We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime Ribbed USP 2 | 1/2 Circle Cylindrical Needle HR 40 mm Conical Point | Violet | 2 strands of 90 cm

49,55 €

Absorbable multifilament suture of polyglactin 910 (PGLA) Prime Ribbed from Premisut, with a ½ circular cylindrical needle with conical point (Taperpoint) HR 40 mm, USP 2 gauge and two 90 cm strands in violet with ribbed finish. Absorption by hydrolysis between 56 and 72 days with tensile strength retention of 75% at 2 weeks. Sterile by ethylene oxide. Reference P1L13HR4002.2, presentation in boxes of 12 units and minimum order of 30 boxes.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L13HR4002.2

Description

1. Introduction

The absorbable multifilament suture of polyglactin 910 (PGLA) Prime Ribbed from the Premisut range is the reference choice in the operating theatre for professionals seeking reliable, predictable, high-quality performance in the approximation of soft tissues, ligatures and ophthalmic surgery. Its presentation with two 90 cm strands and a ½ circular cylindrical needle with conical point HR 40 mm optimises performance per unit, reduces material handling and facilitates stock management in the healthcare facility.

Manufactured under strict quality standards, this suture combines minimal tissue reaction with excellent tensile strength and optimal knot security, ensuring consistency and clinical results in every procedure. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes for continuous professional supply.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. It is configured in a braided multifilament structure with a ribbed finish (Prime Ribbed), which provides a regular surface that favours the sliding of the strand through tissue, excellent handling and firm, secure knot tying.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. This profile makes it suitable for tissues requiring wound support during the first weeks of healing.

The ½ circle needle has a cylindrical body and a conical point (Taperpoint) of 40 mm. This geometry allows it to pass through delicate tissues with minimal trauma, being especially indicated in ophthalmic surgery, tissue approximation and ligatures, where precision and atraumatic performance are decisive. The product is supplied sterile by ethylene oxide.

3. Technical Specifications

Characteristic Specification
Material Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide)
Thread structure Braided multifilament with ribbed finish (Prime Ribbed)
Gauge USP 2
Colour Violet
Needle Half-circle, cylindrical body, conical point (Taperpoint)
Needle size HR 40 mm
Thread length 2 threads of 90 cm
Absorption mechanism Hydrolysis
Sterilisation Ethylene oxide
Presentation Box of 12 units
Reference P1L13HR4002.2

Tensile strength retention profile:

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market (polyglactin 910-type material), common in general and specialised surgery. Within the Cahnos catalogue, its direct equivalent in single strand is reference P1L13HR4002 (1 strand of 90 cm, same gauge, same needle and same colour), ideal when an individual format is preferred.

To configure the complete operating theatre range, it is recommended to combine this reference with the following variants of the same family:

Reference Variant
P1L13HR4002.2 PGLA Prime Ribbed USP 2, HR 40 mm needle, violet, 2 x 90 cm (current product)
P1L13HR4002 PGLA Prime Ribbed USP 2, HR 40 mm needle, violet, 1 x 90 cm
P1L13HR4001 PGLA Prime Ribbed USP 1, HR 40 mm needle, violet, 1 x 90 cm
P1L13HR4502.2 PGLA Prime Ribbed USP 2, HR 45 mm needle, violet, 2 x 90 cm
P1L13HR4802 PGLA Prime USP 2, HR 48 mm needle, violet, 1 x 90 cm
P1L23HR4002 PGLA Prime Ribbed USP 2, HR 40 mm needle, colourless, 1 x 90 cm

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge depending on the anatomical area. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks.

  • The 2 strands of 90 cm format is especially cost-effective in procedures that consume several stitches or in high-volume surgical programmes.
  • If you need longer strength retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days.
  • For tissues with faster absorption needs, consult the range of fast-absorbing polyglactin 910 (PGLAR type).
  • All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility.

Additional information

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide)

Structure

Braided multifilament with ribbed finish (Prime Ribbed)

Gauge

USP 2

Needle

1/2 circle, cylindrical body, taper point (Taperpoint)

Thread length

2 threads of 90 cm

Absorption mechanism

Hydrolysis

Absorption time

56-72 days

Sterilisation

Ethylene oxide

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Reference

P1L13HR4002.2

Medida de aguja

HR 40, RHR 40

Usp

2

Color

Violet

Medida de hilo

2 × 90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime Ribbed USP 2 | 1/2 Circle Cylindrical Needle HR 40 mm Conical Point | Violet | 2 strands of 90 cm”

Your email address will not be published. Required fields are marked *