Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT made of Polyglactin 910 (PGLA), reference 1L12DS2410, is the trusted solution for professionals seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security for tissue approximation, ligatures and ophthalmic surgery. Its ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24) ensures firm, controlled penetration through tissues of a certain consistency, while the 75 cm braided grooved violet thread offers optimal visibility on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for B2B supply to operating theatres, ophthalmic clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units with a minimum order of 30 boxes, designed for institutional stock management.
2. Technical explanation
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in sizes such as USP 0.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with a 24 mm reverse cutting triangular point (inverted triangle) penetrates firm, dense tissues with controlled trauma, avoiding tearing. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide, is single-use and is not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference 1L12DS2410
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (standard quality) |
| Reference (SKU) | 1L12DS2410 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet (also available colourless in the range) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS 24 (24 mm) |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 30 % of the initial strength |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable and controlled absorption rate. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 (PGLA) is the most widely used medium-duration absorbable multifilament in the surgical market. This PREMISUT suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of braided polyglactin 910:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (triangular needle DS 24 mm, USP 0 gauge, 75 cm violet thread) in Prime quality is reference P1L12DS2410, ideal when seeking the top range. If a longer absorption profile is preferred (60-90 days), in the polyglycolic acid (PGA) family reference AM112DS2410 stands out, with the same DS 24 mm needle geometry. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and ophthalmic surgery procedures. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis, sclera).
| Reference | Variant |
|---|---|
| 1L12DS2410 | Standard PGLA USP 0, ⅜ triangular needle DS 24 mm, violet, 75 cm (current product) |
| P1L12DS2410 | Prime PGLA USP 0, same DS 24 mm configuration, violet, 75 cm (top range) |
| 1L12DS2420 | Standard PGLA USP 2/0, DS 24 mm needle, violet, 75 cm (larger gauge) |
| 1L12DS2430 | Standard PGLA USP 3/0, DS 24 mm needle, violet, 75 cm (finer gauge) |
| 1L12DS2630 | Standard PGLA USP 3/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (longer needle) |
| 1L12DS4010 | Standard PGLA USP 0, ⅜ triangular needle DS 40 mm, violet, 75 cm (largest needle) |
| AM112DS2410 | PGA USP 0, DS 24 mm needle, violet, 75 cm (absorption from 60 to 90 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. As it is a sterile single-use product, always check the integrity of the packaging before each procedure and respect the expiry date. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.