Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR of polyglactin 910 in RAPID version and Prime quality is the technical choice when the procedure requires short-term wound support, fully predictable reabsorption and excellent tissue handling. Its ½ circle 17 mm needle with atraumatic conical Ultra Plus point (HRP17) penetrates soft tissues with minimal resistance and less trauma, a quality especially valued in ophthalmic surgery, ligation of small-calibre vessels and approximation of superficial tissues. Presented in a box of 12 sterile units, it is a reliable and cost-effective alternative for operating theatres, day hospitals, ambulatory surgery and B2B supply contracts.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish that provides flexibility, smooth passage through tissues and a firm, secure knot. In its RAPID variant (lower molecular weight), absorption occurs by hydrolysis, i.e., by chemical degradation in contact with tissue fluids without depending on enzymes, within 40 to 45 days: it retains approximately 50% of its tensile strength at 5 days and loses it completely at 14 days. This short support window makes it ideal for tissues that heal quickly and where it is desired to minimise residual foreign material.
The ½ circle needle with cylindrical body and conical Ultra Plus point (reinforced taperpoint profile) ensures controlled passage even in slightly fibrous tissues, without aggressive cutting effect. The colourless thread facilitates its aesthetic use in superficial planes and in ophthalmology. Gamma radiation sterilisation guarantees final sterility with minimal alteration of the material’s mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet of the reference
| Material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight |
| Thread structure | Braided multifilament, grooved |
| Family / version | PGLAR – RAPID (rapid absorption), Prime quality (PREMISUT RAPID) |
| Gauge | USP 3/0 (metric 2) |
| Colour | Colourless |
| Thread length | 70 cm |
| Needle shape | ½ circle (1/2, 160°), cylindrical body |
| Needle tip | Conical atraumatic Ultra Plus (Taperpoint Ultra Plus), grooved |
| Needle size | 17 mm (HRP17) |
| Absorption | By hydrolysis, complete between 40 and 45 days |
| Residual tensile strength | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Manufacturer reference | P2L28HRP1730 (SKU AMP2L28HRP1730) |
| Commercial format | Box of 12 units |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days, by hydrolysis (predictable and uniform rate) |
The cited strength retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglactin 910 (PGLA line, 56–72 days), also available in our catalogue.
4. Equivalences and Cross-References
Rapid absorption polyglactin 910 is the most widespread category of absorbable multifilament suture in the surgical market. This reference shares material, USP 3/0 gauge, ½ circle curvature, 17 mm cylindrical needle, 70 cm colourless thread and rapid absorption profile with the homologous line of the main manufacturer in the sector. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue and in authorised distributors is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless), ½ circle RB-1 PLUS needle of 17 mm | V2150H (EMEA) | Comparable by category (not interchangeable 1:1) | They match in dimensions: material and rapid absorption (≈42 days), USP 3/0 gauge (metric 2), ½ circle 17 mm needle, 70 cm colourless braided thread. They differ: needle nomenclature and design (RB-1 PLUS vs. conical Ultra Plus HRP17 point), braid coating and packaging format (36 units in Ethicon vs. 12 units). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors. |
Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; they are not included in the table because no verified code is available for the exact combination USP 3/0 / 17 mm needle / conical Ultra Plus point / 70 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small-calibre vessels and ophthalmic surgery. The atraumatic conical Ultra Plus point needle is the most suitable for soft tissues and deep spaces, as it minimises tissue trauma at the entry point.
Within the same PGLAR RAPID Prime family with conical Ultra Plus point, Cahnos offers the version with 36 mm needle (HRP36) in USP 2/0 gauge with 90 cm thread (ref. AMP2L23HRP3620), as well as USP 0 and USP 1 gauges (refs. AMP2L23HRP3610 / AMP2L23HRP3601) to adjust the thread diameter while maintaining the same needle. If the protocol prefers classic trocar point (Tapercut), consult the HRT family (e.g. AMP2L28HRT2610 in USP 0 / 70 cm or AM2L23HRT3620 in USP 2/0 / 90 cm); if standard taperpoint conical point is preferred, consider the HR36 family (AM2L23HR3620). For firm tissues, the triangular reverse cutting alternative from the HS range. The colourless version offers maximum discretion in the field; if greater visibility is required, consult the same configuration in dyed thread on demand. Check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions or volume orders, contact the technical-commercial team of Cahnos.