Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID from the PREMISUT range is the technical choice when the procedure requires short-term wound support, predictable reabsorption and excellent handling in the operating theatre. Its ½ circle needle with cylindrical body and conical Taperpoint tip of 22 mm passes through soft tissues separating the fibres without tearing them, with an atraumatic and controlled passage, while the colourless thread of 75 cm offers maximum discretion on the surgical field. A sterile, traceable and cost-effective solution in a box of 12 units, designed for operating theatres in general surgery, ophthalmology, emergency departments and B2B hospital supply contracts.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure with a grooved finish and lubricating coating that favours thread sliding, very smooth handling and a firm, secure knot. In the RAPID variant (low molecular weight polymer), the loss of tensile strength is accelerated and programmed: it retains 50 % of the initial resistance at 5 days and 0 % at 14 days, with complete absorption by hydrolysis between 40 and 45 days and minimal tissue reaction.
The ½ circle needle (160°) with conical Taperpoint tip minimises tissue trauma, making it especially suitable for approximation of skin and mucous membranes, subcutaneous tissue, ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery. The product is supplied sterile by gamma radiation, is single-use and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Thread material | Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Conical grooved (Taperpoint) |
| Needle size | HR 22 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| SKU Cahnos | AM2L22HR2220 |
Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50% of initial strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis, with predictable rate |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread rapid-action braided multifilament absorbable category on the market, whose international clinical reference is the VICRYL RAPIDE line (Ethicon / Johnson & Johnson MedTech). This reference shares material, absorption profile (≈42 days), tension retention (50 % at 5 days / 0 % at 14 days), USP 2/0 gauge, ½ circle curvature and colourless colour with the contrasted references indicated. None should be considered interchangeable 1:1 without validation from the technical department, since they differ in needle geometry:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | W9933 – USP 2/0, PS Prime needle 3/8 circle reverse cutting point of 26 mm, colourless thread of 75 cm | Comparable by category (not interchangeable 1:1) | Same material, rapid absorption profile (≈42 days), USP 2/0 gauge and thread length of 75 cm; the needle geometry differs (3/8 circle with reverse cutting of 26 mm versus ½ circle conical Taperpoint of 22 mm). Code confirmed in Ethicon catalogue and authorised distributors. |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | W9962 – USP 2/0, V-34 needle ½ circle Tapercut point of 36 mm, colourless thread of 90 cm | Comparable by category (not interchangeable 1:1) | Same material, rapid absorption and USP 2/0 gauge; shares ½ circle curvature but differs in the point (Tapercut versus conical Taperpoint), the needle size (36 mm versus 22 mm) and the thread length (90 cm versus 75 cm). Code confirmed in Ethicon catalogue and authorised distributors. |
As homologous ranges in the rapid absorption segment, Safil Quick / NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) appear, comparable by category, material and absorption profile; their specific codes for the exact combination USP 2/0 / conical Taperpoint needle of 22 mm / thread of 75 cm must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official sheet the USP 2/0 gauge (metric 3), the ½ circle curvature, the conical Taperpoint point of 22 mm, the thread length of 75 cm and the colourless colour.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucous membranes, approximation of soft tissues, ligation of small and medium-calibre vessels and ophthalmic surgery. The ½ circle needle with conical Taperpoint tip of 22 mm is especially recommended when an atraumatic passage is sought in lax and well-perfused tissues, without cutting effect. The RAPID variant loses tensile strength early, which in many indications avoids the removal of stitches.
Within the same PGLAR Polyglactin 910 RAPID range with cylindrical needle with conical point, Cahnos offers complementary configurations in the same USP 2/0 gauge: HR 26 mm needles (AM2L22HR2620), HR 30 mm (AM2L22HR3020), HR 36 mm (AM2L22HR3620) and HR 40 mm (AM2L22HR4020), in addition to the Prime quality version with identical dimensions (AMP2L22HR2220) and the double thread format 2 x 75 cm (AMP2L22HR2220.2). If the tissue is firmer, consider the variant with trocar point (HRT); if you prefer reverse cutting for dense skin and mucous membranes, consult the HS family. Sterile single-use product: check the integrity of the packaging and the expiry date before each intervention and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact the technical-commercial team of Cahnos.





Reviews