Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality (PREMISUT RAPID range) is the high-performance surgical reference for hospitals, ophthalmology clinics, purchasing groups and surgical services in the B2B channel. It offers a braided, flexible thread with early, predictable and fully documented loss of strength, designed for tissues that heal quickly and only require short-term support. An excellent balance between clinical performance, knot security and cost per pack, in a box presentation of 12 units.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented here in its low molecular weight variant (RAPID) which accelerates the loss of strength and mass compared with conventional polyglactin 910. Its braided multifilament structure with a grooved finish provides very smooth handling, controlled sliding and firm knot tying.
Absorption occurs by hydrolysis, without depending on tissue enzymes, over a predictable period of 40 to 45 days and with minimal tissue reaction. The tensile strength retention profile is 50 % at 5 days and 0 % at 14 days, making it especially indicated for skin and mucosa approximation, ligatures, episiotomies, paediatric surgery and ophthalmic surgery. The ½ circle needle with cylindrical body and taper point conical tip penetrates soft tissues by separating the fibres without tearing them. The product is supplied sterile by gamma radiation, is single-use and cannot be re-sterilised.
3. Technical Specifications
| Thread material | Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID) |
| Thread structure | Braided multifilament, grooved finish |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 0 (metric 3.5; approx. diameter 0.35–0.399 mm) |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | HR 40 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40–45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Factory reference | P2L22HR4010 |
| SKU Cahnos | AMP2L22HR4010 |
Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widely used synthetic absorbable multifilament materials with rapid absorption on the market. The reference analysed is comparable at category level with braided polyglactin 910 RAPID sutures from other manufacturers, both in composition and in absorption and tension retention profile. Only the reference whose code and attributes have been verified in industry sources (official manufacturer website and authorised distributors) is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | V9580H | Comparable by category (not interchangeable 1:1) | Same material (rapid-absorption polyglactin 910), USP 0 gauge, colourless thread and ½ circle conical needle of 40 mm; they differ in thread length (90 cm vs 75 cm), exact point geometry (CT Plus) and coating. Verified on official Ethicon EMEA website. |
As homologous reference ranges in the sector, the braided rapid-absorption polyglactin 910 sutures from B. Braun (Safil Quick type line) are included, as well as the absorbable braided lines from DemeTECH (DemeCRYL Fast) and SMI (Surgicryl Fast Absorb), whose specific codes for the exact combination USP 0 / HR 40 mm conical needle / 75 cm thread must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying on each official data sheet the USP 0 gauge (metric 3.5), the ½ circle curvature, the type and size of needle (taper point conical 40 mm), the thread length (75 cm) and the colourless colour.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the necessary gauge according to the anatomical area. The USP 0 gauge with a 40 mm taper point conical needle is a common choice for skin and mucosa approximation, ligatures and ophthalmic surgery, with early loss of strength that avoids suture removal in many indications. Within the same PGLAR RAPID PRIME range with cylindrical needle and conical point, Cahnos offers complementary configurations:
- AM2L22HR4010: same standard configuration USP 0, HR 40 mm needle, 75 cm thread (standard quality, same gauge and geometry).
- AMP2L23HR4010: Prime quality USP 0 with HR 40 mm needle and 90 cm thread (greater length per unit).
- AMP2L23HR4001: same HR 40 mm geometry in USP 1 gauge, 90 cm thread (greater initial strength).
- AMP2L22HR4020: Prime quality USP 2/0 with HR 40 mm needle and 75 cm thread (finer gauge).
- AMP2L23HR4010.2: Prime quality USP 0 with HR 40 mm needle in double format 2×90 cm (greater yield per unit).
All references are supplied in a box of 12 units. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.