We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Silk Suture PREMISUT Prime 1/2 Circle Taper Point HR13 (13 mm) · USP 6/0 (EP 0.7) · Black Braided Thread 45 cm · Non-Absorbable · Box of 12 units (Ref. P541HR1360)

Original price was: 29,90 €.Current price is: 21,40 €.

Non-absorbable suture of 100 % natural braided silk in quality PREMISUT Prime: black non-grooved strand of 45 cm in USP 6/0 gauge (metric EP 0.7), mounted on a 1/2 circle needle with cylindrical body and Taperpoint conical point of 13 mm (HR13 profile). Wax and silicone coating that reduces capillarity, facilitates sliding and ensures a very secure knot (technique 2 = 1 = 1 = 1), with wound support for more than three months through gradual encapsulation. Indicated for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Sterilised by ethylene oxide, single-use and not re-sterilisable; B2B presentation in a box of 12 individual sterile pouches with batch traceability and minimum order of 30 boxes. Manufacturer ref. P541HR1360 · SKU Cahnos AMP541HR1360.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP541HR1360

Description

The Silk Suture PREMISUT Prime HR13 is the reference in the premium range of non-absorbable silk from Cahnos for the professional who demands a natural-origin thread with exceptional handling, reliable knotting and predictable clinical behaviour. It combines a 100% natural braided silk strand in black, coated with wax and silicone, in USP 6/0 gauge and 45 cm of thread, mounted on a ½ circle needle with cylindrical body and conical Taperpoint point of 13 mm (HR13 profile). The Prime quality provides precision sharpening, non-ribbed finish, batch-to-batch consistency and full traceability, being the usual choice in ophthalmology departments, skin surgery, microsurgery and B2B purchasing and tendering centres.

Technical explanation of the material and procedure

Surgical silk is a natural protein fibre (fibroin from the cocoon of Bombyx mori) processed to remove natural waxes and gums and presented in a braided multifilament construction, coated with a mixture of wax and silicone. This coating reduces capillarity and friction when passing through tissue, improves handling and favours knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HR13 needle of 13 mm features a ½ circle curvature with cylindrical body and conical point (Taperpoint): the point separates the fibres without cutting them, achieving atraumatic penetration and minimal trauma to the puncture bed, making it especially suitable for soft, lax, well-vascularised or delicate tissues. The USP 6/0 gauge (metric EP 0.7) is one of the finest in the range, ideal for very delicate planes in ophthalmology and skin surgery, and the black colour ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable. Compliant with USP/EP Pharmacopoeia and with CE marking (MDR).

Technical specifications

Data verified according to the technical data sheet and instructions for use of the PREMISUT Prime range.

General characteristics

Parameter Specification
Brand / Quality PREMISUT Prime (premium range)
Factory reference P541HR1360
SKU Cahnos AMP541HR1360
Thread material 100% natural silk (Bombyx mori fibroin), braided multifilament
Thread structure Braided (multifilament), non-grooved surface (Prime)
Coating Wax and silicone (anti-capillarity, low tissue drag)
Absorption type Non-absorbable; gradual encapsulation, support for more than 3 months
Gauge / USP size USP 6/0 (metric EP 0.7)
Approximate thread diameter 0.070 – 0.099 mm (USP Pharmacopoeia, non-absorbable suture)
Thread length 45 cm (single strand)
Thread colour Black non-ribbed (high visibility)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Taperpoint conical (non-cutting)
Needle size HR13 (13 mm)
Swaged 1 needle / 1 thread of 45 cm per unit
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Commercial presentation Box of 12 units (individual sterile sachets); minimum order 30 boxes
Indications Soft tissue approximation, ligatures, ophthalmology, microsurgery and skin surgery
Regulatory standard Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Gauge equivalence according to USP/EP Pharmacopoeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
6/0 (this product) 0.7 0.070 – 0.099 mm
5/0 1.0 0.10 – 0.149 mm
4/0 1.5 0.15 – 0.199 mm

Family PREMISUT Prime – Silk, ½ circle needle, cylindrical body conical point (HR profile), USP 6/0

Needle profile USP size Colour Thread (cm) References
HR12 Prime (taper point, 12 mm) 6/0 Black 45 P541HR1260 / AMP541HR1260
HR13 Prime (conical point, 13 mm) · this product 6/0 Black 45 P541HR1360 / AMP541HR1360
HR13 standard ribbed (conical point, 13 mm) 6/0 Black 45 541HR1360 / AM541HR1360
HR16 Prime (taper point, 16 mm) 6/0 Black 45 P541HR1660 / AMP541HR1660

Equivalences and cross-references

The reference P541HR1360 corresponds to the official nomenclature of the PREMISUT Prime range (P = Prime quality; 541 = black 45 cm thread; HR = ½ circle needle with cylindrical body and conical point; 13 = 13 mm; 60 = USP 6/0 gauge) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. This needle geometry (HR13, conical point, USP 6/0, black 45 cm strand) is only safely interchangeable within the PREMISUT system itself.

There is no manufacturer-validated equivalence table that cross-references this specific configuration (black braided silk, ½ circle conical-point HR13 needle of 13 mm, USP 6/0 gauge and 45 cm strand) with codes from other commercial houses; consult the technical department of Cahnos before use in tendering or direct substitution. Non-absorbable black braided silk is one of the most standardised natural suture families on the market, with homologous lines of ½ circle and conical-point needles that must be reviewed property by property (material, USP/metric gauge, curvature, conical-point family, needle size and length —tolerance ±1 mm for needles ≥ 10 mm—, thread length, colour, coating and CE/MDR regulatory classification) before any substitution: B. Braun/Aesculap SILKAM®, Ethicon (J&J MedTech) MERSILK® / PERMA-HAND™ Silk, Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Assusilk®, Laboratorio Aragó, Lorca Marín, Unilene and Serag-Wiessner, among others. Always verify reference by reference and confirm each manufacturer’s IFU before use in a surgical protocol.

Selection tips and variants of interest

Tissue to suture: the USP 6/0 gauge (metric EP 0.7) is the microsurgery choice for very delicate planes —fine facial skin, eyelids, mucous membranes, ophthalmology and low-tension soft tissues— where the fine diameter minimises tissue reaction. The HR13 conical-point needle separates the fibres without cutting them, making it especially suitable in lax and well-vascularised tissues where minimal puncture trauma is sought; for firm and poorly distensible tissues, consider reverse-cutting profiles from the same PREMISUT range.

Variants of the same family (½ circle conical-point needle, USP 6/0, 45 cm): it offers the HR12 Prime profile (SKU AMP541HR1260) for very reduced precision fields, the standard ribbed version of the HR13 (SKU AM541HR1360) and, if the protocol requires greater needle reach while maintaining the conical point, the HR16 Prime profile (SKU AMP541HR1660) or the higher profiles of the HR range (HR24, HR26 and HR30) in the same silk family.

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P541HR1360 together with the batch number for traceability in the operating theatre and store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

P541HR1360

Product line

PREMISUT Prime (premium range)

Material

100% natural silk (fibroin from Bombyx mori), braided multifilament

Coating

Wax and silicone

Thread structure

Braided (multifilament), Prime non-grooved finish

Absorption type

Non-absorbable; gradual encapsulation, wound support for more than 3 months

Metric gauge (EP)

0.7

Thread diameter

0.070 – 0.099 mm (USP Pharmacopoeia, non-absorbable suture)

Thread length

45 cm (single strand)

Thread colour

Black non-ribbed

Needle shape

½ circle (1/2 circular), cylindrical body

Tip type

Taperpoint conical (non-cutting)

Needle size

13 mm (HR13 Prime profile)

Swaged

1 needle / 1 suture per unit

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Presentation

Box of 12 units (individual sterile sachets); minimum order 30 boxes

Minimum order

30 boxes

Indications

Soft tissue approximation, ligatures, ophthalmology, microsurgery and skin surgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

Medida de aguja

HR 13

Usp

6/0

Color

Black

Medida de hilo

45 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Silk Suture PREMISUT Prime 1/2 Circle Taper Point HR13 (13 mm) · USP 6/0 (EP 0.7) · Black Braided Thread 45 cm · Non-Absorbable · Box of 12 units (Ref. P541HR1360)”

Your email address will not be published. Required fields are marked *