puncture techniques applied to plexus and peripheral nerve anaesthesia. Designed to work with nerve stimulation and, complementarily, with ultrasound guidance, it gives the anaesthetist total control over the tip position throughout the procedure: maximum current concentration at the distal electrode, complete shaft insulation and depth markings that provide direct visual feedback. A consolidated clinical solution for regional anaesthesia services seeking precision, safety and repeatability in every block.
2. Technical explanation of the equipment and procedure
The Stimuplex® D needle is completely insulated except at the tip: it incorporates a pin-point electrode at the distal end that concentrates all the stimulus current in a very small point, so that the minimum distance between needle and nerve is detected with a very low threshold current (usually in the range of 0.2–0.5 mA). This configuration reduces the risk of direct nerve puncture and improves block precision.
During the procedure, the needle is connected to the nerve stimulator via its hub and locking connector; once the optimal motor response is located, the local anaesthetic is administered through the 500 mm extension line without disconnecting the assembly. The shaft has depth graduations every 1 cm, and the ergonomic translucent green hub incorporates the bevel orientation indicator. It is available in two bevel geometries —15° and 30°— to suit personal puncture preferences and the tissue sliding characteristics; the 30° bevel allows, if required, a small preliminary skin incision to facilitate passage through the skin.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Product type | Needle for anaesthetic location and blockade (single puncture / single shot) |
| Indication | Plexus anaesthesia and peripheral nerve block with nerve stimulation and ultrasound imaging |
| Insulation | Complete except for the bevel; tip electrode (pin-point type) that concentrates the stimulus current |
| Available bevels | 15° and 30° (faceted), depending on puncture and sliding preference |
| Gauge | 22 G (0.70 mm outer cannula diameter) |
| Verified lengths | 50 mm (22 G × 2″) and 120 mm (22 G) in the references reviewed |
| Depth graduation | Markings every 1 cm on the shaft |
| Echogenicity | Yes: compatible with ultrasound guidance (visibility depends on the reference and the equipment configuration) |
| Hub | Ergonomic, translucent green, with bevel orientation indicator |
| Connection | Luer-Lock (locking connector on the needle hub) |
| Extension line | 500 mm injection tube (outer ø 2.25 mm / inner ø 1.15 mm) |
| Compatibility | B. Braun nerve stimulators from the Stimuplex series (HNS11 / HNS12); for optimal connection and safety, it is recommended to combine products from the same brand |
| Material | Stainless steel needle; components free from latex and DEHP |
| Sterilisation | Ethylene oxide (EO), individual sterile packaging |
| Use | Single-use, non-reusable |
| Presentation | Box of 25 units |
References verified in the official B. Braun catalogue and distribution channel:
| Reference | Description | Bevel | Size | Presentation | Source |
|---|---|---|---|---|---|
| 4892105 | Stimuplex® D SH, stimulation needle with extension line | 15º | 22 G × 2″ (0.70 × 50 mm) | Individual packaging (box of 25) | Official B. Braun catalogue |
| 4894162N | Stimuplex® D, stimulation needle (channel variant) | 15º | 0.70 × 120 mm (22 G) | Individual packaging (box of 25) | Distribution channel — pending direct confirmation with manufacturer |
4. Equivalences and Cross-References
The references 4892105 and 4894162N belong to the Stimuplex® D line itself and fulfil the same clinical function (stimulation needle for single puncture), differing in gauge and length; neither replaces the other without first checking the size required for the block. Within the same brand, the Stimuplex® family is completed by the Stimuplex® A (short 30° bevel), Stimuplex® Ultra 360® (360° echogenic pattern) and Contiplex® (continuous block with catheter) lines, all comparable by category but not interchangeable 1:1: they differ in echogenicity, tip geometry and functionality (single puncture versus catheterisation).
As alternatives from other brands, in this category of needles for neurostimulation- and ultrasound-guided block, manufacturers such as Pajunk (UniPlex®/SonoPlex® lines) and Vygon (needles for ultrasound- and stimulation-guided peripheral block) operate. These options are comparable at category level and never interchangeable 1:1 with Stimuplex® D: before any substitution, the gauge and length, bevel angle, material and composition (latex/DEHP), connection (Luer-Lock or NRFit® standard), echogenicity and compatibility with the service’s nerve stimulator must be verified one by one.
There is no equivalence table validated by the manufacturer for cross-referencing with other brands; consult the technical department before use in tendering.
5. Selection tips and variants of interest
- Choose the bevel according to your technique: the 15° bevel offers finer sliding through tissues and is preferred in superficial approach blocks; the 30° bevel provides greater tactile sensitivity and control, and allows a small preliminary skin incision if required.
- Confirm the length according to the depth of the block: for superficial approaches, short lengths are used (e.g. 50 mm, reference 4892105), while deep blocks require longer needles (e.g. 120 mm, reference 4894162N). Always verify the exact size before ordering.
- Verify the connection: this line is available with a Luer-Lock connection; if your department works with NRFit® systems, consult the NRFit® variants of the Stimuplex family to avoid connection incompatibilities.
- Combine it with the appropriate neurostimulator: for optimal connection and maximum safety, use it with B. Braun neurostimulators from the Stimuplex series (HNS11 / HNS12).
- Plan the order by boxes: the product is marketed in boxes of 25 units with individual sterile packaging; assess the department’s monthly consumption to optimise stock.
- For intensive ultrasound-guided use, consider the Stimuplex® Ultra 360® line from the same manufacturer, with a 360° echogenic pattern and hyperechoic tip codes.







Reviews