Description
1. Commercial Introduction
The multifilament absorbable suture of polyglactin 910 (PGLA), reference 1L12HR4510 from the Premisut range, is the reference surgical closure solution for the professional who demands a flexible, resistant thread with totally predictable absorption in the operating theatre. Its ½ circle needle with cylindrical body and taper point of 45 mm (HR 45) penetrates soft tissues separating the fibres without cutting them, which minimises trauma and makes it especially suitable for tissue approximation, ligatures and ophthalmic surgery.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money for B2B supply to hospitals, ophthalmic clinics and purchasing centres. It is presented in a box of 12 units with a minimum order of 30 boxes, which guarantees continuous and traceable supply for your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, comfortable sliding and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. The thread maintains 75% of its tensile strength at 2 weeks, 50% at 3 weeks and 30% at 4 weeks, while the tissue recovers its own resistance: an ideal profile for tissues requiring support for 2 to 4 weeks of healing. The ½ circle needle with cylindrical body and taper point penetrates separating the fibres without cutting them, minimising trauma in soft and friable tissues, while the violet colouration of the thread guarantees optimal visibility on the surgical field. The product is supplied sterile by ethylene oxide, single-use and without possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 1L12HR4510
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L12HR4510 |
| Range / Quality | Premisut, Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet (also available colourless) |
| Gauge | USP 0 (metric 3.5) |
| Thread length | 75 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 45 mm (HR 45) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56-72 days |
| Sterilisation | Ethylene oxide; single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days, by hydrolysis |
Excellent tensile strength and knot tying, with a totally predictable absorption rate and minimal tissue reaction.
3.3. Presentation and ordering conditions
| Value | Value |
|---|---|
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most widespread synthetic absorbable materials on the European market. This reference is clinically comparable, by composition, absorption profile and tension retention, to the braided multifilament sutures of the main manufacturers:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910, violet) |
| Assut | Assucryl 910 (polyglactin 910) |
Within the Cahnos catalogue, its direct equivalent in superior quality with the same needle and gauge configuration is reference P1L12HR4510 (Prime quality), and the alternative in polyglycolic acid with the same HR 45 mm needle geometry is reference AM112HR4510 (absorption 60-90 days). The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during a 2 to 4 week healing period. The taper point (HR) separates the fibres without cutting them and is ideal for soft tissues; if the tissue is very friable, the most atraumatic option is the blunt point (HRN), while for firm and dense tissues the trocar point (HRT) is recommended.
| Reference | Variant |
|---|---|
| 1L12HR4510 | PGLA USP 0, taper point HR 45 mm, violet, 75 cm (current product) |
| P1L12HR4510 | Same configuration in Prime quality |
| 1L12HR4520 | PGLA USP 2/0, taper point HR 45 mm, violet, 75 cm |
| 1L12HR4810 | PGLA USP 0, conical point HR 48 mm, violet, 75 cm |
| 1L13HR4810 | PGLA USP 0, taper point HR 48 mm, violet, 90 cm |
| 1L18HR4501 | PGLA USP 1, taper point HR 45 mm, violet, 70 cm |
| 1L15HR48L10 | PGLA USP 0, taper point HR 48 mm, violet, 150 cm loop |
| AM112HR4510 | PGA USP 0, taper point HR 45 mm, violet, 75 cm (absorption 60-90 days) |
For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in a box of 12 units; the minimum order is 30 boxes to guarantee continuous supply for your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.