We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Miller laryngoscope blade size 2 with conventional light (C.L.) in stainless steel, reusable (Ref. RIA53124 | SKU BRLRIA53124)

32,47 €

Laryngoscope blade (blade) of Miller straight profile, size 2, with conventional lighting system (C.L.) in stainless steel. Designed for direct laryngoscopy and orotracheal intubation in older children and small-stature adults, its straight geometry allows direct elevation of the epiglottis and exposure of the glottis for a clear view of the glottic plane. Reusable, robust instrument suitable for hospital cleaning, disinfection and sterilisation cycles; ideal for anaesthesiology, emergency, critical care, resuscitation and airway trolleys. Class I medical device in accordance with Regulation (EU) 2017/745 (MDR). References RIA53124 / BRLRIA53124. For large orders you can request a quote: request terms and availability from our technical-commercial team.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLRIA53124

Description

1. Commercial Introduction

The Miller straight-profile laryngoscope blade, size 2, with conventional light system (C.L.) is the reusable stainless steel option for direct laryngoscopy and orotracheal intubation. Designed for anaesthesiology services, emergency departments, critical care units, resuscitation, operating theatres and airway trolleys, it offers a robust metal construction with a reliable fit on the laryngoscope handle, ensuring stability and precision in every procedure. Being reusable, it provides an excellent cost-benefit ratio in high-turnover healthcare settings. For large orders you can request a quote: contact the technical-commercial department of Cahnos to request terms and availability.

2. Technical explanation of the equipment and procedure

Direct laryngoscopy with a Miller-type blade is the classic straight-profile technique for endotracheal intubation: the straight blade is inserted and directly lifts the epiglottis, exposing the glottis and facilitating the passage of the endotracheal tube. This technique is particularly useful in patients with limited oral opening or laryngeal anatomy that requires a direct view of the glottic plane. Size 2 is indicated for older children and small-stature adults, where an intermediate-length blade provides the reach and exposure needed for optimal visualisation.

This blade uses a conventional lighting system (C.L.): the light is generated in the handle and projected directly onto the working field, without the need for a fibre-optic guide. Made entirely of stainless steel, it is a highly robust reusable device with excellent durability in high-turnover healthcare environments, as it withstands the usual hospital cleaning, disinfection and sterilisation cycles while maintaining full mechanical and lighting performance.

3. Technical Specifications

Reusable Miller straight-profile laryngoscope blade (blade), size 2, with conventional lighting (C.L.) and stainless steel body, designed for direct laryngoscopy and orotracheal intubation.

Reference Description
RIA53124 CONVENTIONAL LIGHT MILLER BLADE SIZE 2 – Manufacturer’s original reference
BRLRIA53124 CONVENTIONAL LIGHT MILLER BLADE SIZE 2 – SKU Cahnos (same product)
Characteristic Specification
Manufacturer Boscarol
Product type Reusable laryngoscope blade
Profile Miller (straight)
Size 2
Material Stainless steel
Illumination system Conventional light (C.L.)
Target population Older children and small-stature adults
Reuse Yes (reusable)
Device class Class I medical device
Regulatory standard Regulation (EU) 2017/745 (MDR)
Category Respiration and Emergency

4. Equivalences and Cross-References

This blade is identified in the manufacturer’s catalogue with reference RIA53124, which in Cahnos corresponds to SKU BRLRIA53124 (same product, dual coding). It is part of the manufacturer’s range of conventional light (C.L.) Miller straight-profile blades, available in several sizes (0, 1, 2, 3 and 4), as well as in the fibre-optic (O.F.) version of the same family in sizes 0 to 3.

Within the same catalogue there are verified related references: the C.L. Miller blade size 3 (RIA53126 / BRLRIA53126), the C.L. Miller blade size 4 (RIA53128 / BRLRIA53128), the Miller fibre-optic blades (e.g. size 2, RIA53324 / BRLRIA53324; size 3, RIA53326 / BRLRIA53326), the McIntosh-profile blades in fibre-optic (e.g. size 2, RIA53224 / BRLRIA53224), the disposable Miller 2 blades with fibre-optic (RIA53436 / BRLRIA53436), the C.L. set of 3 Miller blades 1-2-3 (RIA53104 / BRLRIA53104) and the lighting spare parts of the range (C.L. bulbs ref. RIA53180 and RIA53182). There is no 1:1 equivalence table validated by the manufacturer against third-party codes (e.g. Heine, Penlon, Riester or KaWe); before replacing blades of another brand it is essential to verify the fit of the connection (standard ISO 7376), the profile and the size with the corresponding laryngoscope handle, and to check the reference with the technical-commercial department of Cahnos before use in tendering.

5. Selection tips and variants of interest

Select the blade size according to the patient’s age and anatomy: size 0 is reserved for neonates, size 1 for infants and young children, size 2 (this reference) for older children and small-stature adults, size 3 for most adult patients and size 4 for large-stature or large-build adults. The Miller straight profile is especially recommended when direct elevation of the epiglottis is preferred; for patients where indirect elevation by resting on the vallecula is preferred, the McIntosh series constitutes a complementary alternative within the same family.

To fully equip your airway trolley, combine several sizes of the same C.L. family and use a laryngoscope handle compatible with conventional light blades, keeping spare bulbs (ref. RIA53180 for small blade and RIA53182 for large blade) so that the equipment is always operational. Always verify the correct alignment and blade-handle fit before each procedure and respect the recommended cleaning, disinfection and sterilisation cycles for stainless steel instruments. For complete equipment, tenders or special supply conditions, contact the technical-commercial team of Cahnos.

Additional information

Product type

Reusable laryngoscope blade

Profile

Miller (straight)

Size

2

Illumination system

Conventional light (C.L.)

Target population

Older children and small-stature adults

Device class

Class I medical device

Regulatory standard

Regulation (EU) 2017/745 (MDR)

Manufacturer reference

RIA53124

Material

Stainless steel

Tipo uso

Reusable

Documentation

Reviews

There are no reviews yet.

Be the first to review “Miller laryngoscope blade size 2 with conventional light (C.L.) in stainless steel, reusable (Ref. RIA53124 | SKU BRLRIA53124)”

Your email address will not be published. Required fields are marked *