Description
1. Product Presentation
The Absorbable Multifilament PGLA Polyglactin 910 Suture, reference 1L22DS3020, from the PREMISUT range in standard quality, is the trusted choice for the professional seeking a synthetic absorbable surgical thread with predictable behaviour, excellent handling and maximum knot security. Its ⅜ circle needle with 30 mm reverse cutting triangular point (DS 30) offers firm, controlled penetration, ideal for tissues of a certain consistency, while the 75 cm colourless braided thread ensures a clean aesthetic, minimal visual interference on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable, sterile, single-use medical device with an excellent quality-price ratio for B2B procurement for operating theatres, ophthalmic clinics, purchasing groups and distributors of surgical material. Commercial presentation in a box of 12 units, designed for institutional stock management.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying in fine gauges such as USP 2/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes the suture suitable for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ⅜ circle needle with 30 mm reverse cutting triangular point (inverted triangular) penetrates firm, fibrous tissues with controlled trauma, avoiding tearing; it is especially useful in ophthalmic surgery (sclera), skin and mucous membranes. The product is supplied sterile by ethylene oxide, is single-use and is not resterilisable.
3. Technical Specifications
3.1. General characteristics of reference 1L22DS3020
| Brand / Range | PREMISUT (standard quality) |
| Reference (SKU) | 1L22DS3020 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless (also available in violet in the range) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS 30 (30 mm) |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size |
| 2/0 | 3 |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT suture is equivalent in composition and behaviour to the main commercial ranges of polyglactin 910:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (DS 30 mm triangular needle, USP 2/0 gauge, 75 cm thread) in violet is reference 1L12DS3020, and in the higher range (Prime quality) reference P1L22DS3020. If a longer absorption profile is preferred (60-90 days), in the polyglycolic acid (PGA) family reference AM122DS3020 stands out; and if faster absorption is needed (40-45 days), the PGLAR Rapid family offers reference AM2L22DS3020, all with the same DS 30 mm needle geometry.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the gauge needed according to the anatomical area. USP 2/0 gauge (metric 3) offers an ideal balance between initial strength and handling for fine tissues, ligatures and ophthalmic surgery. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis, sclera).
| Reference | Variant |
| 1L22DS3020 | PGLA USP 2/0, ⅜ triangular needle DS 30 mm, colourless, 75 cm (current product) |
| 1L12DS3020 | PGLA USP 2/0, same DS 30 mm needle, violet colour |
| 1L12DS3030 | PGLA USP 3/0, same DS 30 mm needle (finer gauge for microsurgery) |
| 1L12DS3010 | PGLA USP 0, same DS 30 mm needle (greater initial strength) |
| 1L22DS2420 | PGLA USP 2/0, DS 24 mm needle (shorter needle) |
| 1L12DS3620 | PGLA USP 2/0, DS 36 mm needle (longer needle) |
| P1L22DS3020 | PGLA Prime USP 2/0, same DS 30 mm configuration, colourless (higher range) |
| AM122DS3020 | PGA USP 2/0, DS 30 mm needle (absorption from 60 to 90 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours under order, contact our technical-commercial team at Cahnos.





Reviews
There are no reviews yet.