We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Prime PGLA Polyglactin 910 Absorbable Multifilament Suture, ⅜ Circle Precision Reverse Cutting Triangular Needle XDS11 mm, USP Gauge 6/0, Undyed, 45 cm (Ref. P1L21XDS1160)

Original price was: 64,90 €.Current price is: 55,80 €.

Absorbable multifilament Polyglactin 910 (PGLA) suture from the Prime range, with a ⅜ circle needle with precision reverse cutting triangular point and square body of 11 mm (XDS11). USP gauge 6/0, undyed non-ribbed thread of 45 cm, sterilised by ethylene oxide. Absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 30 % at 4. Minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in box of 12 units. Reference P1L21XDS1160.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L21XDS1160

Description

1. Commercial Introduction

The Prime PGLA Polyglactin 910 Absorbable Multifilament Suture is the trusted choice for the professional seeking the optimal balance between handling, knot security and controlled absorption. Presented with a ⅜ circle needle with precision reverse cutting triangular point and square body of 11 mm (XDS11), it is designed for procedures that require clean penetration and minimal tissue resistance, both in tissue approximation and in ligatures and ophthalmic surgery.

Manufactured under Prime quality standards (PREMISUT) and available for wholesale distribution, this reference offers predictable performance and excellent value for money for clinics, hospitals, ophthalmic centres and purchasing groups.

2. Technical Explanation

It is a synthetic absorbable braided (multifilament) suture made from polyglactin 910, a copolyester composed of 90 % glycolide and 10 % L-lactide. Its absorption mechanism is hydrolysis, a predictable process that does not depend on tissue enzymes and ensures a constant mass loss between 56 and 72 days.

The undyed, non-ribbed thread offers a regular surface that facilitates passage through tissue and firm knot anchorage. The XDS11 needle with precision reverse cutting triangular point (extra-long cutting edge) and square body is ideal for resistant tissues such as skin and mucous membranes, providing controlled penetration with minimal bed injury. It is supplied sterile by ethylene oxide, for single use and not for re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Characteristic Detail
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Structure Braided multifilament, non-grooved
Thread colour Colourless (violet on demand)
USP size 6/0 (metric 0.7)
Thread length 45 cm
Needle shape ⅜ circle
Needle tip Triangular precision reverse cutting (extra-long cutting edge)
Needle body Square
Needle size XDS 11 mm
Quality Prime (PREMISUT)
Sterilisation Ethylene oxide (EtO)
Presentation Box of 12 units
Reference P1L21XDS1160

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 56 – 72 days
Tensile strength at 2 weeks 75 %
Tensile strength at 3 weeks 50 %
Tensile strength at 4 weeks 30 %
Tissue reaction Minimal

3.3. Size equivalence

USP size Approximate diameter Metric
6/0 0.07 – 0.099 mm 0.7

Price per box of 12 units. See B2B terms for orders in multiples.

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used absorbable multifilament material in the surgical market and its clinical performance is comparable to that of braided polyglactin 910 sutures from the main international manufacturers: Vicryl and Vicryl Plus (Ethicon), Safil (B. Braun) and Polysorb (Medtronic), all with equivalent absorption and strength retention profiles. In the Laboratorio Aragó catalogue, polyglactin 910 corresponds to the 4xxxx code range with equivalent needle tables.

In the Cahnos catalogue, the warehouse version of this same presentation corresponds to reference AMP1L21XDS1160. Notable alternatives of the same material with other configurations include: P1L21XDS1150 (same XDS11 needle in USP gauge 5/0), P1L21XDS1360 (XDS13 needle, USP 6/0), P1L21XDS1640 (XDS16 needle, USP 4/0), P1L21XDS1930 (XDS19 needle, USP 3/0) and P1L21XDS1950 (XDS19 needle, USP 5/0). For double-needle presentations, P1L11XDS1160-2 may be considered, and for faster reabsorption applications, the Rapid PGLAR line from the same family.

5. Selection tips and variants of interest

USP gauge 6/0 (metric 0.7) is indicated for very fine and delicate tissues, such as skin, mucosa, conjunctiva or eyelids. If greater initial strength is required, consider gauges 5/0 and 4/0 from the same Prime line.

The ⅜ circle needle with precision reverse cutting point and square body is especially recommended for firm or difficult-to-penetrate tissues, where control and high puncture capacity without tearing are required. For larger surgical fields, the XDS13, XDS16 and XDS19 needles from the same family are available.

In undyed colour it is preferable when maximum aesthetic discretion is sought; the violet version facilitates thread visibility during suturing and is available on demand. If your protocol requires longer tensile support, consider the absorbable monofilament polydioxanone lines; if, on the contrary, you seek faster absorption, consult the Rapid polyglactin 910 range. Contact our technical-commercial team to optimise your order by boxes and benefit from special B2B conditions.

Additional information

Material

Polyglactin 910 (90 % glycolide / 10 % L-lactide)

Structure

Braided multifilament, non-grooved

USP size

6/0 (metric 0.7)

Colour

Colourless (violet on request)

Needle tip

Precision reverse cutting triangular (extra-long cutting edge)

Needle body

Square

Quality

Prime (PREMISUT)

Sterilisation

Ethylene oxide (EtO)

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Reference

P1L21XDS1160

Medida de aguja

XDS 11

Usp

6/0

Color

Colourless, Violet

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Prime PGLA Polyglactin 910 Absorbable Multifilament Suture, ⅜ Circle Precision Reverse Cutting Triangular Needle XDS11 mm, USP Gauge 6/0, Undyed, 45 cm (Ref. P1L21XDS1160)”

Your email address will not be published. Required fields are marked *