Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture PREMISUT | 3/8 Circle Reverse Cutting Triangular Point Needle DS30 (30 mm) | USP 2/0 Gauge | Colourless Grooved Thread 75 cm | Box of 12 units (Ref. P1L22DS3020)

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) in Prime quality, from the PREMISUT range, with a ⅜ circle needle with 30 mm reverse cutting triangular point (DS30), USP 2/0 gauge and a 75 cm colourless grooved thread. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, with minimal tissue reaction and excellent knot security, it is indicated for tissue approximation, ligatures and ophthalmic surgery. Reference P1L22DS3020, presentation in a box of 12 units with B2B conditions for hospitals, clinics and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L22DS3020

Description

1. Commercial Introduction

The Prime Absorbable Multifilament PGLA (Polyglactin 910) Suture from the PREMISUT range is the reference solution for operating theatre services, ophthalmic clinics, purchasing centres and distributors seeking a high-performance synthetic absorbable thread with exceptional handling and fully predictable clinical behaviour. This presentation incorporates a ⅜ circle needle with a 30 mm reverse cutting triangular point (DS30), USP 2/0 gauge and a 75 cm colourless grooved thread, an ideal combination for tissue approximation, ligatures and ophthalmic surgery. It is supplied in a box of 12 units, sterile and ready for immediate use in hospitals, private clinics and surgical material purchasing centres.

2. Technical Explanation

Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, configured in a braided multifilament structure coated with a grooved finish. This architecture favours smooth thread sliding through tissue, offers excellent handling and guarantees great knot security, even in working gauges such as USP 2/0.

Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid and lactic acid, substances that the body metabolises without causing significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing. The ⅜ circle needle with reverse cutting triangular point (reverse cutting) penetrates firm, non-compliant tissues with controlled trauma and no tearing, making it especially suitable for ophthalmic surgery, ligatures and tissue approximation. The colourless colour minimises the visibility of the strand on the surgical bed, highly valued in procedures where aesthetic discretion is sought. The product is supplied sterile by ethylene oxide, is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Brand / Range PREMISUT (Prime quality)
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided and coated multifilament (grooved)
Gauge USP 2/0 (metric 3)
Thread colour Colourless (violet on request)
Thread length 75 cm
Needle shape 3/8 circle
Tip type Reverse cutting triangular (reverse cutting)
Needle size DS 30 mm (Prime)
Sterilisation Ethylene oxide (EtO), single-use
Presentation Box of 12 units
Reference (SKU) P1L22DS3020

3.2. Absorption profile and tensile strength retention

Period Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56 – 72 days by hydrolysis

Minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.

3.3. Size equivalence

USP size Metric size Approximate diameter
2/0 3 0.30 – 0.349 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This Prime PGLA suture is equivalent in chemical composition, absorption profile (56-72 days) and tensile strength retention to the main international commercial ranges:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided coated polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ⅜ circle needles (DS series)

Within the Cahnos catalogue, the violet version of this same configuration (DS 30 mm needle, USP 2/0, 75 cm) corresponds to reference P1L12DS3020, and the double strand 2×75 cm presentation in violet to P1L12RDS3020.2. The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) offers an excellent balance between initial strength and handling for soft tissues of medium tension: skin, subcutaneous tissue, mucosa, fascia and ligatures. The ⅜ circle needle with 30 mm reverse cutting triangular point is especially recommended for firm, non-compliant tissues, where a clean and controlled needle passage is required, including microsurgery and ophthalmic surgery. The colourless thread provides maximum aesthetic discretion; if you prefer greater visibility on the surgical field, request the violet version.

Variants of interest in the same DS30 family:

  • P1L12DS3020: PGLA Prime, DS30, USP 2/0, violet, 75 cm (field-detectable strand).
  • P1L12RDS3020.2: PGLA Prime, DS30, USP 2/0, violet, double strand 2×75 cm.
  • P1L12DS3030: PGLA Prime, DS30, USP 3/0, violet, 75 cm (finer gauge).
  • P1L28DS3010: PGLA Prime, DS30, USP 0, colourless, 75 cm.
  • P1L12DS3620: PGLA Prime, DS36, USP 2/0, violet, 75 cm (longer needle).
  • AMP112DS3010: alternative in polyglycolic acid (PGA) with 60-90 day absorption.

If you need a longer retention profile (180-210 days) or a monofilament thread, consider the polydioxanone (PDO) family. All references are supplied in boxes of 12 units; consult the Cahnos technical-commercial team for minimum order and special B2B conditions by volume. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight.

Additional information

Reference

P1L22DS3020

Brand

PREMISUT

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Multifilament braided coated (fluted)

USP size

2/0 (metric 3)

Thread diameter

0.30 – 0.349 mm

Thread colour

Colourless (violet on request)

Needle type

Triangular reverse cutting point (reverse cutting)

Needle size

DS 30 mm (Prime)

Sterilisation

Ethylene oxide (EtO), single-use

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Medida de aguja

DS 30

Usp

2/0

Color

Colourless, Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture PREMISUT | 3/8 Circle Reverse Cutting Triangular Point Needle DS30 (30 mm) | USP 2/0 Gauge | Colourless Grooved Thread 75 cm | Box of 12 units (Ref. P1L22DS3020)”

Your email address will not be published. Required fields are marked *