We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Endotracheal Tube ENDOSID Magill 4 mm Without Cuff (Ref. 840040) – Paediatric and Neonatal Intubation

10,16 €

Endotracheal Tube ENDOSID Magill 4 mm (Ref. 840040), a single-use device for safe intubation in paediatric and neonatal patients with reduced-calibre airways. Its Magill curvature, with curved tip and without cuff, facilitates controlled and atraumatic insertion while sealing is achieved by the natural fit of the size against the tracheal mucosa, minimising the risk of pressure injury. Made of transparent, flexible and resistant medical material, with a standard 15 mm connector compatible with most circuits and ventilators on the market. Presentation in a box of 10 units. Ideal for paediatric operating theatre, NICU and emergency services. Available from Cahnos with fast delivery.

International shipping. Import duties and taxes are payable by the recipient.

Reference
840040

Description

1. Introduction

The Endotracheal Tube ENDOSID Magill 4 mm (Ref. 840040) is a single-use medical device designed for the safe management of the airway in paediatric and neonatal patients with reduced-calibre airways. Its classic Magill design, with curved tip and without cuff, offers the anaesthesia, intensive care and emergency professional a precise, reliable and easy-to-handle solution in the most demanding environments, such as the paediatric operating theatre, the neonatal intensive care unit (NICU) and emergency services.

2. Technical Explanation

The endotracheal tube is inserted into the trachea to ensure a patent airway and allow mechanical ventilation or administration of anaesthesia. The Magill configuration, with its characteristic proximal curvature, facilitates insertion in small patients and allows the tip to be directed towards the glottic opening with greater control. As it has no inflation cuff, sealing is achieved by the natural fit of the calibre against the tracheal mucosa, which minimises the risk of pressure injury in immature airways and avoids compression of the mucosa. Its transparent material allows the patency of the circuit to be verified at all times during placement, and its atraumatic tip favours a direct passage without deviations of the airflow.

3. Technical Specifications

The technical features of this endotracheal tube are summarised in the following table:

Parameter Specification
Reference 840040
Inner diameter 4 mm
Type Magill, curved tip, cuffless
Inflation cuff No
Material Medical grade, transparent, flexible and durable
Tip Atraumatic, curved
Connector 15 mm standard (ISO 5356-1)
Function Maintain a patent airway and allow ventilation or anaesthesia
Clinical application Paediatric and neonatal intubation, narrow airways
Use environments Paediatric operating theatre, NICU and emergency services
Presentation Box of 10 units
Use Disposable, single-use

This tube is part of the standard ENDOSID Magill range, available in the following sizes:

Gauge Reference
2 mm 840020
2.5 mm 840025
3 mm 840030
3.5 mm 840035
4 mm 840040
4.5 mm 840045
5 mm 840050
5.5 mm 840055
6 mm 840060

4. Equivalences and Cross-References

This tube is part of the ENDOSID airway management family from Cahnos. As complementary references of the same 4 mm size: the version with cuff and Murphy eye corresponds to Ref. 841040, the version without cuff and without Murphy eye to Ref. 842040, and the version without cuff with Murphy eye to Ref. 843040. For rapid intubation environments, the 4 mm emergency kit (Ref. 845040) integrates this type of device with the essential accessories. Thanks to its standard 15 mm connector according to ISO 5356-1, it is compatible with virtually all circuits and ventilators on the market and can be replaced by cuffless endotracheal tubes of identical size from other manufacturers (e.g. ETAN40C02, PB-212040U, 44.000.10.040, 44.000.11.040). It is always recommended to verify the size and configuration (with or without cuff and with or without Murphy eye) before replacing one reference with another.

5. Selection tips and variants of interest

The selection of the size should be based on the patient’s age and weight: for neonates and premature infants, sizes from 2 to 3.5 mm are used; for infants and young children, sizes from 3.5 to 5 mm; and for older children or narrow airways, sizes from 5.5 to 6 mm. This standard Magill version without cuff is particularly indicated for short procedures and when an atraumatic insertion without additional elements in the lumen is desired. If there is a risk of distal obstruction by secretions or kinking, consider the version with Murphy eye (Ref. 843040); in long-duration procedures or when an airtight seal of the airway is required, consider the cuffed variant of the same family (Ref. 841040). To complete its equipment, ENDOSID also offers compatible intubation stylets (Ref. 844025, for tubes from 2.5 to 4 mm) and emergency kits in all sizes. Consult our technical-commercial team for the approval of references and large-volume orders.

Additional information

Reference

840040

Inner diameter

4 mm

Product type

Magill, curved tip

Balloon

Without cuff

Material

Medical grade, transparent, flexible and durable

Connector

15 mm standard (ISO 5356-1)

Application

Paediatric and neonatal intubation, narrow airways

Presentation

Box of 10 units

Use

Disposable, single-use

Scope of use

Paediatric operating theatre, NICU and emergency services

Reviews

There are no reviews yet.

Be the first to review “Endotracheal Tube ENDOSID Magill 4 mm Without Cuff (Ref. 840040) – Paediatric and Neonatal Intubation”

Your email address will not be published. Required fields are marked *