Description
1. Product Presentation
The absorbable multifilament Polyglactin 910 (PGLA/PGCL) suture without needle from the PREMISUT range is the reference solution for operating theatres, ophthalmic clinics and B2B purchasing centres that need sterile surgical thread in loose format, ready to mount on a needle holder or use in manual ligature techniques. Its presentation in 2 threads of 70 cm per unit guarantees optimal use of the material in tissue approximation procedures, vascular ligatures and precision surgery, where a flexible, resistant thread with predictable clinical behaviour is valued. Manufactured in standard quality with a violet finish, it offers excellent visibility on the surgical field and mechanical performance comparable to the major braided absorbable ranges on the market, with an excellent quality-price ratio for volume B2B procurement.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide (PGLA/PGCL). Its braided, non-grooved multifilament structure provides great flexibility, smooth passage through tissues and firm, secure knot anchorage. Absorption occurs by hydrolysis, a uniform process independent of tissue enzymes that guarantees predictable mass loss between 56 and 72 days, with minimal tissue reaction and maintenance of tensile strength during the first weeks of healing. As it is a needle-free presentation, the thread is ready for mounting on reusable needle holders and manual suture techniques, being especially practical for ligatures, internal closures and precision procedures. The USP 2 (metric 5) gauge has an approximate diameter of 0.50 – 0.599 mm, indicated for tissues that support high tension: aponeurosis, fascia, deep muscle planes and abdominal wall closures. It is supplied sterile by ethylene oxide (EtO), for single use and without re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Material / composition | Polyglactin 910 (PGLA/PGCL), copolymer 90% glycolide / 10% L-lactide |
| Suture type | Synthetic absorbable multifilament |
| Structure | Braided multifilament, non-ribbed |
| Format | Without needle (loose thread for manual suturing and ligatures) |
| USP size | 2 (metric 5) |
| Approximate diameter | 0.50 – 0.599 mm (USP/EP standard) |
| Thread length | 2 threads of 70 cm per unit (2 × 70 cm) |
| Colour | Violet (colourless on request) |
| Sterilisation | Ethylene oxide (EtO) |
| Tissue reaction | Minimal |
| Brand / quality | PREMISUT, standard quality |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference / SKU | 1L1-2.7002 |
3.2. Tensile strength retention profile
| Period | Strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
3.3. Absorption profile
| Parameter | Value |
| Absorption type | Hydrolysis |
| Estimated duration | 56 – 72 days |
| Tensile strength retention | Approx. 32 – 35 days |
| Tissue reaction | Minimal |
| Knot tying | Excellent safety |
3.4. Gauge equivalence
| USP size | Approximate diameter | Metric size |
| 2 | 0.50 – 0.599 mm | 5 |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice. This needle-free reference behaves as a functional equivalent of the braided polyglactin 910 threads from the main international manufacturers, with an absorption profile (56 – 72 days) and tensile strength retention equivalent to ranges such as Vicryl / Vicryl Plus (Ethicon, Johnson & Johnson), Safil (B. Braun) and Polysorb (Medtronic). As for loose strands without needle, it is comparable to the polyglactin 910 range from Laboratorio Aragó. Within the Cahnos catalogue, the warehouse version of this same presentation corresponds to reference AM1L1-2.7002. This reference is complemented by the rest of the PGLA family of loose thread without needle in the same USP 2 gauge: 1L1-5.7002 (5 × 70 cm), 1L1-3.5002 (3 × 50 cm) and 1L1-6.4502 (6 × 45 cm), as well as other gauges in 6 × 45 cm format (1L1-6.4510 USP 0, 1L1-6.4520 USP 2/0, 1L1-6.4530 USP 3/0, 1L1-6.4540 USP 4/0 and 1L1-6.4550 USP 5/0). For sutures mounted with needle of the same material, the 1L18HRT4810 (1/2 cylindrical, gauge 0, violet, 70 cm) and P1L18HRP1360 (Prime 1/2 cylindrical, 6/0, violet, 70 cm) stand out, allowing supplier and technical criteria to be unified between loose thread and mounted sutures.
5. Selection tips and variants of interest
The needle-free format is the recommended option for ligatures, approximation sutures with reusable needle holder and procedures where the thread needs to be cut to the technique. The USP 2 (metric 5) gauge is indicated for tissues with high tension: aponeurosis, fascia, muscle planes, abdominal wall closures and ligatures of medium-calibre vessels, offering an excellent balance between thick diameter and initial resistance. The presentation in 2 threads of 70 cm per unit offers long, comfortable strands for wide surgical fields, maximising yield per box and reducing waste. The violet colour facilitates visibility and control of the thread on the surgical field; the colourless version is available on demand for maximum aesthetic discretion. For earlier absorption, the rapid absorption polyglactin 910 range (Rapid) can be considered and, for longer tensile support, the PGCL caprolactone or polydioxanone lines. Presentation in a box of 12 units with a minimum order of 30 boxes, ideal for scheduled replenishment of operating theatre material under B2B conditions. Consult our technical-commercial team at Cahnos to optimise your order by boxes and benefit from special conditions.





Reviews
There are no reviews yet.