Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime is the high-performance reference for B2B supply to operating theatres, general and paediatric surgery departments, ophthalmology, emergency departments and purchasing centres that require an absorbable braided suture with rapid absorption, smooth handling and maximum knot security. It is supplied in a double format of 2 threads of 75 cm each, each mounted with a ½ circle needle with cylindrical body and Taperpoint grooved conical point of 30 mm (HR 30), USP 2/0 gauge and colourless thread, in a box of 12 units. A sterile, single-use product, designed for tissues that heal quickly and require short-term support, with an excellent balance between clinical performance and cost per pack.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish and lubricant coating (copolymer of polyglactin 370 and calcium stearate in a proportion ≤ 5%), which provides smooth passage through tissue, excellent handling and firm, secure knot tying. In the RAPID variant, the polymer is of low molecular weight and accelerates the loss of strength and mass: it retains 50% of the initial tensile strength at 5 days and loses all its strength at 14 days, with complete absorption by hydrolysis between 40 and 45 days and minimal tissue reaction.
The ½ circle needle with Taperpoint conical point passes through soft tissues by separating the fibres without tearing them, minimising tissue trauma. USP 2/0 gauge is the usual choice for approximation of skin, subcutaneous tissue, mucous membranes, ligation of small and medium-calibre vessels, as well as for ophthalmic surgery. The product is supplied sterile by gamma radiation, is single-use and does not allow re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
| Thread material | Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical grooved (Taperpoint) |
| Needle size | HR 30 mm |
| Length and configuration | 2 threads of 75 cm each (2 × 75 cm) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Factory reference | P2L22HR3020.2 |
| SKU Cahnos | AMP2L22HR3020.2 |
Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable on the market. This reference shares material, absorption profile (≈42 days), tensile strength retention (≈50% at 5 days / 0% at 14 days), USP 2/0 gauge, ½ circle curvature, colourless thread and 75 cm length with the rapid-absorption line of the leading company in the sector. Only the reference whose code and attributes have been verified in industry sources is included:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | W9933 | Comparable by category (not interchangeable 1:1) | Same material (rapid-absorption polyglactin 910), USP 2/0 gauge, colourless 75 cm thread; the needle geometry differs: W9933 mounts a 3/8 circle reverse cutting point Prime needle of 26 mm (PS), compared to the ½ circle cylindrical Taperpoint needle of 30 mm, and the configuration (1 thread versus 2 threads of the PGLAR format). Verified in authorised distributors and Ethicon EMEA catalogue. |
As homologous reference ranges in the sector, the braided rapid-absorption polyglactin 910 sutures of B. Braun (Safil Quick type line), DemeTECH (DemeCRYL Fast) and SMI (Surgicryl Fast Absorb) are listed, whose specific codes for the exact combination USP 2/0 / conical HR 30 mm needle / double thread 2×75 cm must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official data sheet the USP 2/0 gauge (metric 3), the ½ circle curvature, the type and size of needle (conical Taperpoint of 30 mm), the thread length (75 cm) and the colourless colour.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue and the gauge according to the anatomical area. USP 2/0 gauge with a 30 mm Taperpoint conical needle is a common choice for approximation of skin and mucous membranes, subcutaneous tissue, ligatures and ophthalmic surgery, with early loss of strength that in many indications avoids the need for suture removal. The double thread format (2 × 75 cm) provides two sterile strands per pack, optimising the yield per box.
Within the same PGLAR RAPID PRIME range with cylindrical conical-point needle, Cahnos offers complementary configurations: AMP2L22HR3020 (same Prime reference USP 2/0, HR 30 mm needle, individual format of 1 thread of 75 cm), AMP2L22HR4020.2 (Prime USP 2/0, HR 40 mm needle, double format 2×75 cm), AMP2L22HR3010.2 (Prime USP 0, HR 30 mm needle, double format 2×75 cm) and AMP2L22HR3030.2 (Prime USP 3/0, HR 30 mm needle, double format 2×75 cm). All references are supplied in a box of 12 units.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews