Description
The Silk Suture PREMISUT Prime HR13 is the reference in the premium range of non-absorbable silk from Cahnos for the professional who demands a natural-origin thread with exceptional handling, reliable knotting and predictable clinical behaviour. It combines a 100% natural braided silk strand in black, coated with wax and silicone, in USP 6/0 gauge and 45 cm of thread, mounted on a ½ circle needle with cylindrical body and conical Taperpoint point of 13 mm (HR13 profile). The Prime quality provides precision sharpening, non-ribbed finish, batch-to-batch consistency and full traceability, being the usual choice in ophthalmology departments, skin surgery, microsurgery and B2B purchasing and tendering centres.
Technical explanation of the material and procedure
Surgical silk is a natural protein fibre (fibroin from the cocoon of Bombyx mori) processed to remove natural waxes and gums and presented in a braided multifilament construction, coated with a mixture of wax and silicone. This coating reduces capillarity and friction when passing through tissue, improves handling and favours knot seating (recommended knotting technique 2 = 1 = 1 = 1), one of the most valued qualities of surgical silk.
Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The HR13 needle of 13 mm features a ½ circle curvature with cylindrical body and conical point (Taperpoint): the point separates the fibres without cutting them, achieving atraumatic penetration and minimal trauma to the puncture bed, making it especially suitable for soft, lax, well-vascularised or delicate tissues. The USP 6/0 gauge (metric EP 0.7) is one of the finest in the range, ideal for very delicate planes in ophthalmology and skin surgery, and the black colour ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable. Compliant with USP/EP Pharmacopoeia and with CE marking (MDR).
Technical specifications
Data verified according to the technical data sheet and instructions for use of the PREMISUT Prime range.
General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Factory reference | P541HR1360 |
| SKU Cahnos | AMP541HR1360 |
| Thread material | 100% natural silk (Bombyx mori fibroin), braided multifilament |
| Thread structure | Braided (multifilament), non-grooved surface (Prime) |
| Coating | Wax and silicone (anti-capillarity, low tissue drag) |
| Absorption type | Non-absorbable; gradual encapsulation, support for more than 3 months |
| Gauge / USP size | USP 6/0 (metric EP 0.7) |
| Approximate thread diameter | 0.070 – 0.099 mm (USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (single strand) |
| Thread colour | Black non-ribbed (high visibility) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Taperpoint conical (non-cutting) |
| Needle size | HR13 (13 mm) |
| Swaged | 1 needle / 1 thread of 45 cm per unit |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order 30 boxes |
| Indications | Soft tissue approximation, ligatures, ophthalmology, microsurgery and skin surgery |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia; CE marking (MDR) |
Gauge equivalence according to USP/EP Pharmacopoeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 6/0 (this product) | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1.0 | 0.10 – 0.149 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
Family PREMISUT Prime – Silk, ½ circle needle, cylindrical body conical point (HR profile), USP 6/0
| Needle profile | USP size | Colour | Thread (cm) | References |
| HR12 Prime (taper point, 12 mm) | 6/0 | Black | 45 | P541HR1260 / AMP541HR1260 |
| HR13 Prime (conical point, 13 mm) · this product | 6/0 | Black | 45 | P541HR1360 / AMP541HR1360 |
| HR13 standard ribbed (conical point, 13 mm) | 6/0 | Black | 45 | 541HR1360 / AM541HR1360 |
| HR16 Prime (taper point, 16 mm) | 6/0 | Black | 45 | P541HR1660 / AMP541HR1660 |
Equivalences and cross-references
The reference P541HR1360 corresponds to the official nomenclature of the PREMISUT Prime range (P = Prime quality; 541 = black 45 cm thread; HR = ½ circle needle with cylindrical body and conical point; 13 = 13 mm; 60 = USP 6/0 gauge) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. This needle geometry (HR13, conical point, USP 6/0, black 45 cm strand) is only safely interchangeable within the PREMISUT system itself.
There is no manufacturer-validated equivalence table that cross-references this specific configuration (black braided silk, ½ circle conical-point HR13 needle of 13 mm, USP 6/0 gauge and 45 cm strand) with codes from other commercial houses; consult the technical department of Cahnos before use in tendering or direct substitution. Non-absorbable black braided silk is one of the most standardised natural suture families on the market, with homologous lines of ½ circle and conical-point needles that must be reviewed property by property (material, USP/metric gauge, curvature, conical-point family, needle size and length —tolerance ±1 mm for needles ≥ 10 mm—, thread length, colour, coating and CE/MDR regulatory classification) before any substitution: B. Braun/Aesculap SILKAM®, Ethicon (J&J MedTech) MERSILK® / PERMA-HAND™ Silk, Medtronic Sofsilk™, DemeTECH DemeSILK™, Assut Assusilk®, Laboratorio Aragó, Lorca Marín, Unilene and Serag-Wiessner, among others. Always verify reference by reference and confirm each manufacturer’s IFU before use in a surgical protocol.
Selection tips and variants of interest
Tissue to suture: the USP 6/0 gauge (metric EP 0.7) is the microsurgery choice for very delicate planes —fine facial skin, eyelids, mucous membranes, ophthalmology and low-tension soft tissues— where the fine diameter minimises tissue reaction. The HR13 conical-point needle separates the fibres without cutting them, making it especially suitable in lax and well-vascularised tissues where minimal puncture trauma is sought; for firm and poorly distensible tissues, consider reverse-cutting profiles from the same PREMISUT range.
Variants of the same family (½ circle conical-point needle, USP 6/0, 45 cm): it offers the HR12 Prime profile (SKU AMP541HR1260) for very reduced precision fields, the standard ribbed version of the HR13 (SKU AM541HR1360) and, if the protocol requires greater needle reach while maintaining the conical point, the HR16 Prime profile (SKU AMP541HR1660) or the higher profiles of the HR range (HR24, HR26 and HR30) in the same silk family.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P541HR1360 together with the batch number for traceability in the operating theatre and store below 30 °C, away from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.