We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime — 1/2 Circle Cylindrical Needle Taper Point Conical HR40 mm, USP 0, Colourless Thread 75 cm (Box of 12 units)

Original price was: 44,63 €.Current price is: 33,40 €.

Absorbable multifilament suture PREMISUT RAPID (PGLAR) of Polyglactin 910 in Prime quality, with ½ circle needle with cylindrical body and taper point conical tip of 40 mm (HR40), USP 0 gauge and colourless grooved thread of 75 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50 % of tensile strength at 5 days and loses all its strength at 14 days. Sterile by gamma radiation, with minimal tissue reaction and secure knot. Indicated for soft tissue approximation, ligatures and ophthalmic surgery. Factory reference P2L22HR4010 · Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22HR4010

Description

1. Commercial Introduction

The absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality (PREMISUT RAPID range) is the high-performance surgical reference for hospitals, ophthalmology clinics, purchasing groups and surgical services in the B2B channel. It offers a braided, flexible thread with early, predictable and fully documented loss of strength, designed for tissues that heal quickly and only require short-term support. An excellent balance between clinical performance, knot security and cost per pack, in a box presentation of 12 units.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented here in its low molecular weight variant (RAPID) which accelerates the loss of strength and mass compared with conventional polyglactin 910. Its braided multifilament structure with a grooved finish provides very smooth handling, controlled sliding and firm knot tying.

Absorption occurs by hydrolysis, without depending on tissue enzymes, over a predictable period of 40 to 45 days and with minimal tissue reaction. The tensile strength retention profile is 50 % at 5 days and 0 % at 14 days, making it especially indicated for skin and mucosa approximation, ligatures, episiotomies, paediatric surgery and ophthalmic surgery. The ½ circle needle with cylindrical body and taper point conical tip penetrates soft tissues by separating the fibres without tearing them. The product is supplied sterile by gamma radiation, is single-use and cannot be re-sterilised.

3. Technical Specifications

Thread material Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID)
Thread structure Braided multifilament, grooved finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 0 (metric 3.5; approx. diameter 0.35–0.399 mm)
Thread colour Colourless
Needle shape ½ circle
Needle body Cylindrical
Needle tip Taperpoint
Needle size HR 40 mm
Thread length 75 cm
Absorption mechanism Hydrolysis
Absorption period 40–45 days
Tensile strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units
Factory reference P2L22HR4010
SKU Cahnos AMP2L22HR4010

Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50 %
14 days 0 %

Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.

4. Equivalences and Cross-References

Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widely used synthetic absorbable multifilament materials with rapid absorption on the market. The reference analysed is comparable at category level with braided polyglactin 910 RAPID sutures from other manufacturers, both in composition and in absorption and tension retention profile. Only the reference whose code and attributes have been verified in industry sources (official manufacturer website and authorised distributors) is included:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) V9580H Comparable by category (not interchangeable 1:1) Same material (rapid-absorption polyglactin 910), USP 0 gauge, colourless thread and ½ circle conical needle of 40 mm; they differ in thread length (90 cm vs 75 cm), exact point geometry (CT Plus) and coating. Verified on official Ethicon EMEA website.

As homologous reference ranges in the sector, the braided rapid-absorption polyglactin 910 sutures from B. Braun (Safil Quick type line) are included, as well as the absorbable braided lines from DemeTECH (DemeCRYL Fast) and SMI (Surgicryl Fast Absorb), whose specific codes for the exact combination USP 0 / HR 40 mm conical needle / 75 cm thread must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying on each official data sheet the USP 0 gauge (metric 3.5), the ½ circle curvature, the type and size of needle (taper point conical 40 mm), the thread length (75 cm) and the colourless colour.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue and the necessary gauge according to the anatomical area. The USP 0 gauge with a 40 mm taper point conical needle is a common choice for skin and mucosa approximation, ligatures and ophthalmic surgery, with early loss of strength that avoids suture removal in many indications. Within the same PGLAR RAPID PRIME range with cylindrical needle and conical point, Cahnos offers complementary configurations:

  • AM2L22HR4010: same standard configuration USP 0, HR 40 mm needle, 75 cm thread (standard quality, same gauge and geometry).
  • AMP2L23HR4010: Prime quality USP 0 with HR 40 mm needle and 90 cm thread (greater length per unit).
  • AMP2L23HR4001: same HR 40 mm geometry in USP 1 gauge, 90 cm thread (greater initial strength).
  • AMP2L22HR4020: Prime quality USP 2/0 with HR 40 mm needle and 75 cm thread (finer gauge).
  • AMP2L23HR4010.2: Prime quality USP 0 with HR 40 mm needle in double format 2×90 cm (greater yield per unit).

All references are supplied in a box of 12 units. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide), RAPID variant

Thread structure

Multifilament braided fluted

USP size

0 (metric 3.5)

Needle body

Cylindrical

Needle tip

Taperpoint

Absorption mechanism

Hydrolysis

Sterilisation

Gamma radiation

Presentation

Box of 12 units

Manufacturer reference

P2L22HR4010

Medida de aguja

HR 40

Usp

0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime — 1/2 Circle Cylindrical Needle Taper Point Conical HR40 mm, USP 0, Colourless Thread 75 cm (Box of 12 units)”

Your email address will not be published. Required fields are marked *