Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 20 mm | USP Gauge 4/0 (Metric 1.5) | Violet Thread 75 cm | Ref. P1L12HR2040 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) from the Premisut Prime range, with a ½ circle needle, cylindrical body and 20 mm (HR 20) taperpoint conical point, USP 4/0 (metric 1.5) gauge and 75 cm violet braided thread. Synthetic copolymer of 90 % glycolide and 10 % L-lactide, with predictable hydrolysis absorption between 56 and 72 days and tensile strength retention of 75 % at 2 weeks, 50 % at 3 weeks and 30 % at 4 weeks. Minimal tissue reaction, excellent handling and maximum knot tying security for approximation of soft tissues, ligatures and ophthalmic surgery. Sterile by ethylene oxide, single-use. Reference P1L12HR2040, presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L12HR2040

Description

The absorbable multifilament suture of Polyglactin 910 (PGLA) from the Premisut Prime range, reference P1L12HR2040, is the choice of the professional seeking a resorbable surgical suture with predictable behaviour, excellent handling and high knot security. Its ½ circle needle, cylindrical body and 20 mm (HR 20) taperpoint conical point guarantee a clean and atraumatic passage, an essential quality in delicate tissues, ligatures and ophthalmic surgery.

The violet thread of 75 cm, USP 4/0 (metric 1.5) gauge, offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic, absorbable, sterile and single-use medical device, with an excellent price-quality ratio for B2B supply to operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes to ensure the continuous supply of your centre.

What it is and how this Polyglactin 910 suture works

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved and coated finish. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling, low memory and a firm and secure knot seating, even in fine gauges such as USP 4/0.

Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing, while the tissue recovers its own resistance.

The ½ circle needle with cylindrical body and taperpoint conical point separates the fibres without cutting effect, minimising injury to the tissue bed, which is why it is especially indicated in ophthalmic surgery and in soft tissues. The product is supplied sterile by ethylene oxide, is single-use and does not allow re-sterilisation.

Technical specifications

General characteristics of reference P1L12HR2040

Reference (SKU) P1L12HR2040
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided, coated and fluted multifilament
Gauge USP 4/0 (metric 1.5)
Colour Violet (also available colourless in the family)
Needle shape ½ circle, cylindrical body
Needle tip Conical taperpoint (HR 20), atraumatic
Needle size 20 mm
Thread length 75 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (single-use)
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order of 30 boxes)

Absorption and tensile strength retention profile

Implantation time Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days by hydrolysis

Complete absorption by hydrolysis between 56 and 72 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units; consult B2B conditions for volume orders.

Equivalences and cross-references

Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice and presents an absorption profile (56-72 days) and tensile strength retention equivalent to the braided lines of the main international manufacturers:

Manufacturer Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (absorbable polyglactin 910)
Assut Sutures Assucryl 910 (polyglactin 910)
DemeTECH Vitacryl (coated braided polyglactin 910)
Premisut range (Cahnos) Multifilament PGLA with ½ circle needle (HR series, ref. P1L12HR2040)

Within the Cahnos catalogue, its direct structural equivalent in the same PGLA family is reference P1L12HR2240 (cylindrical HR 22 mm needle, USP 4/0, violet, 75 cm) and, in the polyglycolic acid (PGA) family, reference AMP112HR2040 (cylindrical HR 20 mm needle, USP 4/0, violet, 75 cm), recommended when an absorption profile of 60 to 90 days is preferred. The brands cited belong to their respective manufacturers and are mentioned solely as a reference for equivalence; for a formal substitution of references, consult our technical-commercial department.

Selection tips and variants of interest

The USP 4/0 (metric 1.5) gauge is indicated for fine and low-tension tissues: skin, mucosa, subcutaneous tissue and delicate planes where aesthetic healing and the minimum possible trauma are sought. The ½ circle cylindrical needle with a 20 mm conical point is especially recommended in soft tissues, ligatures and ophthalmic surgery, where the passage of the needle must be clean and atraumatic.

Reference Variant of interest
P1L12HR2040 PGLA Prime, HR 20 mm, USP 4/0, violet, 75 cm (current reference)
P1L12HR2240 PGLA Prime, HR 22 mm, USP 4/0, violet, 75 cm (larger radius needle)
P1L12HR2030 PGLA Prime, HR 20 mm, USP 3/0, violet, 75 cm (finer gauge, maximum fineness)
P1L12HR2020 PGLA Prime, HR 20 mm, USP 2/0, violet, 75 cm (greater strength)
P1L12HR2030.2 PGLA Prime, HR 20 mm, USP 3/0, violet, 2×75 cm (double thread format)
AMP112HR2040 PGA alternative, HR 20 mm, USP 4/0, violet, 75 cm (absorption 60-90 days)

If you need a more prolonged strength retention (180-210 days) or a monofilament profile, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided, coated and fluted multifilament

USP size

4/0 (metric 1.5)

Colour

Violet (also available colourless)

Needle shape

½ circle, cylindrical body

Needle type

Conical taperpoint, atraumatic

Needle size

20 mm (HR 20)

Tensile strength

75 % at 2 weeks, 50 % at 3 weeks, 30 % at 4 weeks

Sterilisation

Ethylene oxide, single-use

Tissue reaction

Minimal

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Quality

Prime (Premisut range)

Reference

P1L12HR2040

Medida de aguja

HR 20

Usp

4/0

Color

Colourless, Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)