Description
1. Introduction
The Endotracheal Tube ENDOSID Magill 3 mm (Ref. 840030) is a single-use medical device designed for the safe management of the airway in neonates, infants and paediatric patients with reduced-calibre airways. Its classic Magill design, with a pre-curved shape and no inflation cuff, offers anaesthesia, intensive care and emergency professionals a precise, reliable and easy-to-handle solution in the most demanding environments, such as the neonatal intensive care unit (NICU), the paediatric operating theatre and emergency departments. A trusted choice for clinical teams that need maximum control and safety in especially vulnerable patients.
2. Technical Explanation
The endotracheal tube is inserted into the trachea to secure a patent airway and allow mechanical ventilation or administration of anaesthesia. The Magill configuration, with its characteristic proximal curvature, facilitates insertion in small patients and allows the tip to be directed towards the glottic opening with greater control, both orally and nasally. As it has no inflation cuff, sealing is achieved by the natural fit of the calibre against the tracheal mucosa, which minimises the risk of pressure injury in immature airways and avoids compression of the mucosa. Its transparent material allows the patency of the circuit to be verified at all times during placement, while the radiopaque contrast line facilitates radiographic control of the tube position.
3. Technical Specifications
The technical features of the Endotracheal Tube ENDOSID Magill 3 mm are summarised in the following table:
| Parameter | Specification |
| Reference | 840030 |
| Inner diameter | 3 mm |
| Type | Magill, curved tip, cuffless |
| Inflation cuff | No (sealing by natural fit of the calibre) |
| Material | Medical grade, transparent, flexible and resistant (PVC) |
| Latex | Free of natural rubber latex |
| Radiopacity | Yes, radiopaque contrast line for imaging control |
| Connector | 15 mm standard (ISO 5356-1) |
| Clinical application | Neonatal and paediatric intubation; narrow airways |
| Use environments | NICU, paediatric operating theatres and emergency departments |
| Presentation | Box of 10 units |
| Use | Disposable, single-use |
The standard ENDOSID Magill family (series 840xxx) covers a complete range of sizes for neonatal and paediatric intubation:
| Gauge | Reference |
| 2 mm | 840020 |
| 2.5 mm | 840025 |
| 3 mm | 840030 |
| 3.5 mm | 840035 |
| 4 mm | 840040 |
| 4.5 mm | 840045 |
| 5 mm | 840050 |
| 5.5 mm | 840055 |
| 6 mm | 840060 |
4. Equivalences and Cross-References
This tube is part of the ENDOSID airway management family from Cahnos, with a standard Magill design without a cuff. As complementary references of the same 3 mm size: the version without a cuff and without a Murphy eye corresponds to Ref. 842030, the version without a cuff with a Murphy eye to Ref. 843030, and the version with a cuff and Murphy eye to Ref. 841030. For rapid intubation settings, the family also includes emergency kits (series 845xxx) that integrate this type of tube with the essential accessories. The standard 15 mm connector complies with ISO 5356-1, so the device is compatible with the vast majority of circuits and ventilators on the market and can be replaced by uncuffed Magill endotracheal tubes of identical size from other manufacturers (e.g. 100/111/030 or 100/141/030). It is always recommended to verify the size and configuration (with or without cuff and with or without Murphy eye) before replacing one reference with another.
5. Selection tips and variants of interest
The selection of the size should be based on the patient’s age and weight: for neonates and premature infants, sizes from 2 to 3.5 mm are used; for infants and young children, sizes from 3.5 to 5 mm; and for older children or narrow airways, sizes from 5.5 to 6 mm. This standard cuffless version is particularly indicated when minimising trauma to the immature tracheal mucosa is desired; if there is a risk of distal obstruction due to secretions or kinking, consider the version with a Murphy eye (Ref. 843030). In long-duration procedures or when an airtight seal of the airway is required, consider the cuffed variant of the same family (Ref. 841030). To complete your equipment, ENDOSID also offers intubation guide stylets and emergency kits in all sizes. Consult our technical-commercial team for the approval of references and large-volume orders.