Description
1. Introduction
The Perifix® Paediatric NRFit® Trays from B. Braun are complete sterile systems designed to perform continuous epidural anaesthesia in paediatric patients with maximum safety and comfort. Each tray brings together the essential components (needle, catheter, connector, filter and syringes) manufactured in specific sizes for newborns, infants and school-age children, which simplifies preparation of the workstation, reduces times and minimises the risk of errors during the procedure.
All elements incorporate the NRFit® safety connection, in accordance with standard ISO 80369-6, a small-diameter connector specific to neuraxial applications that is mechanically incompatible with Luer connectors of other routes (intravenous, enteral or respiratory), drastically reducing the risk of incorrect connections in anaesthesiology services, paediatric surgery and pain units.
2. Technical explanation of the procedure
In paediatric epidural anaesthesia, the puncture is performed with a Perican® epidural needle with Tuohy bevel, whose design allows the epidural space to be located using the loss of resistance technique, assisted by the Perifix® LOR syringe included in the tray. Through the needle, the Perifix® ONE 20 G epidural catheter is introduced, 1000 mm in length, manufactured with a polyamide core (rigidity necessary for easy insertion) and an outer polyurethane cover (softness for placement inside the body), with 6 lateral micro-holes that favour uniform distribution of the local anaesthetic and a radiopaque marker for imaging control.
The system is completed with a crocodile-type catheter connector, tunnelled and threadless, with an ergonomic and flat profile, and a flat Perifix® 0.2 µm filter that retains particles and microorganisms, placed between the infusion line and the catheter connector. The filter is fixed to the patient’s skin using the Perifix® PinPad, a hypoallergenic adhesive base that allows secure anchoring and free rotation of the filter. The NRFit® connection (ISO 80369-6) guarantees mechanical incompatibility with non-neuraxial routes, preventing administration via the wrong route.
3. Technical specifications and tables
Available references (sold in boxes of 10 units)
| Reference | Model | Epidural needle | Bevel / Graduation | Needle length | Catheter | Catheter length | Catheter diameter (ext./int.) | Catheter material | Holes | Filter | Max. pressure | Syringe included | PinPad |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 45120061N-01 | PERIFIX ONE PAED 18 NRFIT | 18 G | Tuohy, graduated every 0.5 cm | 50.00 mm | ONE 20 G | 1000 mm | 0.85 / 0.45 mm | PA, PUR | 6 lateral | 0.2 µm (0.70 ml) | 7.0 bar | 1 x Omnifix 3 ml NRFit Lock | Yes |
| 45120141N-01 | PERIFIX ONE PAED 20 NRFIT | 20 G | Tuohy, graduated every 0.5 cm | 50.00 mm | ONE 20 G | 1000 mm | 0.85 / 0.45 mm | PA, PUR | 6 lateral | 0.2 µm (0.70 ml) | 7.0 bar | 1 x Omnifix 3 ml NRFit Lock | Yes |
Tray composition
- Perican® epidural needle: Tuohy bevel, markings every 0.5 cm, transparent hub with integrated wings and coloured stylet; gauge 18 G or 20 G depending on reference (length 50 mm), NRFit® connection.
- Perifix® ONE epidural catheter: polyamide and polyurethane; 3 pairs of lateral micro-holes; markings between 20 mm and 200 mm; introducer guide; gauge 20 G and length 1000 mm in both references.
- Perifix® catheter connector: crocodile type, tunnelled and threadless; ergonomic and flat; NRFit® connection.
- Flat Perifix® 0.2 µm filter: small, rounded and ergonomic; filling capacity 0.45 ml; resistance up to 7 bar; NRFit® connection.
- Perifix® PinPad: exclusive fixation system for the flat Perifix® 0.2 µm filter with hypoallergenic adhesive.
- Perifix® LOR syringe: 3-body syringe with excellent sensitivity; NRFit® connection.
- Omnifix® 3 ml syringe: 3-body, with NRFit® connection.
General characteristics
| Property | Value |
|---|---|
| Brand / Manufacturer | B. Braun (B. Braun Melsungen AG) |
| Family | Perifix® (regional anaesthesia) |
| Product type | Tray for continuous epidural anaesthesia |
| Application | Epidural — paediatric population |
| Connection | NRFit® (ISO 80369-6) |
| Packaging | Blister |
| Contains PVC | No |
| Contains latex | No |
| Contains DEHP | No |
| Use | Single-use |
| Sterility | Sterile |
| Sterilisation | EO (ethylene oxide) |
| Presentation | Box of 10 units |
4. Equivalences and Cross-References
The Perifix® Paediatric NRFit® Trays belong to the closed Perifix® regional anaesthesia system from B. Braun with NRFit® safety connection. Within the same manufacturer, the family is completed with the Perifix® ONE NRFit® catheter, the Perifix® LOR NRFit® syringe (refs. 4638110 and 4637110), the Perifix® PinPad (ref. 4515510) and the Perifix® NRFit® Trays for adults, as well as the Perifix® Equipment and the Perifix® Mini Sets NRFit® for lower-volume protocols. All these references share the neuraxial connection standard ISO 80369-6.
There is no 1:1 equivalence table validated by the manufacturer that allows these trays to be replaced by sets from other manufacturers. On the market, the homologous families of paediatric epidural anaesthesia trays from Pajunk®, Vygon and ICU Medical/Portex® should be considered comparable at category level, not interchangeable reference by reference, and it is mandatory to verify in each brand’s technical data sheet the paediatric size, needle and catheter gauge, material, type of connection and authorised target population before any substitution in tenders.
5. Selection tips and variants of interest
Select the reference according to the age and characteristics of the paediatric patient: the REF 45120061N-01 (PERIFIX ONE PAED 18 NRFIT) incorporates an 18 G epidural needle and the REF 45120141N-01 (PERIFIX ONE PAED 20 NRFIT) a 20 G needle; both include a 1000 mm Perifix® ONE 20 G catheter with NRFit® connection. Assess the gauge according to the department protocol and the patient’s body habitus, and complete the system with other NRFit® components from the Perifix® range to maintain a closed neuraxial circuit incompatible with other routes.
These trays are supplied in boxes of 10 units and are sold on quotation. To ensure sterility, check the integrity of the blister before use; each tray is single-use and must not be re-sterilised. Consult the technical-commercial team at Cahnos for advice on sizes, quantities and supply conditions for the paediatric Perifix® range.







Reviews