Description
1. GREEN F.O. laryngoscope blade for extra-large adult
The laryngoscope blade (blade) “GREEN” fibre optic type McIntosh No. 5 is the reference solution for direct laryngoscopy and orotracheal intubation in adult patients of large build or extra-large physique within the GREEN laryngoscope series. Its fibre optic illumination system with detachable light guide guarantees maximum light transmission, with a bright and stable beam that allows clear visualisation of the glottis even in difficult access conditions.
Made of corrosion-resistant, non-magnetic austenitic stainless steel, it combines robustness, durability and safety in reprocessing. It is the professional choice for anaesthesiology, emergency, critical care and operating theatre departments seeking reusable, reliable instruments compatible with the most widely used Green standard handles on the European market.
2. Technical explanation of the equipment and procedure
Direct laryngoscopy with a McIntosh-type blade is the classic and most widely used technique for endotracheal intubation. The curved profile of the blade displaces the base of the tongue and guides the epiglottis, aligning the visual axis from the oral cavity to the glottic opening without the need to directly lift the epiglottis. Size No. 5 is specifically designed for large adult anatomies, where an insufficient blade would compromise visualisation.
This blade incorporates a high-quality fibre optic (F.O.) bundle with a detachable light guide: light is conducted from the handle to the distal end of the blade, concentrating illumination at the exact point of visualisation and avoiding the loss of brightness typical of conventional systems. The matte finish reduces reflections on tissues and improves contrast, while the non-magnetic material and compatibility with moist heat and plasma sterilisation allow safe reprocessing in the sterilisation centre.
3. Technical Specifications
Reusable fibre optic laryngoscope blade from the “GREEN” FIBRE OPTIC BLADES line, belonging to the GREEN LARYNGOSCOPES series.
| Characteristic | Specification |
|---|---|
| Manufacturer reference (SKU) | 34474 |
| Blade model | McIntosh (Mc INTOSH) No. 5 |
| Population | Extra-large adult (Adult x-large) |
| Blade type | Fibre optic (F.O.) with detachable light guide, matt anti-reflective surface |
| Material | Austenitic stainless steel (corrosion-resistant, non-magnetic) |
| Compatibility | Green standard handles to BS EN ISO 7376 |
| Sterilisation | Autoclavable up to 134 °C for 5 minutes (up to 2,000 cycles); compatible with plasma sterilisation |
| Compatible power sources | AA and C batteries, or 2.5 V and 3.5 V rechargeable batteries; handles with xenon/halogen or LED bulbs |
| Warranty | 3 years |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 34474 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | Z12021003 |
| GMDN | 46827 |
| EAN | 8023279344745 |
Advantages certified by the manufacturer:
- Maximum light transmission thanks to durable, high-quality fibres.
- Blades specifically designed to facilitate intubation.
- Matt finish to reduce reflections.
- Autoclavable up to 134 °C for 5 minutes; up to 2,000 autoclave cycles.
- Compatible with plasma sterilisation.
- Compatible with Green standard handles according to BS EN ISO 7376.
- Made from austenitic stainless steel, rust-proof.
- Long-lasting: offers a 3-year warranty.
- All blades are non-magnetic.
4. Equivalences and Cross-References
This blade belongs to the international Green System standard (BS EN ISO 7376), so it is interchangeable at connection level with reusable laryngoscope handles that meet this same standard, regardless of their battery combination or light source (AA or C batteries, 2.5 V and 3.5 V rechargeable batteries, xenon/halogen bulbs or LED).
Within the catalogue itself, the series of fibre optic blades with homologous McIntosh sizes includes the references of the MAXLITE line (sizes No. 0 to No. 5, refs. 58056 to 58061), with which it shares geometry, sizing and profile; however, these are lines from the same manufacturer and their replacement must be confirmed with the technical department according to the equipment configuration. There is no 1:1 equivalence table validated by the manufacturer against third-party codes (e.g. Heine, Penlon, Riester or KaWe); before replacing a blade from another brand, the fit of the connection, profile and size must be verified according to BS EN ISO 7376 and the reference must be checked with the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
The blade size must be chosen according to the patient’s age and anatomy: size No. 5 (this reference) is indicated for adults of large build or extra-large physique; for standard adults, size No. 3 is recommended and for large adults size No. 4, while the lower sizes of the same series cover paediatric patients, infants and newborns.
To complete the laryngoscope, combine this blade with a standard Green handle (BS EN ISO 7376) from the GREEN range: the 2.5 V handles accept standard or rechargeable batteries, and the series offers xenon/halogen or LED light sources in 2.5 V and 3.5 V versions, with AA or C batteries. Always verify the fit compatibility before each procedure and follow the recommended sterilisation protocol (autoclave at a maximum of 134 °C for 5 minutes, with a limit of 2,000 cycles) to extend the instrument’s service life and maintain the warranty. For complete fittings, airway trolley configurations or tenders, contact the technical-commercial department of Cahnos:. For large orders you can request a quote.




Reviews
There are no reviews yet.