Absorbable Multifilament Polyglactin 910 RAPID Prime Suture · ⅜ Circle Reverse Cutting Needle DS24 mm · USP 2/0 · Undyed · 2 x 75 cm · Box of 12 units (Ref. P2L22DS2420.2)

85,40 €

Absorbable multifilament suture PREMISUT RAPID Prime (Polyglactin 910 – PGLAR) with a ⅜ circle needle, body and triangular reverse cutting point 24 mm (DS24), USP gauge 2/0 (metric 3) and undyed fluted thread in double format 2 x 75 cm. Predictable absorption by hydrolysis in 40-45 days, with tensile strength retention of 50% at 5 days and 0% at 14 days: short-term support, ideal for closure of skin, mucous membranes and superficial fast-healing tissues without suture removal. Sterilised by gamma radiation, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Factory ref. P2L22DS2420.2 · Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS2420.2

Description

1. Commercial Introduction

The absorbable multifilament suture PGLAR (Polyglactin 910) in RAPID variant and PRIME quality from the PREMISUT RAPID range is the reference for accelerated absorption surgical closure for general and ambulatory surgery operating theatres, emergency departments, ophthalmology clinics and B2B purchasing centres that need a braided, flexible thread with early and totally predictable loss of strength. Its ⅜ circle reverse cutting needle of 24 mm perforates skin and mucous membranes with precision without tearing the edge, while the colourless thread in double format 2 x 75 cm offers maximum discretion in the field and greater yield per pack. Practical and cost-effective presentation in a box of 12 units.

2. Technical explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure coated with a grooved finish that favours sliding, very smooth handling and a firm, secure knot. In the RAPID variant (low molecular weight), the thread loses tensile strength in an accelerated and programmed manner: it retains 50% of the initial resistance at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery. The ⅜ circle needle (135°) with improved reverse cutting triangular point traverses firm tissues with precise entry and exit, minimising trauma. Product sterile by gamma radiation, single-use and not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS2420.2 · SKU AMP2L22DS2420.2)

Parameter Specification
Material Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant
Thread structure Braided coated multifilament, fluted finish
Quality Prime (range PREMISUT RAPID Prime)
Gauge USP 2/0 (metric 3; approximate diameter 0.30 – 0.339 mm according to Pharmacopoeia)
Thread colour Colourless
Thread length 2 x 75 cm (double format)
Needle shape ⅜ circle (3/8, 135°)
Needle body Triangular
Needle tip Reverse cutting
Needle size DS24 (24 mm)
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Tensile strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order 30 boxes)
Factory reference P2L22DS2420.2
SKU Cahnos AMP2L22DS2420.2

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable rate)

Absorption by hydrolysis with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.

4. Equivalences and Cross-References

Rapid absorption polyglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line. The analysed reference shares material, accelerated absorption profile (≈42 days), USP 2/0 gauge, colourless 75 cm thread, ⅜ circle curvature and reverse cutting point with the homologous lines in the sector. Only codes whose attributes have been verified in authorised distribution catalogues are included; no reference should be considered 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9933 – USP 2/0, PS needle 26 mm, ⅜ circle, reverse cutting, 75 cm, box of 12 Comparable by category (not interchangeable 1:1) Same material, rapid absorption (≈42 days), USP 2/0 gauge, ⅜ curvature, reverse cutting and 75 cm length; they differ in needle size (26 mm PS vs. DS24 of 24 mm) and format (single thread vs. double 2 x 75 cm). Code confirmed in authorised distributor catalogues.
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9938 – USP 2/0, needle 38 mm, ⅜ circle, reverse cutting, 75 cm, box of 12 Comparable by category (not interchangeable 1:1) Same material, rapid absorption, USP 2/0 gauge, colourless 75 cm thread and ⅜ reverse cutting needle; differs in needle size (38 mm vs. DS24 of 24 mm) and double format. Code confirmed in authorised distributor catalogues.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Homologous ranges in the rapid absorption segment include Safil Quick / NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category by material and absorption profile, although for the exact combination USP 2/0 / DS24 reverse cutting needle / double 75 cm thread, their specific codes must be confirmed with the manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) offers an optimal balance between strength and handling, indicated for skin, subcutaneous tissue, mucous membranes, approximation of soft tissues and ligation of small and medium-calibre vessels. The ⅜ circle needle with reverse cutting triangular point is the usual choice for skin closure and firm tissues: it penetrates with minimal resistance and avoids tearing the edge, also being widely used in ophthalmic surgery. The double 2 x 75 cm format maximises yield per pack. Within the same PGLAR RAPID Prime range, Cahnos offers complementary configurations: AMP2L22HR2220.2 (USP 2/0 with HR22 conical cylindrical needle, colourless, 2 x 75 cm), AM2L2-15020 (USP 2/0 without needle, colourless, 150 cm), AM2L2-3.4520 (USP 2/0 without needle, colourless, 3 x 45 cm), AM2L22HS1730 (USP 3/0 with HS 17 reverse cutting needle) and AM2L22HRT2630 (USP 3/0 with trocar point). The colourless version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand. For longer tensile support, consider the PGLA family with standard absorption (56–72 days). Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and store in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalences from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR) – copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant

Thread structure

Braided coated multifilament, fluted finish

Quality

Prime (range PREMISUT RAPID Prime)

Gauge

USP 2/0 (metric 3; diameter 0.30-0.339 mm)

Thread length

2 x 75 cm (double format)

Needle shape

3/8 circle (135°)

Needle body

Triangular

Needle tip

Reverse cutting

Needle size

DS24 (24 mm)

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Presentation

Box of 12 units (minimum order 30 boxes)

Manufacturer reference

P2L22DS2420.2

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

DS 24

Usp

2/0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)