Description
Absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, reference P1L23HR3610, the professional solution your operating theatre needs for procedures that demand reliability, handling and fully predictable absorption. With a ½ circular needle with cylindrical body and taperpoint conical tip of 36 mm, USP 0 gauge and undyed grooved thread of 90 cm, it offers consistent clinical performance in tissue approximation, ligatures and ophthalmic surgery. Supplied in a box of 12 units, with a minimum order of 30 boxes, it constitutes a high-quality alternative with an excellent cost-performance ratio for hospitals, clinics, ophthalmologists and purchasing centres.
Technical product explanation
Polyglactin 910 (PGLA) is a biocompatible synthetic copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish provides great flexibility, low memory and a contained friction coefficient, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes the suture suitable for tissues that require wound support during the first 2 to 4 weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ½ circular needle with cylindrical body and taperpoint conical tip (HR36) penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is especially recommended in ophthalmic surgery and in the approximation of soft tissues. The undyed colour of the thread avoids visual interference and is optimal in fields where a discreet and aesthetic suture is required. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
Technical specifications
Technical data sheet for reference P1L23HR3610
| Characteristic | Specification |
| Reference (SKU) | P1L23HR3610 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Colourless |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint conical |
| Needle size | 36 mm (HR 36 Prime) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.
Equivalences and cross-references
Polyglactin 910 is one of the most well-established multifilament synthetic absorbable suture raw materials on the market. This reference from the Prime line is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines on the international market:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (TC/HR series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (HR 36 mm needle, USP 0 gauge, 90 cm thread) is reference P1L13HR3610 in violet. In the polyglycolic acid (PGA) family, the equivalent of the same format and gauge is AMP123HR3610, with an absorption profile of 60 to 90 days. The equivalences indicated are for guidance only; for a formal substitution of references, consult our technical-commercial department.
Selection tips and variants of interest
USP 0 gauge offers an optimal balance between strength and fineness, indicated for soft tissues that require healing support of 2 to 4 weeks. The ½ circular needle with taperpoint conical tip is ideal for delicate tissues, with special application in ophthalmic surgery; if you need to penetrate firmer tissues (skin, fascia, sclera) consider reverse cutting or trocar points.
| Reference | Variant |
| P1L23HR3610 | PGLA Prime USP 0, HR 36 mm needle, undyed, 90 cm (current product) |
| P1L13HR3610 | PGLA Prime USP 0, HR 36 mm needle, violet, 90 cm (same configuration in violet) |
| P1L23HR3620 | PGLA Prime USP 2/0, HR 36 mm needle, undyed, 90 cm (smaller gauge, delicate tissues) |
| P1L23HR3602 | PGLA Prime USP 2, HR 36 mm needle, undyed, 90 cm (larger gauge, high tension) |
| P1L13HS3610 | PGLA Prime USP 0, triangular reverse cutting needle HS 36 mm, violet (firm tissues) |
| AMP123HR3610 | PGA Prime USP 0, HR 36 mm needle, undyed, 90 cm (absorption 60-90 days) |
| AMP2L23HR3610 | PGLAR Polyglactin 910 Rapid, HR 36 mm needle, undyed, 90 cm (absorption 40-45 days) |
If you need a longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to guarantee the continuous supply of your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.