We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Emergency laryngoscope case – Plastic handle + 6 disposable blades (Miller 0, 1, 2 and MacIntosh 2, 3, 4) – Ref. 34384

43,70 €

Emergency laryngoscopy case (ref. 34384) with plastic handle and 6 disposable blades covering from paediatric to adult patients: Miller 0, 1 and 2, and MacIntosh 2, 3 and 4. The single-use blades eliminate sterilisation times and prevent cross-contamination, keeping the kit always ready for intubation in emergency departments, operating theatre, ICU, ambulances and airway trolleys. Class II A medical device, sales unit: 1 case. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM34384

Description

1. Commercial Introduction

The emergency laryngoscopy case (ref. 34384) is the complete, ready-to-use solution that guarantees orotracheal intubation in critical situations: cardiorespiratory arrests, hospital emergencies, out-of-hospital emergencies, operating theatre and airway trolleys. It includes a plastic handle and six disposable blades covering from paediatric to adult patients in a single set.

As the blades are single-use, the set eliminates sterilisation times and the risk of cross-contamination between patients, a decisive advantage in high-turnover departments. An autonomous, hygienic and always operational kit backed by a leading manufacturer of anaesthesia equipment.

2. Technical explanation of the equipment and procedure

Direct laryngoscopy is the standard technique for endotracheal intubation: the blade displaces the soft tissues and allows visualisation of the glottis to guide the tube into the trachea. This case combines the two classic blade profiles: the straight Miller 0, 1 and 2, which lift the epiglottis directly and are indicated for paediatric patients and small-calibre anatomies, and the curved MacIntosh 2, 3 and 4, which displace the base of the tongue to expose the larynx in larger patients.

The six blades are disposable (single-use) and attach to the included plastic handle, which acts as a support and light source. By discarding each blade after the procedure, reprocessing of the instrument is avoided and cross-infection is prevented, keeping the equipment ready for the next use. The set is presented in a practical emergency case designed for transport and immediate storage.

3. Technical Specifications

Emergency laryngoscopy case, consisting of a plastic handle and six disposable blades with straight (Miller) and curved (MacIntosh) profiles.

Contents 1 plastic handle + 6 disposable blades
Blade profile Miller (straight) and MacIntosh (curved)
Blade sizes Miller 0, 1, 2 and MacIntosh 2, 3, 4
Blade type Disposable (single-use)
Indicated population Paediatric, adult and large adult
Presentation Emergency case (emergency case)

Product data

Manufacturer GIMA
Manufacturer reference 34384 (SKU Cahnos GM34384)
Sales unit 1 pc
Device type Medical device
Device class II A
CND Z12021003
EAN 8023279343847

4. Equivalences and Cross-References

Within the catalogue, this case is complemented by the single-use fibre optic (F.O.) disposable blades of the 57996-58000 series (Green ISO 7376 system), which require a fibre optic handle to operate, and by the reusable GREEN fibre optic sets (refs. GM34451, GM34452, GM34453, GM34454 and GM34455).

No 1:1 equivalence table validated by the manufacturer is available for cases from other brands (such as Heine, Riester, KaWe or PROACT). The PROACT disposable blades (refs. MRHPCMIL00 to MRHPCMIL3 and MRHPCMAC1 to MRHPCMAC4) share the single-use category and Green ISO 7376 connection system, but differ in handle, material and presentation, so they are not directly interchangeable. Before any substitution in specifications or tenders, verify compatibility with the technical-commercial department of Cahnos.

5. Selection tips and variants of interest

Choose the blade size according to the patient: Miller 0 and 1 for neonates and infants, Miller 2 and MacIntosh 2 for larger children, and MacIntosh 3 and 4 for adults. As the blades are disposable, a new blade must be used for each patient to maintain maximum hygiene; replenish consumption with spare parts of the same reference or complete the set with the disposable blades of the F.O. series. The manufacturer does have a fibre optic handle available.

For large orders you can request a quote: ask our technical-commercial team for terms and availability.

Additional information

Manufacturer reference

34384

Product type

Emergency laryngoscopy case

Contents

1 plastic handle + 6 disposable blades

Blade profile

Miller (straight) and MacIntosh (curved)

Blade sizes

Miller 0, 1, 2 and MacIntosh 2, 3, 4

Blade type

Disposable (single-use)

Handle material

Plastic

Indicated population

Paediatric, adult and large adult

CND code

Z12021003

EAN

8023279343847

Presentation

Emergency case (emergency case)

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF · Label Prodotto PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Emergency laryngoscope case – Plastic handle + 6 disposable blades (Miller 0, 1, 2 and MacIntosh 2, 3, 4) – Ref. 34384”

Your email address will not be published. Required fields are marked *