Description
1. Product Presentation
The absorbable multifilament polyglactin 910 (PGLA/PGCL) suture without needle from the PREMISUT range is the trusted solution for operating theatres, ophthalmic clinics and B2B purchasing centres that need sterile surgical thread in loose format. Its presentation in 12 strands of 45 cm per unit maximises material utilisation in ligation techniques, soft tissue approximation and precision surgery, where a flexible thread with excellent handling and predictable clinical behaviour is valued. Manufactured to standard quality with a violet finish, it offers optimal visibility on the surgical field and mechanical performance comparable to the major braided absorbable ranges on the market, with an excellent quality-price ratio for volume procurement.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided, non-grooved multifilament structure provides great flexibility, smooth passage through tissues and firm, secure knot anchorage. Absorption occurs by hydrolysis, a uniform process independent of tissue enzymes, ensuring predictable mass loss between 56 and 72 days, with minimal tissue reaction and maintenance of tensile strength during the first weeks of healing (approximately 32-35 days). As a needle-free presentation, the thread is ready for mounting on reusable needle holders and manual suturing techniques, being especially practical for ligatures, internal closures and precision procedures. USP 1 gauge (metric 4) combines a medium-thick diameter (0.40 – 0.499 mm) with notable tension retention in tissues under moderate load. It is supplied sterile by ethylene oxide, for single-use and not for re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Material / composition | Polyglactin 910 (PGLA/PGCL), copolymer 90% glycolide / 10% L-lactide |
| Suture type | Synthetic absorbable multifilament |
| Structure | Braided multifilament, non-ribbed |
| Format | Without needle (loose thread for ligatures and manual suturing) |
| USP size | 1 (metric 4) |
| Approximate diameter | 0.40 – 0.499 mm (USP/EP standard) |
| Thread length | 12 strands of 45 cm per unit (12 × 45 cm) |
| Colour | Violet (colourless on request) |
| Sterilisation | Ethylene oxide (EtO) |
| Tissue reaction | Minimal |
| Brand / quality | PREMISUT, standard quality |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 10 boxes |
| Reference / SKU | 1L1-12.4501 |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
3.3. Absorption profile
| Parameter | Value |
| Absorption type | Hydrolysis |
| Estimated duration | 56 – 72 days |
| Tensile strength retention | Approx. 32 – 35 days |
| Tissue reaction | Minimal |
| Knot tying | Excellent safety |
3.4. Gauge equivalence
| USP size | Approximate diameter | Metric |
| 1 | 0.40 – 0.499 mm | 4 |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice. This needle-free reference behaves as a functional equivalent of the braided polyglactin 910 threads from the main international manufacturers, with an absorption profile (56 – 72 days) and tensile strength retention equivalent to ranges such as Vicryl / Vicryl Plus (Ethicon, Johnson & Johnson), Safil (B. Braun) and Polysorb (Medtronic). As for loose strands without needle, it is comparable to the polyglactin 910 range from Laboratorio Aragó (presentation in boxes of 12 units). Within the Cahnos catalogue, the warehouse version of this same presentation corresponds to reference AM1L1-12.4501. This reference is complemented by the rest of the PGLA family of loose thread without needle in other gauges and formats: 1L1-12.4502 (USP 2, 12 × 45 cm), 1L1-6.4501 (USP 1, 6 × 45 cm), 1L1-6.4502 (USP 2, 6 × 45 cm), 1L1-3.4501 (USP 1, 3 × 45 cm) and 1L1-5.7001 (USP 1, 5 × 70 cm). For sutures mounted with needle of the same material, the 1L18HRT4810 (1/2 cylindrical, gauge 0, violet, 70 cm) and P1L18HRP1360 (Prime 1/2 cylindrical, 6/0, violet, 70 cm) stand out, allowing supplier and technical criteria to be unified between loose thread and mounted sutures.
5. Selection tips and variants of interest
The needle-free format is the recommended option for ligatures, approximation sutures with reusable needle holder and procedures where the thread needs to be cut to the technique’s requirements. USP 1 gauge (metric 4) is indicated for tissues requiring notable initial resistance: deep planes, fascia, aponeurosis, moderate tension closures and vascular ligatures, while maintaining excellent handling for general surgery and precision approaches. The presentation in 12 strands of 45 cm per unit maximises yield per box and reduces waste in the operating theatre. The violet colour facilitates visibility and control of the thread on the surgical field; the colourless version is available on request for maximum aesthetic discretion. For earlier absorption, the rapid-absorption polyglactin 910 range (Rapid) may be considered, and for longer tensile support, the PGCL caprolactone or polydioxanone lines. Presentation in a box of 12 units with a minimum order of 10 boxes, ideal for scheduled replenishment of operating theatre material under B2B conditions. Consult our technical-commercial team at Cahnos to optimise your order by boxes and benefit from special conditions.





Reviews
There are no reviews yet.