We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Prime – Needle 1/2 Circle Cylindrical Conical Point Taperpoint HR 40 mm – USP Size 2 – Violet Thread 90 cm – Ref. P1L13HR4002 (Box of 12 units)

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament PGLA (Polyglactin 910) Prime quality suture from the Premisut range, with ½ circle needle of cylindrical body and tapered Taperpoint point of 40 mm (HR40), USP 2 gauge and braided violet thread of 90 cm. Predictable absorption by hydrolysis in 56-72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction and optimal knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Reference P1L13HR4002, presentation in box of 12 units and minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L13HR4002

Description

1. Introduction

The absorbable multifilament PGLA (Polyglactin 910) Prime suture from the Premisut range is the reference choice in the operating theatre for professionals, hospitals, private clinics and purchasing centres seeking a high-performance synthetic thread with an excellent balance between quality and price. Mounted with a ½ circle needle, cylindrical body and tapered Taperpoint point of 40 mm (HR40), it is indicated for tissue approximation, ligatures and, notably, ophthalmic surgery, where precision, handling and fully predictable absorption are required.

Each unit is supplied sterile and ready to use, with the backing of Cahnos professional distribution for continuous hospital supply. It is presented in USP 2 gauge, violet thread of 90 cm and is marketed in boxes of 12 units under reference P1L13HR4002, with a minimum order of 30 boxes.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a ribbed finish gives it great flexibility, low memory and a contained coefficient of friction, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 2.

Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes it suitable for tissues that require wound support during the first 2 to 4 weeks of healing. The ½ circle needle with cylindrical body and tapered point (Taperpoint) separates the fibres without cutting them, minimising trauma to delicate structures. The violet colour guarantees optimal visibility of the thread in the surgical field. Sterile single-use product, with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference P1L13HR4002

Characteristic Specification
Reference (SKU) P1L13HR4002
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with ribbed finish (Prime Ribbed)
Gauge USP 2 (metric 5)
Thread colour Violet (also available in colourless)
Thread length 90 cm
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Taperpoint conical
Needle size 40 mm (HR 40 Prime)
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile

Period Remaining tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 30 % of initial tensile strength
Total absorption 56-72 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

This polyglactin 910 suture belongs to the family of synthetic braided absorbable sutures of medium absorption, clinically equivalent to the reference polyglactin 910 sutures on the international market. All share composition (90/10 copolymer), braided structure, ethylene oxide sterilisation and absorption by hydrolysis in the range of 56 to 72 days.

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided polyglactin 910, violet)
B. Braun Safil (braided polyglactin 910, violet)
Medtronic / Covidien Polysorb (absorbable braided range)
SMI Surgicryl (polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ½ circle cylindrical needles (TC/HR series)

Within the Cahnos catalogue, its direct equivalent in double format is reference P1L13HR4002.2 (2 threads of 90 cm, same gauge, same needle and same colour) and the alternative in colourless thread P1L23HR4002. To configure the complete operating theatre range, it is recommended to combine this reference with the following variants of the same family:

Reference Variant
P1L13HR4002 PGLA Prime USP 2, HR 40 mm needle, violet, 90 cm (current product)
P1L13HR4002.2 PGLA Prime Ribbed USP 2, HR 40 mm needle, violet, 2 x 90 cm
P1L13HR4001 PGLA Prime USP 1, HR 40 mm needle, violet, 90 cm
P1L13HS4002 PGLA Prime USP 2, HS 40 mm triangular reverse cutting needle, violet, 90 cm
P1L13HR4802 PGLA Prime USP 2, HR 48 mm needle, violet, 90 cm
AMP113HR4002 PGA Prime USP 2, HR 40 mm needle, violet, 90 cm (alternative in polyglycolic acid)

5. Selection tips and variants of interest

To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the necessary gauge depending on the anatomical area. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks. USP 2 gauge (metric 5) is indicated for tissues requiring greater initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The tapered Taperpoint point is ideal for soft tissues and delicate structures; for fibrous tissues or sclera, trocar or reverse cutting points are recommended.

  • P1L13HR4001: PGLA Prime USP 1, HR 40 mm needle, violet, 90 cm (smaller gauge for moderate tension).
  • P1L13HR4802: PGLA Prime USP 2, HR 48 mm needle, violet, 90 cm (needle with larger radius).
  • P1L13HS4002: PGLA Prime USP 2, HS 40 mm triangular needle, violet, 90 cm (reverse cutting point for firm tissues).
  • P1L18HR4002: PGLA Prime USP 2, HR 40 mm needle, violet, 70 cm (shorter thread).

If you need longer force retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days. For tissues with faster absorption needs, consult the range of fast-absorbing polyglactin 910 (PGLAR type) or polyglycolic acid (PGA). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Reference

P1L13HR4002

Brand

Premisut

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 2 (metric 5)

Needle body

Cylindrical

Needle tip

Taperpoint conical

Needle size

40 mm (HR 40 Prime)

Absorption mechanism

Hydrolysis (56-72 days)

Sterilisation

Ethylene oxide (EO), single-use

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 40

Usp

2

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Prime – Needle 1/2 Circle Cylindrical Conical Point Taperpoint HR 40 mm – USP Size 2 – Violet Thread 90 cm – Ref. P1L13HR4002 (Box of 12 units)”

Your email address will not be published. Required fields are marked *