Description
1. Introduction
The Guedel airway ISO6 6 cm (ref. 830003M) is a medical device designed to keep the oropharyngeal airway open in unconscious patients, with depressed level of consciousness or under general anaesthesia. It is a fundamental element in the intubation trolley of operating theatres, emergency departments, critical care units and patient transport, where speed and reliability are decisive. Its anatomical design, medical-grade material and practical unit presentation make it the ideal solution for professionals requiring reliable airway equipment that is quick to place and of contained cost.
2. Technical explanation of the device
The Guedel oropharyngeal airway acts by preventing the tongue and soft tissues from collapsing against the posterior pharyngeal wall, keeping the airway patent during ventilation with a self-inflating bag, anaesthetic induction or cardiopulmonary resuscitation. It is made of rigid medical plastic with an anatomical curve that reproduces the morphology of the palate and pharynx; its central channel and lateral reinforcements ensure a continuous and stable airflow, as well as facilitating suction of secretions. It is a single-use, disposable product that prevents cross-contamination between patients. The ISO6 size, with a length of 6 cm, constitutes an intermediate step in the range and is indicated for older children, adolescents of small build and reduced oropharyngeal anatomies.
3. Technical Specifications
The main features of the Guedel airway ISO6 6 cm are detailed below:
| Parameter | Specification |
|---|---|
| Reference | 830003M |
| Size / model | ISO6 |
| Length | 6 cm (60 mm) |
| Material | Medical plastic, rigid and anatomical |
| Use | Oropharyngeal airway maintenance |
| Application | Emergency care, anaesthesia and resuscitation |
| Function | Prevents tongue obstruction and ensures airflow |
| Indication | Older children, adolescents of small build and reduced anatomies |
| Presentation | Unit |
| Type of use | Single-use (disposable) |
This reference is part of the Cahnos range of standard-rigidity Guedel airways, available in progressive sizes to cover all patient profiles:
| Reference | Size | Length |
|---|---|---|
| 830001M | ISO4 | 4 cm |
| 830002M | ISO5 | 5 cm |
| 830003M | ISO6 | 6 cm |
| 830010M | ISO7 | 7 cm |
| 830020M | ISO8 | 8 cm |
| 830030M | ISO9 | 9 cm |
| 830040M | ISO10 | 10 cm |
| 830050M | ISO11 | 11 cm |
| 830060M | ISO12 | 12 cm |
4. Equivalences and Cross-References
The ISO6 size (6 cm / 60 mm) follows the length-based coding system in centimetres used by most manufacturers in the sector for oropharyngeal airways (sizes 0 to 12), which facilitates direct replacement in crash carts and standardised airway protocols. In the Cahnos catalogue, the same size is available in a flexible material version with an atraumatic tip (ref. SGU241060), recommended for paediatric patients or those with sensitive oral tissues; and in a high-consumption sterile presentation in a box of 50 units (ref. 5000), the most economical alternative for high-volume programmes in clinical settings. This reference, together with its adjacent sizes, completes the comprehensive provision for anaesthesia, emergency, ICU or out-of-hospital emergency care services.
5. Selection tips and variants of interest
To choose the correct Guedel airway size, measure the distance between the labial commissure and the angle of the patient’s mandible: the length of the airway should approximate this distance without exceeding it. As a reference, the ISO6 size (6 cm) fits older children, adolescents of small build and reduced anatomies; smaller patients may require the ISO5 (ref. 830002M), and larger patients the ISO7 (ref. 830010M) or ISO8 (ref. 830020M). It is recommended to lubricate the airway before insertion and place it with a 180-degree rotation to minimise trauma. In patients with fragile mucosa, consider the flexible material version (ref. SGU241060), while for high-volume provisions the sterile presentation in a box of 50 units (ref. 5000) is the most cost-effective option. Consult our technical-commercial team to assess volumes, supply conditions and the configuration of airway kits adapted to your service.





Reviews
There are no reviews yet.