Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality is the reference choice for the professional who needs a synthetic absorbable thread with predictable behaviour, excellent handling and rapid strength loss, designed for fast-healing tissues. Its configuration with ⅜ circle needle, body and triangular point with reverse cutting edge of 19 mm, USP gauge 3/0 and colourless thread 75 cm makes it a versatile solution for soft tissue approximation, ligatures and ophthalmic surgery.
Presented in a box of 12 sterile units, it guarantees batch traceability and reduces handling in the operating theatre, optimising surgical times. Excellent value for money for hospitals, clinics, ambulatory surgery and B2B supply contracts.
2. Technical explanation
Polyglactin 910 (PGLAR) is an absorbable synthetic copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure that provides flexibility, low shape memory, smooth passage through tissue and firm, secure knot tying.
In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50% of the initial tensile strength at 5 days and loses it completely at 14 days, making it ideal for superficial tissues and temporary approximations where material removal is not required.
The ⅜ circle needle with body and triangular reverse cutting point of 19 mm (DS19) offers effective penetration in firm tissues and skin with minimal tissue trauma, ideal for dermatology, minor surgery and ophthalmic procedures. The colourless thread facilitates maximum discretion on the surgical field. Sterilisation by gamma radiation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided multifilament, undyed |
| Quality | Prime |
| Gauge | USP 3/0 (metric 2) |
| Thread length | 75 cm |
| Needle shape | 3/8 circle (135°) |
| Needle body and point | Triangular, reverse cutting |
| Needle size | 19 mm (DS19) |
| Absorption mechanism | Hydrolysis, 40–45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Colour | Colourless |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Factory reference | P2L22DS1930 |
| SKU | AMP2L22DS1930 |
| Commercial format | Box of 12 units |
Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days, by hydrolysis (predictable and uniform rate) |
4. Equivalences and Cross-References
Rapid absorption polyglactin 910 (low molecular weight) is one of the most widespread absorbable multifilament categories in the surgical market. This reference shares material, USP gauge 3/0, ⅜ circle curvature, triangular reverse cutting needle of 19 mm, colourless thread of 75 cm and rapid absorption profile with the equivalent line of the leading manufacturer in the sector. Only the reference whose full code and attributes have been verified in the official catalogue of the manufacturer and authorised distributors is included:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | W9931 (EMEA, 3/8 circle reverse cutting needle 19 mm, 75 cm) | Comparable by category (not interchangeable 1:1) | Same material and rapid absorption (≈42 days), USP gauge 3/0, colourless braided thread of 75 cm and ⅜ circle reverse cutting needle of 19 mm match in dimensions. They differ in needle nomenclature, braid coating (VICRYL RAPIDE is coated) and manufacturer. Code confirmed in official Ethicon EMEA catalogue and authorised distributors (box of 12 units). |
Other equivalent lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; they are not included in the table as no verified code is available for the exact combination USP 3/0 / 19 mm needle / reverse cutting / 75 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. No equivalence table validated by the manufacturer exists; consult the technical department before use in a tender.
5. Selection tips and variants of interest
To choose the correct suture, verify three parameters: USP gauge (this model, USP 3/0, is suitable for skin, subcutaneous tissue, mucosa and soft tissue approximation with short-term support), needle geometry (3/8 circle with reverse cutting for firm and thin tissues, indicated in minor surgery, dermatology and ophthalmology) and thread length (75 cm for controlled suturing manoeuvres).
Within the same PGLAR Polyglactin 910 RAPID family with DS triangular needle, Cahnos offers complementary gauges: USP 4/0 and USP 5/0 with DS19 needle (SKU AMP2L22DS1940 and AMP2L22DS1950), USP 3/0 and USP 5/0 with DS16 needle (AMP2L22DS1630 and AMP2L22DS1650), USP 4/0 and USP 6/0 with DS12 needle (AMP2L22DS1240 and AMP2L22DS1260) and USP 2/0 with DS30 needle (AMP2L22DS3020). If the protocol prefers a taperpoint needle in larger gauges, consider the HR40 family with 90 cm thread. The colourless version offers maximum discretion in the field; if greater visibility is required, the same configuration in violet can be considered on request.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.