Description
1. Introduction
The 3.5 mm oronasal cuff endotracheal tube (Ref. ETAN35C02 / BRLETAN35C02) is a single-use airway management device designed for oral or nasal intubation of paediatric patients. Made of thermo-sensitive polyvinyl chloride (PVC), it adapts gently to body temperature, combining the stability required for guided placement with the appropriate flexibility for comfortable use during ventilation. It is the perfect ally for operating theatres, paediatric intensive care units, accident and emergency, emergency care and resuscitation, where the airtight cuff seal ensures safe and effective positive-pressure ventilation.
2. Technical explanation of the equipment and procedure
In tracheal intubation, the tube is inserted orally or nasally under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. This model incorporates a low-pressure, high-volume cuff, inflated via the blue indicator balloon with Luer connection and one-way valve, which creates an atraumatic seal against the tracheal wall: it allows positive-pressure ventilation without significant leaks and prevents aspiration of secretions. The Murphy eye, a distal lateral orifice, acts as an alternative ventilation route if the main lumen becomes obstructed; the pre-curved, atraumatic Magill tip (conforming to applicable ISO/EN standards) facilitates injury-free advancement, and the radiopaque line, together with the depth graduation, allows radiographic verification of position relative to the vocal cords. It is a single-use product: it must be disposed of after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the data published in the manufacturer’s catalogue for this reference:
| Parameter | Specification |
|---|---|
| Type | Endotracheal tube with cuff, oral/nasal (oronasal) use, Magill-type curve |
| Inner diameter | 3.5 mm |
| Material | Thermosensitive polyvinyl chloride (PVC) |
| Sleeve | Low pressure, high volume, atraumatic |
| Indicator balloon | Blue, with Luer connection and one-way valve |
| Murphy eye | Yes, atraumatic rounded edge |
| Tip | Atraumatic pre-curved Magill, conforming to applicable ISO/EN standards |
| Connector | 15M |
| Marking | Graduated with depth markings (verification relative to the vocal cords) and radiopaque line for clear identification under X-ray |
| Use | Single-use, disposable |
| Indications | Positive-pressure ventilation; anaesthesia induction if a face mask cannot be used; suction and protection of tracheal and bronchial secretions |
Available references
This size is part of the range of oral/nasal endotracheal tubes with cuff and Murphy eye available in the catalogue (nomenclature ETAN…C02):
| Reference | Inner diameter |
|---|---|
| ETAN35C02 / BRLETAN35C02 | 3.5 mm (this product) |
Contact the technical-commercial team at Cahnos for the other sizes available in the family.
4. Equivalences and Cross-References
The manufacturer’s reference ETAN35C02 matches the range’s own code BRLETAN35C02 (distributor SKU Cahnos); both correspond to the same 3.5 mm oronasal cuff endotracheal tube. There is no equivalence table validated by the manufacturer that cross-references this reference with products from other brands; oral endotracheal tubes with cuff on the market belong to the same functional category and general clinical indication, but they are not interchangeable 1:1. Before any substitution, the internal diameter, material type, presence of Murphy eye, cuff type and applicable standards must be verified item by item.
5. Selection tips and variants of interest
The 3.5 mm size is intended for paediatric patients (young children); as a general clinical practice guideline, in paediatrics the largest size compatible with the patient’s anatomy and age is selected, always according to airway assessment and the centre’s protocol. After intubation, inflate the cuff via the pilot balloon and maintain a sealing pressure within the usual clinical range to minimise damage to the tracheal mucosa (check the service protocol). The catalogue offers adjacent sizes from the same range to complete the paediatric intubation trolley. Single-use product: do not re-sterilise or reuse. Contact the technical-commercial department at Cahnos for samples, volume conditions and reference approval for your tender.