We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime PREMISUT – 3/8 Circle Needle Triangular Reverse Cutting Point DS19 (19 mm), USP 3/0, Undyed, 75 cm, Ref. P1L22DS1930, Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) in Prime quality from the PREMISUT range, with a ⅜ circle needle with triangular reverse cutting point of 19 mm (DS19). Braided grooved thread in USP 3/0 gauge, undyed colour for maximum discretion, with a length of 75 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 weeks and 30 % at 4 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L22DS1930, price per box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L22DS1930

Description

1. Commercial Introduction

The absorbable suture PREMISUT Prime made of Polyglactin 910 (PGLA), reference P1L22DS1930, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, purchasing centres and healthcare distributors. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and great knot security in tissue approximation, ligatures and ophthalmic surgery.

Its ⅜ circle needle with a reverse cutting triangular point of 19 mm ensures firm and controlled penetration even in non-compliant tissues, while the braided grooved thread in undyed colour offers total aesthetic discretion on the surgical field, smooth sliding and reliable knot tying. It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for the continuous supply of your healthcare centre.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved (coated) finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 3/0 (metric 2).

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance.

The ⅜ circle needle with a reverse cutting triangular point penetrates firm and fibrous tissues with controlled trauma, avoiding tears, which is why it is especially indicated in ophthalmic surgery (sclera), skin and mucous membranes. The undyed colour of the thread guarantees optimal aesthetic integration. The product is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference P1L22DS1930

Parameter Specification
Brand / Range PREMISUT (Prime quality, premium range)
Reference (SKU) P1L22DS1930
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 3/0 (metric 2)
Thread colour Colourless
Thread length 75 cm
Needle shape 3/8 circle
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS19 (19 mm) Prime
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56 – 72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 2 0.20 – 0.249 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT Prime suture is equivalent in composition and clinical behaviour to the main commercial ranges of polyglactin 910, maintaining the same absorption profile of 56-72 days and tensile strength retention:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Laboratory Aragó Range of polyglactin 910 with 3/8 circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent with the same configuration (triangular needle DS19 mm, USP 3/0 gauge) in violet colour is reference P1L12DS1930; the variant in 4/0 undyed gauge is P1L22DS1940. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue and the necessary gauge according to the anatomical area. The USP 3/0 (metric 2) gauge offers an ideal balance between initial strength and handling for soft tissues, subcutaneous planes, ligatures and microsurgery. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing them (skin, fascia, aponeurosis, sclera).

Reference Variant
P1L22DS1930 PGLA Prime, DS19 mm needle, USP 3/0, undyed thread, 1 × 75 cm (current product)
P1L12DS1930 PGLA Prime, DS19 mm needle, USP 3/0, violet thread, 1 × 75 cm
P1L22DS1940 PGLA Prime, DS19 mm needle, USP 4/0, undyed thread, 1 × 75 cm (smaller gauge)
P1L12DS2430 PGLA Prime, DS24 mm needle, USP 3/0, violet, 1 × 75 cm (larger needle)
P1L12DS3030 PGLA Prime, DS30 mm needle, USP 3/0, violet, 1 × 75 cm
P1L12RDS1930.2 PGLA Prime, DS19 mm needle, USP 3/0, violet, 2 × 75 cm (double strand)
AMP122DS1930 PGA, DS19 mm needle, USP 3/0, undyed (absorption of 60 to 90 days)

The undyed colour is especially valued in aesthetic and reconstructive surgery procedures for its discretion. All references are supplied in boxes of 12 units. As it is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.

Additional information

Reference

P1L22DS1930

Brand

PREMISUT

Material

Polyglactin 910 (PGLA)

Thread structure

Multifilament braided fluted

USP size

3/0 (metric 2)

Tip type

Triangular with reverse cutting

Needle size

DS19 (19 mm)

Absorption mechanism

By hydrolysis, 56-72 days

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DS 19

Usp

3/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime PREMISUT – 3/8 Circle Needle Triangular Reverse Cutting Point DS19 (19 mm), USP 3/0, Undyed, 75 cm, Ref. P1L22DS1930, Box of 12 units”

Your email address will not be published. Required fields are marked *