Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID in Prime quality is the reference solution for B2B supply to operating theatres, general surgery departments, ophthalmic surgery, emergency departments and purchasing centres that require a synthetic absorbable thread with rapid absorption, exceptional handling and maximum knot security.
Its ½ circle needle with triangular reverse cutting point of 40 mm (HS40 profile) offers controlled penetration and a clean path through dense tissues, while the 90 cm colourless thread provides maximum discretion on the surgical field. A practical and cost-effective presentation, in a box of 12 units, for suturing tissues that heal quickly.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure, colourless and soft to the touch. In the RAPID variant, the thread is formulated to lose tensile strength in an accelerated and programmed manner: it retains 50% of initial strength at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days.
This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small and medium-calibre vessels and conjunctival suturing in ophthalmic surgery, where prolonged tensile support is not required. The reverse cutting needle creates a clean entry hole by directing the cut away from the wound, preserving the skin edge and preventing the cut from enlarging in the puncture bed. Sterile single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Material | Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide |
| Structure | Braided multifilament, undyed |
| Gauge | USP 0 (metric 3.5) |
| Thread diameter | 0.35 – 0.399 mm (indicative, according to Pharmacopoeia) |
| Thread colour | Colourless |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Needle tip | Triangular, reverse cutting |
| Needle size | HS 40 mm |
| Quality | Prime (PGLAR RAPID) |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Commercial format | Box of 12 units |
| SKU Cahnos | AMP2L23HS4010 |
| Factory reference | P2L23HS4010 (PGLAR family pattern; confirm with technical department) |
3.2. Absorption profile and tensile strength retention
| Parameter | Value |
| Absorption type | Hydrolysis |
| Absorption time | 40 – 45 days |
| Tensile strength at 5 days | 50% of initial strength |
| Tensile strength at 14 days | 0% (total loss of tensile support) |
| Absorption rate | Predictable and uniform |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 0 | 3.5 | 0.35 – 0.399 mm (indicative, according to Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market. This reference shares material, USP 0 gauge, ½ circle curvature, 40 mm needle, 90 cm colourless thread and absorption profile with the rapid-absorption line of the leading company in the sector:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE™ (polyglactin 910) | V9580H | Comparable by category (not interchangeable 1:1) | Same material, USP 0, 90 cm, colourless and 40 mm ½ circle needle; the needle is a CT Plus taper point instead of reverse cutting. Verified on official Ethicon EMEA website. |
Other homologous rapid-absorption lines in the sector, cited at family level without a code verified in public sources: Safil Quick™ / Novosyn Quick™ (B. Braun), DemeCRYL™ Fast (DemeTECH) and Surgicryl Fast Absorb (SMI). The comparison with any company is declared at category level, not interchangeable 1:1, as there is no official cross-reference table validated by the manufacturer for this exact configuration (USP 0, ½ circle reverse cutting needle of 40 mm, 90 cm colourless thread). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official datasheet the USP 0 gauge (metric 3.5), the ½ circle curvature, the needle type and size (reverse cutting 40 mm), the thread length (90 cm) and the colourless colour.
5. Selection tips and variants of interest
The USP 0 gauge (metric 3.5) is the most versatile for approximation of subcutaneous tissues, superficial fascia, ligation of small and medium-calibre vessels and conjunctival suturing, being the usual choice when good initial strength with rapid reabsorption is sought. The ½ circle reverse cutting needle of 40 mm is especially recommended for firm skin and mucosal tissues, where a clean passage without tearing the edge is required.
Within the same PGLAR RAPID range, Cahnos offers complementary configurations: the Normal quality version with identical configuration (SKU AM2L23HS4010), the variant with ½ circle taper point needle HR40 (SKU AMP2L23HR4010) for looser tissues, and the 3/8 circle reverse cutting needle DS30 (SKU AMP2L23DS3010) for smaller working fields. If the same absorption profile is required in rapid polyglycolic acid, please consult the PGAR RAPID family (e.g., SKU AMP223HS4010). The colourless version offers maximum aesthetic discretion; if greater visibility in the field is required, please enquire about the possibility of ordering the same configuration in violet on demand. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions or volume orders, contact the technical-commercial team at Cahnos.