Description
1. Commercial Introduction
The CH 7.0 mm cuffed endotracheal tube is the airway solution that your anaesthesia, intensive care, emergency and resuscitation department needs to ensure rapid, safe and reliable intubation in adult patients. Made of plastic material, it combines a sealing cuff with a one-way valve and a standard connector conforming to ISO standards, offering stable positive-pressure ventilation from the outset. It is supplied individually packaged in sterile format, ready for use in the intubation trolley, the operating theatre or the critical care unit. At Cahnos we manage this consumable item, with technical and commercial support for the approval of your tender. For large orders you can request a quote.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea below the vocal cords, conducting gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs through the standard ISO connector.
The sealing cuff is inflated via the pilot balloon equipped with a one-way valve, which seals the tracheal lumen, prevents gas leaks and reduces the risk of aspiration of secretions during positive-pressure ventilation. The reference marks and radiopaque marking allow radiographic verification of the depth and correct position of the tube, while the non-traumatic tip minimises the risk of mucosal injury during insertion.
3. Technical Specifications
The specifications correspond to the data published in the manufacturer’s catalogue for this reference:
| Manufacturer reference | 11814102011 / BRL11814102011 |
| Manufacturer | Boscarol |
| Type | Endotracheal tube with cuff (cuffed), in plastic material |
| Access route | Oral (orotracheal) |
| Gauge | CH 7.0 mm |
| Size | Ø 7.0 x 310 mm |
| Sleeve | With sealing cuff (cuff) |
| Valve | Unidirectional |
| Connector | Standard in accordance with ISO standards |
| Marking | Reference marks and radiopaque line (radiopaque) |
| Tip | Non-traumatic |
| Presentation | Individually packaged sterile |
| Sterilisation | Sterile supply |
| Use | Single-use, non-reusable |
4. Equivalences and Cross-References
The reference BRL11814102011 / 11814102011 corresponds to the manufacturer’s catalogue code and is supplied by Cahnos. For this exact configuration (endotracheal tube with cuff, plastic material, CH 7.0 mm, Ø 7.0 x 310 mm) we do not have a table of equivalences validated by the manufacturer in the official sources consulted. The tube falls, by clinical indication, into the same functional category as the adult-size cuffed endotracheal tubes available on the market (manufacturers such as Teleflex, Intersurgical, ICU Medical or P. J. Dahlhausen, among others), but it is essential to compare sheet by sheet the diameter, total length, material, valve type and regulatory classification before considering any substitution. Consult the technical department of Cahnos to validate equivalences in specifications or tenders; these options should not be treated as interchangeable 1:1 without prior technical verification.
5. Selection tips and variants of interest
The CH 7.0 mm calibre is a size commonly used in adult patients, frequently indicated for adult women and adults of medium build; as a general clinical practice guideline, tubes of 7.0 to 10.0 mm are used in adults depending on build and airway assessment, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol. In the Cahnos catalogue you will find the adjacent sizes of the same family (CH 8.0 mm, ref. BRL11814102013, as well as the oronasal range ETAN…C02) to complete the intubation trolley stock.
Before insertion, check the integrity of the cuff, the pilot balloon and the one-way valve, as well as the patency of the lumen and the sterility expiry date. Inflate the cuff with a syringe and maintain a sealing pressure within the usual clinical range (ideally 20–30 cmH₂O; check the department’s protocol) to minimise the risk of pressure injury to the tracheal mucosa. If your protocol requires kink-resistant reinforcement, tubes with a subglottic suction lumen or other variants, contact the technical-commercial team at Cahnos to consider the most suitable alternative for your department. Single-use device: do not re-sterilise or reuse; dispose of it after removal according to the centre’s healthcare waste management protocols.