We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PREMISUT PGLA (Polyglactin 910) | 3/8 Circle Reverse Cutting Triangular Point Needle DS16 (16 mm) | USP 5/0 Undyed | Suture 75 cm | Box of 12 units (Ref. 1L22DS1650)

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable suture PREMISUT of Polyglactin 910 (PGLA), undyed, braided, grooved multifilament, with a ⅜ (3/8) circle reverse cutting triangular point needle, 16 mm (DS16). USP size 5/0 (metric 1), suture length 75 cm, with predictable absorption by hydrolysis between 56 and 72 days and tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Sterile by ethylene oxide, single-use, with minimal tissue reaction and indicated for tissue approximation, ligation and ophthalmic surgery. Presentation in a box of 12 units, minimum order of 30 boxes. Ref. 1L22DS1650.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L22DS1650

Description

1. Commercial Introduction

The absorbable suture PREMISUT of Polyglactin 910 (PGLA), reference 1L22DS1650, is the technical reference solution for B2B supply to operating theatres, ophthalmology clinics, purchasing centres and healthcare distributors. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and great knot security in tissue approximation, ligatures and ophthalmic surgery.

Its ⅜ circle needle with a 16 mm (DS16) reverse cutting triangular point ensures firm, controlled penetration even in non-compliant tissues, while the fluted braided thread in colourless offers total aesthetic discretion on the surgical field, smooth glide and reliable knot tying. It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for the continuous supply of your healthcare centre.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted (coated) finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knotting, even in fine gauges such as USP 5/0 (metric 1).

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, fibrous tissues with controlled trauma, avoiding tears; it is therefore particularly indicated in ophthalmic surgery (sclera), skin and mucous membranes. The colourless colour ensures optimal aesthetic integration. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference 1L22DS1650

Parameter Specification
Brand / Range PREMISUT
Reference (SKU) 1L22DS1650
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 5/0 (metric 1)
Thread colour Colourless
Thread length 75 cm
Needle shape ⅜ (3/8) circle
Tip type Reverse-cutting triangular (inverted triangle / reverse cut)
Needle size DS16 (16 mm)
Quality Normal (standard range)
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (EtO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56 – 72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

3.3. Size equivalence

USP size Metric size Approximate diameter
5/0 1 0.10 – 0.149 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used medium-duration absorbable multifilament in the surgical market. This PREMISUT suture is equivalent in composition and clinical behaviour to the main commercial ranges of polyglactin 910, maintaining the same absorption profile (56-72 days) and tensile strength retention:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ⅜ circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent with the same configuration (triangular DS16 mm needle, USP 5/0 gauge and 75 cm) in violet is reference 1L12DS1650, and the premium Prime version of this same presentation in colourless corresponds to reference P1L22DS1650. The indicated equivalences are for guidance only; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue and the gauge needed according to the anatomical area. USP 5/0 (metric 1) is indicated for delicate tissues: thin skin, mucous membranes, subcutaneous tissue and ophthalmic surgery. The reverse cutting triangular point needle is recommended when firm tissues need to be penetrated without tearing them (skin, fascia, aponeurosis, sclera). The colourless colour is especially valued in aesthetic and reconstructive surgery for its discretion.

Reference Variant
1L22DS1650 PGLA, DS16 mm needle, USP 5/0, colourless, 75 cm (current product)
1L12DS1650 PGLA, DS16 mm needle, USP 5/0, violet, 75 cm (maximum visibility in the field)
P1L22DS1650 PGLA Prime, DS16 mm needle, USP 5/0, colourless, 75 cm (superior quality)
P1L12DS1650 PGLA Prime, DS16 mm needle, USP 5/0, violet, 75 cm (superior quality and high visibility)
1L22DS1640 PGLA, DS16 mm needle, USP 4/0, colourless, 75 cm (finer gauge)
1L22DS1930 PGLA, DS19 mm needle, USP 3/0, colourless, 75 cm (larger gauge and needle)
AMP122DS1650 PGA, DS16 mm needle, USP 5/0, colourless, 75 cm (absorption from 60 to 90 days)

All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to guarantee the continuous supply of your healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLA), copolymer of 90% glycolide and 10% L-lactide

Thread structure

Multifilament braided fluted

USP size

5/0 (metric 1)

Needle

⅜ (3/8) circle with reverse cutting triangular point

Needle size

DS16 (16 mm)

Sterilisation

Ethylene oxide (EtO), single-use, not re-sterilisable

Quality

Normal (standard)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DS 16

Usp

5/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PREMISUT PGLA (Polyglactin 910) | 3/8 Circle Reverse Cutting Triangular Point Needle DS16 (16 mm) | USP 5/0 Undyed | Suture 75 cm | Box of 12 units (Ref. 1L22DS1650)”

Your email address will not be published. Required fields are marked *