We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime – ½ Circle Needle Cylindrical Body Taperpoint Conical Tip HR 36 mm – USP 0 Gauge – Undyed Grooved Thread 90 cm – Box of 12 units. Ref. P1L23HR3610

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of polyglactin 910 (PGLA) from the Prime range, with a ½ circle needle with cylindrical body and taperpoint conical tip of 36 mm (HR 36), USP 0 gauge and undyed grooved thread of 90 cm. Copolymer of 90% glycolide and 10% L-lactide, with predictable absorption by hydrolysis between 56 and 72 days and tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction and optimal knot security for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L23HR3610. Price per box of 12 units; minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L23HR3610

Description

Absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, reference P1L23HR3610, the professional solution your operating theatre needs for procedures that demand reliability, handling and fully predictable absorption. With a ½ circular needle with cylindrical body and taperpoint conical tip of 36 mm, USP 0 gauge and undyed grooved thread of 90 cm, it offers consistent clinical performance in tissue approximation, ligatures and ophthalmic surgery. Supplied in a box of 12 units, with a minimum order of 30 boxes, it constitutes a high-quality alternative with an excellent cost-performance ratio for hospitals, clinics, ophthalmologists and purchasing centres.

Technical product explanation

Polyglactin 910 (PGLA) is a biocompatible synthetic copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish provides great flexibility, low memory and a contained friction coefficient, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes the suture suitable for tissues that require wound support during the first 2 to 4 weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.

The ½ circular needle with cylindrical body and taperpoint conical tip (HR36) penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is especially recommended in ophthalmic surgery and in the approximation of soft tissues. The undyed colour of the thread avoids visual interference and is optimal in fields where a discreet and aesthetic suture is required. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

Technical specifications

Technical data sheet for reference P1L23HR3610

Characteristic Specification
Reference (SKU) P1L23HR3610
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 0 (metric 3.5)
Thread colour Colourless
Thread length 90 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Taperpoint conical
Needle size 36 mm (HR 36 Prime)
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56-72 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.

Equivalences and cross-references

Polyglactin 910 is one of the most well-established multifilament synthetic absorbable suture raw materials on the market. This reference from the Prime line is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines on the international market:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (braided polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range)
SMI Surgicryl (polyglactin 910)
Assut Assucryl 910
Laboratory Aragó Polyglactin 910 range with ½ circle cylindrical needles (TC/HR series)

Within the Cahnos catalogue, its direct equivalent in the same configuration (HR 36 mm needle, USP 0 gauge, 90 cm thread) is reference P1L13HR3610 in violet. In the polyglycolic acid (PGA) family, the equivalent of the same format and gauge is AMP123HR3610, with an absorption profile of 60 to 90 days. The equivalences indicated are for guidance only; for a formal substitution of references, consult our technical-commercial department.

Selection tips and variants of interest

USP 0 gauge offers an optimal balance between strength and fineness, indicated for soft tissues that require healing support of 2 to 4 weeks. The ½ circular needle with taperpoint conical tip is ideal for delicate tissues, with special application in ophthalmic surgery; if you need to penetrate firmer tissues (skin, fascia, sclera) consider reverse cutting or trocar points.

Reference Variant
P1L23HR3610 PGLA Prime USP 0, HR 36 mm needle, undyed, 90 cm (current product)
P1L13HR3610 PGLA Prime USP 0, HR 36 mm needle, violet, 90 cm (same configuration in violet)
P1L23HR3620 PGLA Prime USP 2/0, HR 36 mm needle, undyed, 90 cm (smaller gauge, delicate tissues)
P1L23HR3602 PGLA Prime USP 2, HR 36 mm needle, undyed, 90 cm (larger gauge, high tension)
P1L13HS3610 PGLA Prime USP 0, triangular reverse cutting needle HS 36 mm, violet (firm tissues)
AMP123HR3610 PGA Prime USP 0, HR 36 mm needle, undyed, 90 cm (absorption 60-90 days)
AMP2L23HR3610 PGLAR Polyglactin 910 Rapid, HR 36 mm needle, undyed, 90 cm (absorption 40-45 days)

If you need a longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to guarantee the continuous supply of your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 0 (metric 3.5)

Tip type

Taperpoint conical

Needle size

36 mm (HR 36 Prime)

Absorption mechanism

Hydrolysis, 56-72 days

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Minimum order

30 boxes

Indications

Tissue approximation, ligatures and ophthalmic surgery

Reference

P1L23HR3610

Medida de aguja

HR 36

Usp

0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime – ½ Circle Needle Cylindrical Body Taperpoint Conical Tip HR 36 mm – USP 0 Gauge – Undyed Grooved Thread 90 cm – Box of 12 units. Ref. P1L23HR3610”

Your email address will not be published. Required fields are marked *