Description
1. Product Presentation
The Absorbable Multifilament PGLA Polyglactin 910 Suture reference 1L28DS3010, from the PREMISUT range in standard quality, is the trusted choice for the professional seeking a synthetic absorbable suture with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and ophthalmic surgery.
Its 3/8 circle needle with reverse cutting triangular point of 30 mm (DS 30) offers a firm and controlled penetration, ideal for tissues of certain consistency such as the sclera, skin or mucosa, while the colourless braided thread of 75 cm guarantees a clean aesthetic, minimal visual interference on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money for B2B supply of operating theatres, ophthalmic clinics, purchasing centres and surgical material distributors. Commercial presentation in a box of 12 units, designed for institutional stock management.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in medium gauges such as USP 0.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue regains its own resistance.
The 3/8 circle needle with reverse cutting triangular point (inverted triangular) of 30 mm penetrates firm and fibrous tissues with controlled trauma, avoiding tears; it is especially useful in ophthalmic surgery (sclera), skin and mucosae. The product is supplied sterile by ethylene oxide, is single-use and is not re-sterilisable.
3. Technical Specifications
3.1. General characteristics of reference 1L28DS3010
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (standard quality) |
| Reference (SKU) | 1L28DS3010 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Undyed (also available violet in the range) |
| Thread length | 75 cm |
| Needle shape | 3/8 circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS 30 (30 mm) |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 is the most widespread medium-duration absorbable multifilament on the surgical market. This PREMISUT suture is equivalent in composition and behaviour to the main commercial ranges of polyglactin 910:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Laboratory Aragó | Range of polyglactin 910 with 3/8 circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (triangular needle DS 30 mm, gauge USP 0, 75 cm thread) in violet colour is reference 1L12DS3010, and in the higher range (Prime quality) reference P1L28DS3010. If a longer absorption profile is preferred (60-90 days), in the polyglycolic acid (PGA) family the reference AM112DS3010 stands out, with identical DS 30 mm needle geometry.
5. Selection tips and variants of interest
To choose the most suitable suture, evaluate the wound support time required by the tissue and the necessary gauge according to the anatomical area. Gauge USP 0 (metric 3.5) offers an ideal balance between initial resistance and handling for soft tissues, ligatures and microsurgery. The reverse cutting triangular point needle is indicated when it is necessary to penetrate firm tissues without tearing (skin, fascia, aponeurosis, sclera).
| Reference | Variant |
|---|---|
| 1L28DS3010 | PGLA USP 0, 3/8 triangular needle DS 30 mm, colourless, 75 cm (current product) |
| 1L12DS3010 | PGLA USP 0, same needle DS 30 mm, violet colour |
| P1L28DS3010 | PGLA Prime USP 0, same configuration DS 30 mm, colourless (higher range) |
| 1L22DS3020 | PGLA USP 2/0, same needle DS 30 mm, colourless (finer gauge) |
| 1L12DS3030 | PGLA USP 3/0, same DS 30 mm needle (fine calibre for microsurgery) |
| 1L12DS4010 | PGLA USP 0, triangular needle DS 40 mm (longer needle) |
| AM112DS3010 | PGA USP 0, DS 30 mm needle (absorption from 60 to 90 days) |
The colourless thread is recommended when minimal visual interference and an aesthetic finish are sought, especially in visible areas or ophthalmic procedures; if greater visibility on the surgical field is preferred, request the violet version. All references are supplied in a box of 12 units. For special B2B conditions, volume orders or enquiry about additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.





Reviews