We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Prime · 3/8 Circle Triangular Needle Precision Reverse Cutting XDS26 mm · USP 3/0 · Undyed · 70 cm

Original price was: 70,00 €.Current price is: 50,00 €.

Absorbable multifilament PGLA (Polyglactin 910) suture from the Prime range with a ⅜ circle needle, precision reverse cutting triangular point and square body of 26 mm (XDS26). USP 3/0 gauge, undyed non-grooved thread of 70 cm. Absorption by hydrolysis between 56 and 72 days, with excellent tensile strength and knot tying security and minimal tissue reaction. Sterilised by ethylene oxide. Indicated for tissue approximation, ligatures, ophthalmic surgery and plastic-cosmetic procedures. Presentation in box of 12 units. Ref. P1L28XDS2630.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L28XDS2630

Description

The Absorbable Multifilament Suture PGLA Polyglactin 910 Prime is the technical choice of professionals seeking a synthetic absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. Its ⅜ circle needle with precision reverse cutting triangular point and square body (model XDS 26 mm) is designed for tissue approximation in general surgery, ligatures, ophthalmic surgery and plastic and cosmetic surgery, where a clean, controlled and tear-free needle passage is required.

Technical explanation

This suture is manufactured from Polyglactin 910 (PGLA), a copolymer composed of 90% glycolide and 10% L-lactide, which is reabsorbed by hydrolysis over a predictable period of 56 to 72 days. Its braided, non-grooved multifilament structure provides high flexibility and a uniform contact surface, resulting in balanced tensile strength and great security in knot tying.

The ⅜ circle needle with precision reverse cutting triangular point and square body (XDS Prime) penetrates tissue with a controlled cutting effect, highly valued in skin and plastic-cosmetic tissues, as it reduces tearing and facilitates suturing of tension areas. The thread, undyed in colour, offers maximum discretion on the surgical field and is reabsorbed uniformly, without depending on tissue enzymes, ensuring a predictable clinical evolution of the sutured tissues.

Technical specifications

Material Polyglactin 910 (PGLA): copolymer 90% glycolide / 10% L-lactide
Structure Braided multifilament, non-grooved
Needle shape ⅜ circle
Needle tip Extra-long precision reverse-cutting triangular
Needle body Square
Needle size XDS 26 mm (Prime)
USP size 3/0
Thread length 70 cm
Suture colour Colourless
Quality Prime
Sterilisation Ethylene oxide (sterile presentation)
Presentation Box of 12 units
Reference P1L28XDS2630

Tensile strength retention profile

Period Strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Absorption profile

Absorption type Hydrolysis
Estimated duration 56 – 72 days
Tissue reaction Minimal
Knot tying Excellent safety

Main indications: approximation of soft tissues, ligatures, ophthalmic surgery and plastic and aesthetic surgery (tension areas and subcutaneous tissue).

Equivalences and cross-references

Polyglactin 910 is the clinical reference material for medium-duration absorbable braided sutures. This reference behaves as a functional equivalent of the general-use braided polyglactin 910 sutures on the market (ranges such as Vicryl from Ethicon/Johnson & Johnson, Polysorb from Medtronic and similar), providing in this case an extra degree of precision thanks to the XDS Prime needle with square body.

In the Cahnos catalogue, the stock version of this same presentation corresponds to reference AMP1L28XDS2630. As alternatives of the same material with other needle or gauge configurations, the following stand out:

Reference Description
P1L18XDS3020 PGLA Prime 3/8 circle XDS, USP 2/0, violet, 70 cm
P1L21XHS1640 PGLA Prime ½ circle XHS16, USP 4/0, undyed, 45 cm
1L28HR1730 PGLA ½ circle cylindrical HR17, USP 3/0, undyed, 70 cm
1L18HS2230 PGLA ½ circle triangular HS22, USP 3/0, violet, 70 cm

Selection tips and variants of interest

  • USP 3/0 gauge is indicated for tissues with moderate tension: skin, subcutaneous tissue, fascia and soft tissue in general.
  • The precision reverse cutting needle with square body is especially recommended in plastic and cosmetic surgery techniques, where the needle passage must be clean and tear-free.
  • If greater visibility in the field is required, the same reference can be requested in violet; the undyed version is chosen when maximum aesthetic discretion is sought.
  • In the Cahnos catalogue, other thread lengths are available (45, 70 and 75 cm), gauges from 6/0 to 2/0, double needle versions and other needle geometries (DS, XHS, XNS and cylindrical types).
  • Price per box of 12 units. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA) – copolymer 90% glycolide / 10% L-lactide

Structure

Braided multifilament, non-grooved

Needle tip

Extra-long precision reverse-cutting triangular

Needle body

Square

Needle size

XDS 26 mm (Prime)

Sterilisation

Ethylene oxide

Tissue reaction

Minimal

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures, ophthalmic surgery and plastic-cosmetic surgery

Reference

P1L28XDS2630

Medida de aguja

XDS 26

Usp

3/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Prime · 3/8 Circle Triangular Needle Precision Reverse Cutting XDS26 mm · USP 3/0 · Undyed · 70 cm”

Your email address will not be published. Required fields are marked *