Absorbable Multifilament PGLA Suture (Polyglactin 910) PREMISUT Prime – 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm), USP 5/0 Colourless, 45 cm, Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture PREMISUT Prime of Polyglactin 910 (PGLA) with a ⅜ circle needle, 19 mm (DS19) reverse cutting triangular point, USP 5/0 gauge (metric 1) and 45 cm colourless fluted thread. Predictable absorption by hydrolysis between 56 and 72 days, with retention of 75% of tensile strength at 2 weeks, 50% at 3 and 30% at 4 weeks. Sterilised by ethylene oxide, it offers minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery, supplied in a box of 12 units with stock for wholesale distribution. Ref. P1L21DS1950.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L21DS1950

Description

1. About this suture

The Absorbable Multifilament Suture PREMISUT Prime of Polyglactin 910 (PGLA), reference P1L21DS1950, is the benchmark professional solution for B2B supply to operating theatres, ophthalmic clinics, purchasing groups and healthcare distributors. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and excellent knot security in tissue approximation, ligatures and ophthalmic surgery.

Its ⅜ circle needle with a 19 mm (DS19) reverse cutting triangular point ensures firm, controlled penetration even in non-compliant tissues, while the 45 cm colourless fluted thread offers excellent aesthetic discretion and smooth glide over the surgical field. It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money.

2. Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 5/0 (metric 1, approximate diameter 0.10 to 0.149 mm).

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, fibrous tissues with controlled trauma, avoiding tearing, which is why it is particularly indicated in ophthalmic surgery (sclera), skin and mucous membranes. The colourless colour minimises suture visibility, an advantage appreciated in ophthalmic and aesthetic procedures. The product is supplied sterile by ethylene oxide (EtO), single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L21DS1950

Parameter Specification
Brand / Range PREMISUT (Prime quality)
Reference (SKU) P1L21DS1950
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 5/0 (metric 1)
Thread colour Colourless fluted
Thread length 45 cm
Needle shape 3/8 circle
Tip type Triangular with reverse cutting (inverted triangular point)
Needle size DS19 (19 mm) Prime
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (EtO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units

3.2. Tensile strength retention and absorption profile

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56 – 72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

3.3. Size equivalence

USP size Metric size Approximate diameter
5/0 1 0.10 – 0.149 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used medium-term absorbable multifilament in the surgical market. This PREMISUT Prime suture is equivalent in composition and clinical behaviour to the main commercial ranges of polyglactin 910, maintaining the same absorption profile of 56-72 days and tensile strength retention:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Laboratory Aragó Range of polyglactin 910 with 3/8 circle needles (DS series)

Within the Cahnos catalogue, the same presentation in USP 5/0 gauge with DS19 mm needle is available in a 45 cm violet strand under reference P1L11DS1950 and in a 75 cm violet strand under reference P1L12DS1950. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

The USP 5/0 gauge (metric 1) is indicated for delicate tissues, fine skin, mucous membranes and ophthalmic surgery, where a small-diameter thread with good initial strength is required. The ⅜ circle needle with reverse cutting triangular point is especially recommended for firm or difficult-to-penetrate tissues, where control and high puncture capacity without tearing are required.

Reference Variant
P1L21DS1950 PGLA Prime, DS19 mm needle, USP 5/0, colourless, 45 cm (current product)
P1L11DS1950 PGLA Prime, DS19 mm needle, USP 5/0, violet, 45 cm
P1L12DS1950 PGLA Prime, DS19 mm needle, USP 5/0, violet, 75 cm
P1L21XDS1950 PGLA Prime, XDS19 precision needle, USP 5/0, colourless, 45 cm (square body)
P1L21DS1940FN PGLA Prime, fine DS19 needle, USP 4/0, colourless, 45 cm (smaller gauge)
AMP121DS1950 PGA Prime, DS19 mm needle, USP 5/0, colourless, 45 cm (polyglycolic acid)

For maximum visibility in the field, choose the fluted violet version; if you prefer greater aesthetic discretion, this colourless version is the most suitable. If the protocol requires longer tensile support, consider the absorbable polydioxanone monofilament lines; if you are looking for faster absorption, consult the rapid absorption range of the same family. All references are supplied in boxes of 12 units. Contact our technical-commercial team to optimise your order by box and take advantage of special B2B conditions.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Multifilament braided fluted

Brand

PREMISUT

Thread colour

Colourless fluted

USP size

5/0 (metric 1)

Thread diameter

0.10 – 0.149 mm

Metric gauge (EP)

1

Needle type

Reverse cutting triangular point

Needle size

DS19 (19 mm) Prime

Sterilisation

Ethylene oxide (EtO)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Use

Single-use, not re-sterilisable

Reference

P1L21DS1950

Medida de aguja

DS 19

Usp

5/0

Color

Colourless

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)